Plan Review Details - Permit 08070714
Plan Review Stops For Permit 08070714
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-17 Cont ID  
Sent By mjacobs Date 2008-10-17 Time 13:43 Rev Time 0.00
Received By mjacobs Date 2008-10-17 Time 13:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-10-03 Cont ID  
Sent By mjacobs Date 2008-10-03 Time 09:51 Rev Time 0.00
Received By mjacobs Date 2008-09-25 Time 07:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-14 Cont ID  
Sent By mjacobs Date 2008-08-14 Time 15:46 Rev Time 0.00
Received By mjacobs Date 2008-08-14 Time 13:40 Sent To PC
Notes
2008-08-14 15:41:45BUILDING PLAN REVIEW
 PERMIT: 08070714
 ADD: 2050 45TH STREET
 CONT: DAVCAO RETAIL SERVICES
 TEL: (214)706-4029
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 8-14-08
 REVIEW 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS. SHOW THIS
 INFORMATION ON THE PLANS.
  
 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE.
  
 5) SHEET A4.1A THE NEW RELOCATED DROP-OFF WINDOW IS
 COUNTER THAT MAY NOT HAVE A CASH REGISTER BUT AT WHICH
 GOODS OR SERVICES ARE SOLD OR DISTRIBUTED THEREFORE, IT
 SHALL HAVE A MINIMUM WIDTH OF 36 INCHES AND A MAXIMUM
 HEIGHT OF 36 INCHES FBC 11-7(2) (I). THE DETAIL DRAWING
 SHOWS THE HEIGHT AT 3'- 3".
  
 6) PLEASE GIVE MORE DETAIL AS TO THE TYPE OF EXAM WHICH
 WILL BE PERFORMED. ADDITIONAL INFORMATION IS REQUIRED
 106.1.2*
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-10-23 Cont ID  
Sent By btrobaug Date 2008-10-23 Time 14:40 Rev Time 0.00
Received By btrobaug Date 2008-10-23 Time 14:25 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-10-02 Cont ID  
Sent By btrobaug Date 2008-10-02 Time 16:44 Rev Time 0.00
Received By btrobaug Date 2008-10-02 Time 16:10 Sent To  
Notes
2008-10-02 16:37:50 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 REPEAT COMMENT:
  
 2} INDICATE COMPLIANCE WITH THE POWER DENSITY
 REQUIREMENTS OF CHAPTER 13 FBC. THE INTERIOR LIGHTING
 POWER ALLOWANCE FOR A BUILDING OR A SEPARATELY METERED
 OR PERMITTED PORTION OF A BUILDING SHALL BE DETERMINED
 BY EITHER THE BUILDING AREA METHOD DESCRIBED IN SECTION
 415.2.C.1 OR THE SPACE-BY-SPACE METHOD DESCRIBED IN
 SECTION 415.2.B.1. TRADE-OFFS OF INTERIOR LIGHTING
 POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING FOR
 WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN USED
 ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING
 POWER IDENTIFIED IN ACCORDANCE WITH SECTION
 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR LIGHTING
 POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH SECTION
 415.2.C.1 OR 415.2.B.1. THIS CAN BE DEMONSTRATED ON THE
 PLANS INDICATED THE WATTAGES OF THE LUMINAIRES CHOSEN
 FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS.***
 NO CALCULATIONS GIVEN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-08-07 Cont ID  
Sent By btrobaug Date 2008-08-07 Time 09:33 Rev Time 0.00
Received By btrobaug Date 2008-08-06 Time 16:03 Sent To  
Notes
2008-08-06 16:53:16 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} MDP-1 IS LISTED AS MLO AND MDP-II IS LISTED AS MCB,
 SHEET E2.1A, THE RISER SHOWS MDP-1 AS HAVING THE 1200
 AMP MAIN BREAKER. SHEET E1.2A NOTE #1 INDICATES THE
 MAIN DISCONNECT OUTSIDE AT THE METER LOCATION, PLEASE
 CORRELATE.
  
 2} INDICATE COMPLIANCE WITH THE POWER DENSITY
 REQUIREMENTS OF CHAPTER 13 FBC. THE INTERIOR LIGHTING
 POWER ALLOWANCE FOR A BUILDING OR A SEPARATELY METERED
 OR PERMITTED PORTION OF A BUILDING SHALL BE DETERMINED
 BY EITHER THE BUILDING AREA METHOD DESCRIBED IN SECTION
 415.2.C.1 OR THE SPACE-BY-SPACE METHOD DESCRIBED IN
 SECTION 415.2.B.1. TRADE-OFFS OF INTERIOR LIGHTING
 POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING FOR
 WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN USED
 ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING
 POWER IDENTIFIED IN ACCORDANCE WITH SECTION
 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR LIGHTING
 POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH SECTION
 415.2.C.1 OR 415.2.B.1. THIS CAN BE DEMONSTRATED ON THE
 PLANS INDICATED THE WATTAGES OF THE LUMINAIRES CHOSEN
 FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-10-21 Cont ID  
Sent By mawillia Date 2008-10-21 Time 11:24 Rev Time 0.00
Received By mawillia Date 2008-10-21 Time 11:08 Sent To  
Notes
2008-10-21 11:22:26*****APPROVED*****
  
 PLAN SHEET E1.1A WAS STAMPED, INITIALED, AND DATED;
 SHEETS A1.1A, E1.6B, & FP1.1A WERE PREVIOUSLY
 FIRE-STAMPED ON 10/03/2008.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-10-03 Cont ID  
Sent By mwennerg Date 2008-10-03 Time 10:30 Rev Time 0.00
Received By mwennerg Date 2008-10-03 Time 10:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-08-12 Cont ID  
Sent By mawillia Date 2008-08-12 Time 12:47 Rev Time 0.00
Received By mawillia Date 2008-08-12 Time 12:37 Sent To  
Notes
2008-08-12 12:39:23*****DENIED*****
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD
 COMMENT TO GENERAL DEMOLITION NOTES (SHEET A0.2)
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.AMEND
 GENERAL DEMOLITION NOTE #4 (SHEET A0.2)
  
 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 4.INDICATE/SHOW HOW THE SCOPE OF WORK WILL HAVE CAUSE
 FOR ANY FIRE ALARM DEVICES TO BE RELOCATED.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH COMMENT WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-23 Cont ID  
Sent By adarroug Date 2008-10-16 Time 10:24 Rev Time 0.00
Received By btrobaug Date 2008-10-16 Time 10:24 Sent To  
Notes
2008-10-16 11:03:39TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-23 Cont ID  
Sent By adarroug Date 2008-09-23 Time 11:22 Rev Time 0.00
Received By adarroug Date 2008-09-23 Time 11:22 Sent To  
Notes
2008-09-23 11:24:24TO "BOB"#15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-08-14 Time   Rev Time 0.00
Received By adarroug Date 2008-07-28 Time 12:33 Sent To  
Notes
2008-08-01 08:45:308/1/08-TO "BOB"#9 PER "RBROWN".PLEASE SEE FRONT
 SCREEN NOTES.
2008-07-28 12:36:58TO "COMM" BD#13

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-08-01 Cont ID  
Sent By tgordon Date 2008-08-01 Time 13:59 Rev Time 0.30
Received By tgordon Date 2008-08-01 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-10-16 Cont ID  
Sent By mperson Date 2008-10-16 Time 15:39 Rev Time 1.00
Received By mperson Date 2008-10-16 Time 15:39 Sent To  
Notes
2008-10-16 15:49:26****************PROVISO*****************
 FOR INFORMATION ONLY, REVISION NOT REQUIRED.
 PER ARTICLE III SEWERS AND SEWER DISPOSAL. SECTION
 90-125. PROHIBITIONS AND LIMITATION OF DISCHARGE.
 (20)(D) LOCAL PRETREATMENT STANDARD, TABLE INSET, FOR
 PH (STANDARD UNITS) 5.5--9.5 (MG/L) AND SILVER 4.5
 (MG/L) MAXIMUM ALLOWABLE CONCENTRATION DURING A 24-HOUR
 PERIOD.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-09-29 Cont ID  
Sent By mperson Date 2008-09-29 Time 10:03 Rev Time 0.45
Received By mperson Date 2008-09-29 Time 10:03 Sent To  
Notes
2008-09-29 11:32:48PLUMBING PLAN REVIEW:
 DENIED **2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 **THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND
 WITH THE PREVIOUS REVIEW COMMENTS AS WELL AS THE
 DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #9 NEW EW:
 THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1
 DOES NOT COMPLY WITH THE FBC-2004 PLUMBING. PLEASE KNOW
 THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE
 INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED
 LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004
 PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING
 VALVES.
  
 **RESPONSE NOTED, HOWEVER THE MIXING VALVE IN QUESTION
 IS FOR THE EYEWASH. THE REFERENCE STANDARD ANSI Z358.1
 FOR THE EYEWASH MIXING VALVE DOES NOT COMPLY WITH THE
 FBC-2004 PLUMBING. THE CORRECT STANDARD IS ASSE 1017.
 PER FBC-2004 PLUMBING SECTION 613.1,
 TEMPERATURE-ACTUATED MIXING VALVES.
  
 2. SHEET P1.1B WATER HEATER DETAIL #1:A MEANS OF
 CONTROLLING INCREASED PRESSURE CAUSED BY THERMAL
 EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN
 ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 .
  
 607.3.1 PRESSURE-REDUCING VALVE.
 FOR WATER SERVICE SYSTEM SIZES UP TO AND INCLUDING 2
 INCHES (51 MM), A DEVICE FOR CONTROLLING PRESSURE SHALL
 BE INSTALLED WHERE, BECAUSE OF THERMAL EXPANSION, THE
 PRESSURE ON THE DOWNSTREAM SIDE OF A PRESSURE-REDUCING
 VALVE EXCEEDS THE PRESSURE-REDUCING VALVE SETTING.
  
 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE.
 WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR
 OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM
 UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT
 THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A
 DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED.
  
 **RESPONE NOTED, HOWEVER THE RESUBMITTED DETAIL IS
 INDICATING THE EXPANSION TANK IN THE WRONG PLACE. THE
 EXPANSION TANK SHOULD BE LOCATED DOWNSTREAM OF THE
 WATTS 200 SERIES PRESSURE REGULATOR VALVE. THE
 RESUBMITTED DETAIL IS INDICATING THE EXPANSION TANK
 UPSTREAM OF THE PRESSURE REGULATOR VALVE. PLEASE
 CORRECT THIS PER FBC-2004 PLUMBING SECTION 607.3.1.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-08-11 Cont ID  
Sent By mperson Date 2008-08-11 Time 08:21 Rev Time 0.00
Received By mperson Date 2008-08-11 Time 08:21 Sent To  
Notes
2008-08-11 09:03:01PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #9 NEW EW:
 THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1
 DOES NOT COMPLY WITH THE FBC-2004 PLUMBING. PLEASE KNOW
 THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE
 INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED
 LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004
 PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING
 VALVES.
  
 2. SHEET P1.1B WATER HEATER DETAIL #1:A MEANS OF
 CONTROLLING INCREASED PRESSURE CAUSED BY THERMAL
 EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN
 ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 .
  
 607.3.1 PRESSURE-REDUCING VALVE.
 FOR WATER SERVICE SYSTEM SIZES UP TO AND INCLUDING 2
 INCHES (51 MM), A DEVICE FOR CONTROLLING PRESSURE SHALL
 BE INSTALLED WHERE, BECAUSE OF THERMAL EXPANSION, THE
 PRESSURE ON THE DOWNSTREAM SIDE OF A PRESSURE-REDUCING
 VALVE EXCEEDS THE PRESSURE-REDUCING VALVE SETTING.
  
 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE.
 WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR
 OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM
 UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT
 THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A
 DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2008-07-29 Cont ID  
Sent By kdfreema Date 2008-07-29 Time 17:00 Rev Time 0.00
Received By kdfreema Date 2008-07-29 Time 17:00 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved