Plan Review Stops For Permit 08070714 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-17 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-10-17 |
Time |
13:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-10-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-10-03 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-09-25 |
Time |
07:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-08-14 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-08-14 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-08-14 |
Time |
13:40 |
Sent To |
PC |
|
Notes |
2008-08-14 15:41:45 | BUILDING PLAN REVIEW | | PERMIT: 08070714 | | ADD: 2050 45TH STREET | | CONT: DAVCAO RETAIL SERVICES | | TEL: (214)706-4029 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 8-14-08 | | REVIEW 1ST | | ACTION: DENIED | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. SHOW THIS | | INFORMATION ON THE PLANS. | | | | 4) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | THIS CODE. | | | | 5) SHEET A4.1A THE NEW RELOCATED DROP-OFF WINDOW IS | | COUNTER THAT MAY NOT HAVE A CASH REGISTER BUT AT WHICH | | GOODS OR SERVICES ARE SOLD OR DISTRIBUTED THEREFORE, IT | | SHALL HAVE A MINIMUM WIDTH OF 36 INCHES AND A MAXIMUM | | HEIGHT OF 36 INCHES FBC 11-7(2) (I). THE DETAIL DRAWING | | SHOWS THE HEIGHT AT 3'- 3". | | | | 6) PLEASE GIVE MORE DETAIL AS TO THE TYPE OF EXAM WHICH | | WILL BE PERFORMED. ADDITIONAL INFORMATION IS REQUIRED | | 106.1.2* | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-10-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-23 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-23 |
Time |
14:25 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-10-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-10-02 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-02 |
Time |
16:10 |
Sent To |
|
|
Notes |
2008-10-02 16:37:50 | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | REPEAT COMMENT: | | | | 2} INDICATE COMPLIANCE WITH THE POWER DENSITY | | REQUIREMENTS OF CHAPTER 13 FBC. THE INTERIOR LIGHTING | | POWER ALLOWANCE FOR A BUILDING OR A SEPARATELY METERED | | OR PERMITTED PORTION OF A BUILDING SHALL BE DETERMINED | | BY EITHER THE BUILDING AREA METHOD DESCRIBED IN SECTION | | 415.2.C.1 OR THE SPACE-BY-SPACE METHOD DESCRIBED IN | | SECTION 415.2.B.1. TRADE-OFFS OF INTERIOR LIGHTING | | POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING FOR | | WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN USED | | ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH SECTION | | 415.2.C.1 OR 415.2.B.1. THIS CAN BE DEMONSTRATED ON THE | | PLANS INDICATED THE WATTAGES OF THE LUMINAIRES CHOSEN | | FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS.*** | | NO CALCULATIONS GIVEN. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-08-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-07 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-06 |
Time |
16:03 |
Sent To |
|
|
Notes |
2008-08-06 16:53:16 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} MDP-1 IS LISTED AS MLO AND MDP-II IS LISTED AS MCB, | | SHEET E2.1A, THE RISER SHOWS MDP-1 AS HAVING THE 1200 | | AMP MAIN BREAKER. SHEET E1.2A NOTE #1 INDICATES THE | | MAIN DISCONNECT OUTSIDE AT THE METER LOCATION, PLEASE | | CORRELATE. | | | | 2} INDICATE COMPLIANCE WITH THE POWER DENSITY | | REQUIREMENTS OF CHAPTER 13 FBC. THE INTERIOR LIGHTING | | POWER ALLOWANCE FOR A BUILDING OR A SEPARATELY METERED | | OR PERMITTED PORTION OF A BUILDING SHALL BE DETERMINED | | BY EITHER THE BUILDING AREA METHOD DESCRIBED IN SECTION | | 415.2.C.1 OR THE SPACE-BY-SPACE METHOD DESCRIBED IN | | SECTION 415.2.B.1. TRADE-OFFS OF INTERIOR LIGHTING | | POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING FOR | | WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN USED | | ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH SECTION | | 415.2.C.1 OR 415.2.B.1. THIS CAN BE DEMONSTRATED ON THE | | PLANS INDICATED THE WATTAGES OF THE LUMINAIRES CHOSEN | | FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-10-21 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-10-21 |
Time |
11:08 |
Sent To |
|
|
Notes |
2008-10-21 11:22:26 | *****APPROVED***** | | | | PLAN SHEET E1.1A WAS STAMPED, INITIALED, AND DATED; | | SHEETS A1.1A, E1.6B, & FP1.1A WERE PREVIOUSLY | | FIRE-STAMPED ON 10/03/2008. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-10-03 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-10-03 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-10-03 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-08-12 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-08-12 |
Time |
12:37 |
Sent To |
|
|
Notes |
2008-08-12 12:39:23 | *****DENIED***** | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | COMMENT TO GENERAL DEMOLITION NOTES (SHEET A0.2) | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.AMEND | | GENERAL DEMOLITION NOTE #4 (SHEET A0.2) | | | | 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | 4.INDICATE/SHOW HOW THE SCOPE OF WORK WILL HAVE CAUSE | | FOR ANY FIRE ALARM DEVICES TO BE RELOCATED. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | EACH COMMENT WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-10-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-16 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-10-16 |
Time |
10:24 |
Sent To |
|
|
Notes |
