Plan Review Details - Permit 08070373
Plan Review Stops For Permit 08070373 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-09-04 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-09-04 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-08-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-08-20 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-20 |
Time |
11:04 |
Sent To |
|
|
Notes |
2008-08-20 11:13:27 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 1.CBS SUBSTRATE SPECIFIED, BUT ANCHOR SPACING IS FOR | | CONCETE.SEE THE PRODUCT APPROVAL, PAGE 8. | | | | PLEASE CLARIFY, WHY WOULD ANCHOR SPACING BE 10" FOR | | BOTTOM, 18" FOR TOP, SAME CONECTION TYPE AND SUBSTRATE? | | PLEASE SEE PAGE 8 OF PRODUCT APPROVAL, ANCHOR SPACING | | OF 18" NOT COMPLIANT FOR CBS (MASONRY) SUBSTRATE. | | PLEASE REVISE. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-08-11 |
Time |
15:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-11 |
Time |
15:19 |
Sent To |
|
|
Notes |
2008-08-11 15:21:36 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.CBS SUBSTRATE SPECIFIED, BUT ANCHOR SPACING IS FOR | | CONCETE.SEE THE PRODUCT APPROVAL, PAGE 8??? (NUMBERS | | CUT OFF THE BOTTOM). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-22 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-22 |
Time |
15:44 |
Sent To |
|
|
Notes |
2008-07-22 15:44:45 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE | | FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-27 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-27 |
Time |
16:20 |
Sent To |
B |
|
Notes |
2008-08-27 16:20:54 | TO "BUILD" SAMANTHA H. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-15 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-15 |
Time |
16:23 |
Sent To |
B |
|
Notes |
2008-08-15 16:23:57 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-31 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-31 |
Time |
11:59 |
Sent To |
B |
|
Notes |
2008-07-31 11:59:58 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-22 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-14 |
Time |
08:25 |
Sent To |
|
|
Notes |
2008-07-14 08:27:23 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy