Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-09-15 Cont ID  
Sent By rmcdouga Date 2008-09-15 Time 09:01 Rev Time 0.00
Received By rmcdouga Date 2008-09-15 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-08-13 Cont ID  
Sent By rmcdouga Date 2008-08-13 Time 12:22 Rev Time 0.00
Received By rmcdouga Date 2008-08-13 Time 11:36 Sent To  
Notes
2008-08-13 12:22:042004 FBC W/2007 REVISIONS
 PARKING LOT RENOVATION
  
 DENIED BY BUILDING
  
 1) THE LOCATION OF THE ACCESSIBLE PARKING SPACES ON THE
 PLANS DO NOT COMPLY WITH FBC 11-4.6.2 LOCATION.
 ACCESSIBLE PARKING SPACES SERVING A PARTICULAR BUILDING
 SHALL BE LOCATED ON THE SHORTEST SAFELY ACCESSIBLE
 ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE. IN PARKING FACILITIES THAT DO NOT SERVE A
 PARTICULAR BUILDING, ACCESSIBLE PARKING SHALL BE
 LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL TO
 AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE PARKING
 FACILITY. IN BUILDINGS WITH MULTIPLE ACCESSIBLE
 ENTRANCES WITH ADJACENT PARKING, ACCESSIBLE PARKING
 SPACES SHALL BE DISPERSED AND LOCATED CLOSEST TO THE
 ACCESSIBLE ENTRANCES.
 EACH PARKING SPACE MUST BE NO LESS THAN 12 FEET (3658
 MM) WIDE.
 (1)ALL SPACES MUST BE LOCATED ON AN ACCESSIBLE
 ROUTE NO LESS THAN 44 INCHES (1118 MM)WIDE SO THAT
 USERS WILL NOT BE COMPELLED TO WALK OR WHEEL BEHIND
 PARKED VEHICLES.
  
 2) THE ACCESSIBLE PARKING SPACES ARE REQUIRED TO COMPLY
 WITH FBC 11-4.6.3.
  
 3) ACCESSIBLE PARKING SIGNAGE SHALL COMPLY WITH
 FBC11-4.6.4 SIGNAGE. EACH ACCESSIBLE PARKING SPACE MUST
 BE PROMINENTLY OUTLINED WITH BLUE PAINT, AND MUST BE
 REPAINTED AS NECESSARY, TO BE CLEARLY DISTINGUISHABLE
 AS A PARKING SPACE DESIGNATED FOR PERSONS WHO HAVE
 DISABILITIES AND MUST BE POSTED WITH A PERMANENT
 ABOVE-GRADE SIGN BEARING THE INTERNATIONAL SYMBOL OF
 ACCESSIBILITY, MEETING THE REQUIREMENTS OF COLOR AND
 DESIGN APPROVED BY THE DEPARTMENT OF TRANSPORTATION, OF
 SECTION 11-4.30.7 AND THE CAPTION "PARKING BY DISABLED
 PERMIT ONLY." SUCH SIGN ERECTED AFTER OCTOBER 1, 1996,
 MUST INDICATE THE PENALTY FOR ILLEGAL USE OF THE SPACE.
 SEE ATTACHMENT.
  
 4) CURB RAMPS SHALL COMPLY WITH FBC 11-4.7.1 THRU
 11-4.7.11.
  
 NOTE; ACCESSIBLE PARKING SPACES SHOULD BE RELOCATED TO
 SPACES ADJACENT TO THE BUILDING.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2008-09-15 Cont ID  
Sent By rmcdouga Date 2008-09-15 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2008-09-15 Time 09:04 Sent To  
Notes
2008-09-15 09:39:19NO NEW WORK TO BE DONE IN CITY RIGHT OF WAY. EXISTING
 SIDEWALKS AND DRIVEWAY APRONS TO REMAIN.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-08-07 Cont ID  
Sent By rchokshi Date 2008-08-07 Time 11:40 Rev Time 0.00
Received By rchokshi Date 2008-08-07 Time 11:39 Sent To  
Notes
2008-08-07 11:40:22FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE A DETAIL DRAWING SHOWING ALL THE
 DIMENSIONS FOR DRIVEWAY, APPROACH, SIDEWALK ETC .
  
