Plan Review Stops For Permit 08070031 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-22 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-22 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-05 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-05 |
Time |
08:48 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-07-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-07-08 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-08 |
Time |
12:25 |
Sent To |
M |
|
Notes |
2008-07-08 12:40:58 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | THE FOLLOWING IS REQUIRED TO BE SUBMITTED FOR REVIEW. | | | | 1} SURVEY AND SITE PLANS INDICATING THE PROPOSED | | LOCATION OF THE GENERATOR. GIVE DIMENSIONS FROM | | PROPERTY LINES AND ALL STRUCTURES. INDICATE ANY | | EASEMENTS INVOLVED. THE GENERATOR MAY NOT INTRUDE MORE | | THAN 4 (FOUR) FEET INTO A SETBACK, AND MAY NOT EXHAUST | | CLOSER THAN 5 (FIVE) FEET TO A DIRECT OPENING IN THE | | RESIDENCE. CONTACT THE WPB ZONING DEPARTMENT FOR | | DETAILS REGARDING SETBACKS. | | | | 2} MANUFACTURER SETBACK RECOMMENDATIONS FROM | | STRUCTURES. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-05 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-05 |
Time |
14:38 |
Sent To |
E |
|
Notes |
2008-08-05 14:39:55 | NOTE: SENT TO BILL TROBAUGH PER HIS REQUEST DUE TO | | ZONING ISSUE. *MRPERSON. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-07-09 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-07-09 |
Time |
10:41 |
Sent To |
B |
|
Notes |
2008-07-09 11:15:29 | GAS PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | 1. NOTE: THERE IS A GAS PERMIT NUMBER 07110574, BY | | CONTRACTOR "FLORIDA PUBLIC UTILITIES CO.", THAT HAS | | BEEN APPLIED FOR AND APPROVED ON 4/04/08 THAT WAS | | SUBMITTED WITH GEN/RES PERMIT #08030561, WHICH IS NOW | | VOID. THAT GAS PERMIT APPLICATION AND PLANS NEEDS TO BE | | RESUBMITTED WITH THE NEW GEN/RES PERMIT APPLICATION IN | | ORDER TO RECEIVE THE GENERATOR PERMIT OR VOID THAT | | PERMIT AND APPLY FOR A NEW GAS PERMIT WITH NEW PLANS. | | PER FBC- FUEL GAS CODE SECTION 401.1 SCOPE. | | | | ******IMPORTANT INFORMATION****** | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | MATION AND GAS (OR DIESEL) INFORMATION | | IS ALL SUBMITTED AT THE SAME TIME. THE | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | FORMATION WILL BE ROUTED TOGETHER. THIS | | WILL ENSURE THAT ALL OF THE INFORMATION (PARTICULARLY | | THE MANUFACTURER'S SPECI- | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | 2. MANUFACTURER SETBACK RECOMMENDATIONS FROM | | STRUCTURES. PER FBC-FUEL GAS CODE SECTION 401.1 SCOPE. | | | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2008-07-01 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2008-07-01 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2008-07-01 |
Time |
11:54 |
Sent To |
|
|
Notes |
2008-07-01 11:54:57 | HISTORIC APPROVED BY GJUDGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-28 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-28 |
Time |
15:14 |
Sent To |
Z |
|
Notes |
2008-07-28 15:14:28 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-07-22 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-07-02 |
Time |
10:20 |
Sent To |
|
|
Notes |
2008-07-02 10:20:59 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-07-08 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-08 |
Time |
13:59 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-07-08 |
Time |
13:59 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2008-08-06 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2008-08-06 |
Time |
16:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-08-03 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-08-03 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-08-03 |
Time |
12:38 |
Sent To |
E |
|
Notes |
2008-08-03 12:44:25 | ***ZONING FAILED*** | | | | 1.PURSUANT TO SECTION 94-444(B) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR): MECHANICAL SYSTEMS | | SHALL BE SCREENED FROM VIEW BY LANDSCAPING OR BUILT | | ELEMENTS DESIGNED AS AN INTEGRAL PART OF THE BUILDING | | ARCHITECTURE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR | | [email protected] | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-07-07 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-07-07 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-07-07 |
Time |
13:17 |
Sent To |
E |
|
Notes |
2008-07-07 13:18:00 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES.AS PER | | SECTION 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | SETBACK. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | [email protected] | | | | | | | | | | SENT TO "E" - GENRES BOX |
|
|