2008-10-16 11:03:39 | TO "BOB"#7 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-09-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-23 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-23 |
Time |
11:22 |
Sent To |
|
|
Notes |
2008-09-23 11:24:24 | TO "BOB"#15 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-08-14 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-28 |
Time |
12:33 |
Sent To |
|
|
Notes |
2008-08-01 08:45:30 | 8/1/08-TO "BOB"#9 PER "RBROWN".PLEASE SEE FRONT | | SCREEN NOTES. | 2008-07-28 12:36:58 | TO "COMM" BD#13 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-08-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-01 |
Time |
13:59 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-08-01 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-10-16 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-10-16 |
Time |
15:39 |
Rev Time |
1.00 |
Received By |
mperson |
Date |
2008-10-16 |
Time |
15:39 |
Sent To |
|
|
Notes |
2008-10-16 15:49:26 | ****************PROVISO***************** | | FOR INFORMATION ONLY, REVISION NOT REQUIRED. | | PER ARTICLE III SEWERS AND SEWER DISPOSAL. SECTION | | 90-125. PROHIBITIONS AND LIMITATION OF DISCHARGE. | | (20)(D) LOCAL PRETREATMENT STANDARD, TABLE INSET, FOR | | PH (STANDARD UNITS) 5.5--9.5 (MG/L) AND SILVER 4.5 | | (MG/L) MAXIMUM ALLOWABLE CONCENTRATION DURING A 24-HOUR | | PERIOD. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-09-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-09-29 |
Time |
10:03 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2008-09-29 |
Time |
10:03 |
Sent To |
|
|
Notes |
2008-09-29 11:32:48 | PLUMBING PLAN REVIEW: | | DENIED **2ND TIME: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | **THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND | | WITH THE PREVIOUS REVIEW COMMENTS AS WELL AS THE | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #9 NEW EW: | | THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1 | | DOES NOT COMPLY WITH THE FBC-2004 PLUMBING. PLEASE KNOW | | THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE | | INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED | | LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004 | | PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING | | VALVES. | | | | **RESPONSE NOTED, HOWEVER THE MIXING VALVE IN QUESTION | | IS FOR THE EYEWASH. THE REFERENCE STANDARD ANSI Z358.1 | | FOR THE EYEWASH MIXING VALVE DOES NOT COMPLY WITH THE | | FBC-2004 PLUMBING. THE CORRECT STANDARD IS ASSE 1017. | | PER FBC-2004 PLUMBING SECTION 613.1, | | TEMPERATURE-ACTUATED MIXING VALVES. | | | | 2. SHEET P1.1B WATER HEATER DETAIL #1:A MEANS OF | | CONTROLLING INCREASED PRESSURE CAUSED BY THERMAL | | EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 . | | | | 607.3.1 PRESSURE-REDUCING VALVE. | | FOR WATER SERVICE SYSTEM SIZES UP TO AND INCLUDING 2 | | INCHES (51 MM), A DEVICE FOR CONTROLLING PRESSURE SHALL | | BE INSTALLED WHERE, BECAUSE OF THERMAL EXPANSION, THE | | PRESSURE ON THE DOWNSTREAM SIDE OF A PRESSURE-REDUCING | | VALVE EXCEEDS THE PRESSURE-REDUCING VALVE SETTING. | | | | 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE. | | WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR | | OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM | | UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT | | THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A | | DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED. | | | | **RESPONE NOTED, HOWEVER THE RESUBMITTED DETAIL IS | | INDICATING THE EXPANSION TANK IN THE WRONG PLACE. THE | | EXPANSION TANK SHOULD BE LOCATED DOWNSTREAM OF THE | | WATTS 200 SERIES PRESSURE REGULATOR VALVE. THE | | RESUBMITTED DETAIL IS INDICATING THE EXPANSION TANK | | UPSTREAM OF THE PRESSURE REGULATOR VALVE. PLEASE | | CORRECT THIS PER FBC-2004 PLUMBING SECTION 607.3.1. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-11 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-11 |
Time |
08:21 |
Sent To |
|
|
Notes |
2008-08-11 09:03:01 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET P1.1A PLAN KEYED NOTES DESCRIPTION #9 NEW EW: | | THE REFERENCE STANDARD FOR THE MIXING VALVE ANSI Z358.1 | | DOES NOT COMPLY WITH THE FBC-2004 PLUMBING. PLEASE KNOW | | THAT TEMPERATURE-ACTUATED MIXING VALVES, WHICH ARE | | INSTALLED TO REDUCE WATER TEMPERATURE TO DEFINED | | LIMITS, SHALL COMPLY WITH ASSE 1017. PER FBC-2004 | | PLUMBING SECTION 613.1 TEMPERATURE-ACTUATED MIXING | | VALVES. | | | | 2. SHEET P1.1B WATER HEATER DETAIL #1:A MEANS OF | | CONTROLLING INCREASED PRESSURE CAUSED BY THERMAL | | EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN | | ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2 . | | | | 607.3.1 PRESSURE-REDUCING VALVE. | | FOR WATER SERVICE SYSTEM SIZES UP TO AND INCLUDING 2 | | INCHES (51 MM), A DEVICE FOR CONTROLLING PRESSURE SHALL | | BE INSTALLED WHERE, BECAUSE OF THERMAL EXPANSION, THE | | PRESSURE ON THE DOWNSTREAM SIDE OF A PRESSURE-REDUCING | | VALVE EXCEEDS THE PRESSURE-REDUCING VALVE SETTING. | | | | 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE. | | WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR | | OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM | | UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT | | THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A | | DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-07-29 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-07-29 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|