 2. YOU ARE PUTTING AN APPROACH, DRIVEWAY, SIDEWALK &
 CUTTING A CURB IN CITY'S RIGHT OF WAY. IF YOU DO,YOU
 NEED CITY'S RIGHT OF WAY APPROVAL FROM WINDEL PALMER
 494-1040, 1000 45TH STREET, ENG DEPT.ONCE WE HAVE AN
 APPROVAL FROM WINDEL PALMER, WE WILL REVIEW YOUR
 DRAWINGS.
  
 3. MUST MEET CITY'S STANDARDS FOR APPROACH,
 SIDEWALK,DRIVEWAY ETC. A SHEET " TYPICAL PAVER
 STONE/CONCRETE DRIVEWAY APPROACH DETAILS" ENCLOSED FOR
 YOUR USE.
  
 RASIK CHOKSHI 805-6723

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-10 Cont ID  
Sent By adarroug Date 2008-09-10 Time 11:25 Rev Time 0.00
Received By adarroug Date 2008-09-10 Time 11:25 Sent To  
Notes
2008-09-10 11:25:23TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-04 Cont ID  
Sent By adarroug Date 2008-08-04 Time 08:49 Rev Time 0.00
Received By adarroug Date 2008-08-04 Time 08:49 Sent To ENG
Notes
2008-08-04 08:49:55TO "ENG' BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-08-13 Cont ID  
Sent By rmcdouga Date 2008-08-13 Time 12:23 Rev Time 0.00
Received By rmcdouga Date 2008-07-22 Time 10:53 Sent To  
Notes
2008-07-22 10:54:10TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2008-09-11 Cont ID  
Sent By mcruz Date 2008-09-11 Time 16:17 Rev Time 0.00
Received By mcruz Date 2008-09-11 Time 16:17 Sent To B
Notes
2008-09-11 16:15:30**ZONING PASSED WITH PROVISO:
  
 1. WHEEL STOPS SHALL BE INSTALLED AND SHALL BE LOCATED
 2 FEET FROM CURB.
 2. THE HANDICAP SYMBOL SHALL BE 2 FEET FROM THE
 ENTRANCE OF THE STALL.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-08-03 Cont ID  
Sent By mcruz Date 2008-08-03 Time 12:16 Rev Time 0.00
Received By mcruz Date 2008-08-03 Time 12:10 Sent To I
Notes
2008-08-03 12:15:57***ZONING FAILED***
  
 1.PLEASE PROVIDE RESPONSES IN WRITING.
  
 2.HANDI-CAP PARKING SHALL BE A MINIMUM OF 12 FEET
 WIDE.SEE ATTACHED HANDI-CAP PARKING STALL DETAILS.
  
 3.INDICATE BREAK DOWN OF PARKING, REQUIRED VS
 PROVIDED FOR STANDARD AND HANDICAP PARKING SPACES.
  
 4.PURSUANT TO SECTION 94-485(O)(2)(A) OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS):ALL SPACES
 SHALL HAVE ACCESS TO A CURB RAMP OR CURB CUT, WHEN
 NECESSARY, TO ALLOW ENTRANCE TO THE BUILDING SERVED.
 SPACES SHALL BE LOCATED SO THAT USERS ARE NOT COMPELLED
 TO WALK OR OTHERWISE MOVE BEHIND PARKED VEHICLES,
 EXCLUDING OTHER VEHICLES PARKED IN ADJACENT PARKING
 SPACES FOR THE DISABLED.
  
 5.A SEPARATE PERMIT WILL NEED TO BE ACQUIRED FROM THE
 CITY?S ENGINEERING DEPARTMENT (561.494.1040), FOR THE
 PROPOSED PARKING LOT APRON.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR
 [email protected]
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved