Plan Review Details - Permit 08070486
Plan Review Stops For Permit 08070486 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-28 |
Time |
17:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-28 |
Time |
17:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-07-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-21 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-21 |
Time |
14:46 |
Sent To |
|
|
Notes |
2008-07-21 14:49:27 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.SEE PREVIOUS LIST.THE PRESSURE FOR THE SYSTEM IS | | TOO LOW FOR EXPOSURE C.IF THIS BUILDING IS ADJACENT | | TO THE PARKING LOT, IT APPEARS FROM THE AERIAL THAT IT | | HAS OVER 600 FEET OF OPEN SPACE.SEE FBC1609.6.2.1(2), | | FBC1609.6.2.1(4); -114.81PSF REQUIRED FOR ZONE 3.THE | | SYSTEM SUBMITTED HAS A LIMITATION OF -90PSF. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-17 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-17 |
Time |
14:56 |
Sent To |
|
|
Notes |
2008-07-17 15:00:45 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.MORE INFORMATION IS REQUIRED REGARDING THE | | SURROUNDING TERRAIN TO DETERMINE EXPOSURE B OR C, | | FBC1609.4.THIS MAY BE DONE BY PROVIDING AN AERIAL AND | | MARKING BUILDING 16.IF THIS IS EXPOSURE C, PRESSURES | | FOR THE SYSTEM ARE TOO LOW (-90PSF). | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-17 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-28 |
Time |
17:18 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy