Plan Review Details - Permit 08060393
Plan Review Stops For Permit 08060393
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-07-07 Cont ID  
Sent By rmcdouga Date 2008-07-07 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2008-07-07 Time 16:42 Sent To  
Notes
2008-07-07 16:42:202004 FBC W/2007 REVISIONS
 ADDITION AND STORAGE SHED
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE FASTENERS FOR THE ROOF SHEATHING ARE REQUIRED TO
 BE 8D RING SHANK NAILS. SEE R803.2.3.1
  
 4) SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED
 IN THE NOA FOR THE GAF MODIFIED ROOFING SYSTEM WILL BE
 USED. NOTE: THE ASSEMBLIES FOR NON-INSULATED ROOF DECKS
 START ON PAGE 26 OF THE NOA. SPECIFY THE FASTENING
 OPTION AND DESIGN PRESSURE FOR THE ASSEMBLY. SUBMIT RAS
 117 CALCULATIONS FOR ENHANCED FASTENING AT PERIMETER
 AND CORNERS AS REQUIRED BY LIMITATION NUMBER 7 OF THE
 NOA. DCA RULE 9B-72 AND R905.11.3.
  
 5) THE PRODUCT APPROVAL FOR THE PGT SH600 SINGLE HUNG
 WINDOWS HAS BEEN REVISED BY NOA NO. 06-1211.07. THE NOA
 THAT WAS SUBMITTED IS MISSING SHEETS 3, 5 AND 12.
 PLEASE SUBMIT TWO COMPLETE COPIES OF THE NEW NOA. DCA
 RULE 9B-72 AND FBC 106.1* CITY AMENDMENTS.
  
 6) SPECIFY THE MOUNT TYPE, ANCHOR TYPE & SPACING, EDGE
 DISTANCE, ETC. FOR THE STORM PANELS. SEE ATTACHED STORM
 PANEL SCHEDULE. FBC 106.1.1* CITY AMENDMENTS AND
 R301.2.1.2.
  
 SUBMIT TWO COPIES OF THE FOLLOWING INFORMATION FOR THE
 PRE-FAB STORAGE SHED.
  
 7) PROVIDE SURVEY/SITE PLAN SHOWING THE DISTANCE TO
 PROPERTY LINES AND TO OTHER STRUCTURES. R302
  
 8) SUBMIT FOUNDATION PLANS. INDICATE HOW THE SHED WILL
 BE ANCHORED TO THE FOUNDATION. R401
  
 9) SUBMIT PRODUCT APPROVALS, STATE APPROVED
 MANUFACTURED BUILDING PLANS OR SITE SPECIFIC
 ENGINEERING SHOWING THAT THE SHED COMPLIES WITH THE
 2004 FLORIDA BUILDING CODE FOR A 140 MPH WIND SPEED.
 R301
  
 10) THE VALUE OF THE WORK HAS BEEN INCREASED TO
 $13,619.00 BASED ON ICC BUILDING VALUATION DATA. PLEASE
 PAY ADDITIONAL FEES BEFORE RESUBMITTING.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-17 Cont ID  
Sent By btrobaug Date 2008-06-17 Time 10:00 Rev Time 0.00
Received By btrobaug Date 2008-06-17 Time 09:16 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-07-07 Cont ID  
Sent By rmcdouga Date 2008-07-07 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2008-06-16 Time 10:54 Sent To  
Notes
2008-06-16 10:54:39TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-06-17 Cont ID  
Sent By tgordon Date 2008-06-17 Time 13:38 Rev Time 0.25
Received By tgordon Date 2008-06-17 Time 13:38 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-20 Cont ID  
Sent By tgordon Date 2008-06-17 Time 16:51 Rev Time 0.00
Received By mperson Date 2008-06-20 Time 16:27 Sent To B
Notes
2008-06-20 16:36:06PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 SANITARY RISER DIAGRAM: THE ISOMETRIC
 RISER DIAGRAM DOES NOT REFLECT THE FLOOR PLAN. THE
 PROPOSED LAVATORY IS MISSING FROM THE RISER DIAGRAM.
 PER FBC - PLUMBING SECTION 701.1 SCOPE.
  
 2. SHEET A-1 SANITARY RISER DIAGRAM: CLEARLY INDICATE
 THAT A TWO-WAY CLEANOUT WILL BE INSTALLED AT THE
 JUCTION OF THE BUILDING DRAIN AND BUILDING SEWER. PER
 FBC - PLUMBING SECTION 708.3.5.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By choops Date 2008-06-16 Time 13:36 Rev Time 0.00
Received By choops Date 2008-06-16 Time 13:36 Sent To E
Notes
2008-06-16 13:49:22***FAILED***
  
  
 1)SURVEYS SHALL:
  
 * INDICATE SETBACK DIMENSIONS FROM THE PROPOSED
 ADDITION TO ALL ADJACENT PROPERTY LINES.
  
 * INDICATE SEPARATION DISTANCE FROM THE PROPOSED
 ADDITION AND SHED TO THE EXISTING PRINCIPAL STRUCTURE.
  
 * INDICATE LOCATION AND SETBACK DIMENSIONS OF THE
 PROPOSED SHED.
  
 2)THIS PROPERTY LIES WITHIN THE SINGLE FAMILY
 LOW-DENSITY (SF7) RESIDENTIAL ZONING DISTRICT, WHICH
 DOES NOT PROVIDE FOR THE USE OF AN ACCESSORY APARTMENT.
 THIS STRUCTURE SHALL NOT BE USED AS A DWELLING UNIT AND
 SHALL NOT BE GRANTED A RENTAL LICENSE AT ANY POINT.
 REMOVE "BEDROOM" LABELS FROM PLANS AND REPLACE WITH
 ANOTHER LABEL THAT DOES NOT CONNOTE IDEAS OF A DWELLING
 UNIT.
  
 3)PLANS SHALL INDICATE HEIGHT OF PROPOSED STORAGE
 SHED FROM GRADE.
  
 4)INDICATE DISTANCE THE WINDOW A/C UNIT PROJECTS
 FROM THE BUILDING.PURSUANT TO SECTION 94-305 OF THE
 CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS:WINDOW
 A/C UNITS MAY PROJECT NO MORE THAN 18" INTO A REQUIRED
 SETBACK.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK