Plan Review Stops For Permit 08060318 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-08-25 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-08-25 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-08-25 |
Time |
15:00 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-08-18 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-08-18 |
Time |
14:40 |
Sent To |
PC |
|
Notes |
2008-08-18 14:51:46 | | | DENIED | | | | 1)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | DRAWINGS | | | | 2)PLEASE NOTE THAT IF ANY EXTERIOR WORK SUCH AS | | ROOFING, DOORS, WINDOWS ETC. IS PERFORMED PRODUCT | | APPROVALS MUST BE SUBMITTED. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-07-18 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-15 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
kconrad |
Date |
2008-07-18 |
Time |
10:25 |
Sent To |
|
|
Notes |
2008-07-18 10:27:45 | DENIED BY TOM MOORE. PRE-INSPECT COMPLETED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-15 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-15 |
Time |
13:41 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-21 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-21 |
Time |
09:59 |
Sent To |
M |
|
Notes |
2008-08-21 09:59:47 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-08-18 |
Time |
|
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-07 |
Time |
15:39 |
Sent To |
|
|
Notes |
2008-08-07 15:39:14 | TO "SFR" "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-21 |
Time |
11:20 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-08-21 |
Time |
11:20 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-11 |
Time |
16:29 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-08-11 |
Time |
16:29 |
Sent To |
E |
|
Notes |
2008-08-11 16:33:30 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | 1)A/C HEAT PUMP SYSTEM BRYANT MODEL NUMBERS C/U | | 113RNA048 AND A/H FA4ANC048000 LISTED ON THE A/C | | EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE ARI | | DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | CERTIFICATE, SEE 2004 FBC 13-407.1.ABC.3.1.1 OR | | 13-607.1.ABC.3.1.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-21 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-21 |
Time |
14:06 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-15 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-15 |
Time |
15:54 |
Sent To |
B |
|
Notes |
2008-08-15 15:57:42 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET 1.1 SCOPE OF WORK: CLEARLY INDICATE IF THE | | KITCHEN SINK AND DISHWASHER ARE BEING REPLACED OR IF | | THE EXISTING KITCHEN SINK AND DISHWASHER ARE BEING | | REUSED DUE TO THE KITCHEN CABINETS BEING REPLACED | | BECAUSE OF FIRE DAMAGE. PER (W.P.B. AS AMENDED) SECTION | | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS AND | | FBC-2004 PLUMBING SECTION 401.1 SCOPE. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|