Plan Review Stops For Permit 08070715 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-17 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-17 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-10-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-03 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-03 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-08-15 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-08-15 |
Time |
06:56 |
Sent To |
PC |
|
Notes |
2008-09-29 07:36:28 | | | BUILDING PLAN REVIEW | | PERMIT: 08070715 | | ADD: 1255 PBL BLVD | | CONT: DAVCAO RETAIL SERVICES | | TEL: (214)706-4029 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 8-15-08 | | REVIEW 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. SHOW THIS | | INFORMATION ON THE PLANS. | | | | 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. | | | | 5) PLEASE GIVE MORE DETAIL AS TO THE TYPE OF EXAM WHICH | | WILL BE PERFORMED. ADDITIONAL INFORMATION IS REQUIRED | | 106.1.2* | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-10-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-23 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-23 |
Time |
15:16 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-10-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-08 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-07 |
Time |
11:24 |
Sent To |
|
|
Notes |
2008-10-07 12:57:25 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | THE FOLLOWING COMMENTS ARE FROM THE PREVIOUS REVIEW | | DATED 8/13/08 AND HAVE NOT BEEN PROPERLY RESPONDED TO. | | | | 1} THE MINIMUM CURRENT CODES ARE NOT INDICATED ON THE | | ELECTRICAL SHEETS. | | | | 3} THE LIGHTING CONTROL PANEL OR AUTOMATED LIGHTING | | CONTROLS COULD NOT BE LOCATED ON THE PLANS. | | | | 4} NO LIGHTING PERFORMANCE CALCULATIONS WERE GIVEN, | | ONLY FIXTURE WATTAGE PER TYPE.***ALL THAT IS REQUIRED | | FOR THE ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE | | REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE | | CALCULATION PROCEDURES, GENERAL. | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | METHOD DESCRIBED IN SECTION 415.2.B.1. THE INSTALLED | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | DENSITY REQUIREMENTS. INDICATE WATTAGES ON THE FIXTURE | | SCHEDULE TO CORRELATE WITH THE ONES IN THE | | CALCULATIONS. | | | | 6} THE RISER ON E2.1A STILL HAS AN EQUIPMENT GROUNDING | | CONDUCTOR RUNNING FROM THE TAP FEEDER TO THE NEW 200 | | AMP PANEL***250.6.THIS GROUND WOULD BE REQUIRED AFTER | | THE FIRST MEANS OF DISCONNECT PER 250.122. SEE COMMENT | | #1 BELOW. | | | | NEW COMMENTS THIS REVIEW 10/7/08. | | | | 1} DUE TO THE METER LOCATION, A DISCONNECT IS REQUIRED | | PER 230.70. INDICATE LOCATION ON PLAN PER 230.72(A)(1). | | THE AHJ HAS DETERMINED THAT "NEAREST POINT OF ENTRANCE" | | SHALL BE NO FARTHER THAN 8' OF UNPROTECTED CONDUCTORS. | | INDICATE COMPLIANCE WITH THIS ARTICLE ON THE PLAN. | | | | 2} LABEL NEW PANEL LP-4 ON THE RISER DIAGRAM, SHEET | | E2.1A. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-08-13 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-08-13 |
Time |
11:44 |
Sent To |
|
|
Notes |
2008-08-13 11:46:08 | | | ** DENIED PLANS.** | | | | | | 1) NOTE: PLEASE BE SURE THE ELECTRICAL PLANS CONTAIN | | THE FOLLOWING MINIMUM CODES. | | FBC 2004 W/ 2007 REVISIONS. | | 2005 NFPA-70 | | 2003 NFPA-101 | | 2002 NFPA-72 | | | | 2) NOTE: PLEASE INCLUDE MINIMUM LEVELS FOR ANY NEW | | HORN/STROBE DEVICES PER FBC 11-4.28.1,.2 AND .3 (4) FOR | | ADA. | | | | 3) NOTE: PLEASE SEE FBC 13-415.1.ABC.1.1, .1.2 AND .1.3 | | FOR AUTOMATED LIGHTING CONTROLS REQUIRED. STATING ON | | PLANS MOTION SENSOR OR STANDARD SWITCH DOES NOT MEET | | THE MINIMUM PER CODE. | | | | 4) NOTE: PLEASE INDICATE THE LIGHTING PERFORMANCE | | CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1, .1.2. | | | | 5) NOTE: PLANS SEEM TO BE SIGNED WITH SOME SORT OF | | INITIAL. IF THIS IS INDEED THE LEGAL SIGNATURE OF THE | | DESIGN PROFESSIONAL PLEASE SUBMIT A SIGNED, DATED AND | | SEALED LETTER FOR SIGNATURE VERIFICATION. THIS LETTER | | NEEDS TO BE ORIGINAL AND NOTARIZED PER FS 117.05. | | FS 471.025 | | | | 6) NOTE: RISER SHOWS EQUIPMENT GROUNDING CONDUCTOR | | BEFORE THE FIRST MEANS OF DISCONNECT WHICH IS NOT | | PERMITTED. | | 250.6,250.24. THIS CREATES OBJECTIONABLE CURRENTS. | | | | 7) NOTE: PLEASE SEE NEW MECHANICAL COMMENTS AS THE | | COOLING LOAD CALCULATIONS WHICH ARE RAISED SEALS OVER A | | PHOTO-COPIED SIGNATURE WHICH IS IN VIOLATION OF FS | | 471.025, FAC 61G15-23.002 | | | | | | | | | | | | **IMPORTANT** | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | ANY DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-10-21 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-10-21 |
Time |
11:31 |
Sent To |
|
|
Notes |
2008-10-21 11:35:25 | *****APPROVED***** | | | | | | PLAN SHEET E1.1A WAS STAMPED, INITIALED, AND DATED; | | SHEETS A1.1B, E1.6B, & FP1.1 WERE PREVIOUSLY | | FIRE-STAMPED ON 10/10/2008. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-10-10 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-10 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-10 |
Time |
11:32 |
Sent To |
|
|
Notes |
2008-10-10 11:33:24 | STAMPED SHEETS A1.1B, E1.6B AND FP1.1. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-08-12 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-08-12 |
Time |
10:11 |
Sent To |
|
|
Notes |
2008-08-12 10:59:33 | *****DENIED***** | | | | | | 1.STRUCTURES UNDERGOIG CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | COMMENT TO GENERAL DEMOLITION NOTES (SHEET A0.2) | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.AMEND | | GENERAL DEMOLITION NOTE #4 (SHEET A0.2) | | | | 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | 4.INDICATE/SHOW HOW THE SCOPE OF WORK WILL HAVE CAUSE | | FOR ANY FIRE ALARM DEVICES TO BE RELOCATED. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-10-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-16 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-16 |
Time |
11:00 |
Sent To |
|
|
Notes |
2008-10-16 11:01:02 | TO "BOB"#8 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-23 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-23 |
Time |
11:10 |
Sent To |
|
|
Notes |
2008-09-23 11:10:34 | TO "BOB"#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-15 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-29 |
Time |
14:07 |
Sent To |
|
|
Notes |
2008-08-01 08:45:56 | 8/1/08-TO "BOB"#5,PER "RBROWN".PLEASE SEE FRONT | | SCREEN NOTES. | 2008-07-29 14:07:33 | TO "COMM" BD#7 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-25 |
Time |
08:18 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-09-25 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-08-13 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-01 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-13 |
Time |
13:38 |
Sent To |
|
|
Notes |
2008-08-13 13:47:47 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) THE SIGNATURE ON THE COOLING LOAD SUMMARY IS A PHOTO | | COPY, A PHOTO COPY IS NOT ACCEPTABLE IT MUST BE HAND | | WRITTEN. PLEASE CORRECT PER 2004 FBC 13-407.1.ABC.1 | | EXCEPT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-10-16 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-10-16 |
Time |
16:23 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-10-16 |
Time |
16:23 |
Sent To |
|
|
Notes |
2008-10-16 16:24:32 | ****************PROVISO***************** | | FOR INFORMATION ONLY, REVISION NOT REQUIRED. | | PER ARTICLE III SEWERS AND SEWER DISPOSAL. SECTION | | 90-125. PROHIBITIONS AND LIMITATION OF DISCHARGE. | | (20)(D) LOCAL PRETREATMENT STANDARD, TABLE INSET, FOR | | PH (STANDARD UNITS) 5.5--9.5 (MG/L) AND SILVER 4.5 | | (MG/L) MAXIMUM ALLOWABLE CONCENTRATION DURING A 24-HOUR | | PERIOD. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-09-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-09-29 |
Time |
13:09 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-09-29 |
Time |
13:09 |
Sent To |
|
|
Notes |
2008-09-29 13:33:49 | PLUMBING PLAN REVIEW: | | DENIED **2ND TIME: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW | | COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW | | COMMENTS. | | | | 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #8 EW-1: | | THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1 | | DOES NOT COMPLY WITH THE FBC-2004 PLUMBING . PLEASE | | KNOW THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE | | INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED | | LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004 | | PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING | | VALVES. | | | | **RESPONSE NOTED, HOWEVER THE COMMENT HAS NOT BEEN | | ADDRESSED. RESPONSE STATES THAT THE MIXING VALVES TO | | THE HAND SINKS HAVE BEEN REMOVED, HOWEVER THE ORIGINAL | | COMMENT WAS ABOUT THE MIXING VALVE FOR THE EYE WASH NOT | | THE HAND SINKS. PLEASE REVISE PLANS FOR THE EYE WASH | | MIXING VALVE TO READ STANDARD ASSE 1017. PER FBC-2004 | | PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING | | VALVES. | | | | **THE FOLLOWING IS A NEW COMMENT** | | | | 2. SHEET P1.1B WATER HEATER INSTALLATION DETAIL #1: THE | | EXPANSION TANK NEEDS TO BE DOWNSTREAM OF THE WATTS 200 | | SERIES PRESSURE REGULATOR VALVE. PER FBC-2004 PLUMBING | | SECTION 607.3.1 PRESSURE-REDUCING VALVE. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-12 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-12 |
Time |
09:25 |
Sent To |
|
|
Notes |
2008-08-12 09:33:18 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #8 EW-1: | | THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1 | | DOES NOT COMPLY WITH THE FBC-2004 PLUMBING . PLEASE | | KNOW THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE | | INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED | | LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004 | | PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING | | VALVES. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2008-08-04 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2008-08-01 |
Time |
10:35 |
Sent To |
|
|
Notes |
2008-08-04 14:15:27 | PERMIT FOR INTERIOR WORK ONLY.NO SITE OR EXTERIOR | | WORK TO BE DONE AS PART OF THIS PERMIT. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. | | |
|
|