Plan Review Details - Permit 08060295
Plan Review Stops For Permit 08060295
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-09-05 Cont ID  
Sent By lmartine Date 2008-09-05 Time 13:59 Rev Time 0.00
Received By lmartine Date 2008-09-05 Time 13:59 Sent To  
Notes
2008-09-05 14:01:11SEE PROVISO'S ON PLAN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-30 Cont ID  
Sent By jgomez Date 2008-06-30 Time 14:51 Rev Time 0.00
Received By jgomez Date 2008-06-30 Time 14:51 Sent To PC
Notes
2008-06-30 15:39:19RESIDENTIAL (R3) POOL, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- POOL DESIGN DOESN'T COMPLY WITHSEC. R4101.18 OF
 2004 FLORIDA RESIDENTIAL CODE.NEED TO PROVIDE A WAY
 OF GETTING OUT OF THE POOL ON BOTH ENDS. REVISE AS
 REQUIRED.
  
 2-NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE. THIS MAYBE PROVIDED AT TIME OF
 PERMIT PICKUP.
  
 3- THIS IS A RESIDENTIAL SWIMMING POOL. CORRECT
 BUILDING CODE TO USE ISCHAPTER 41 OF THE 2004 FLORIDA
 RESIDENTIAL CODE.REVISE ALL NOTES AS REQUIRED TO CITE
 CORRECTCODE SECTION.
  
 4- RESIDENTIAL SWIMMING BARRIER REQUIREMENTS:
 A) PROVIDEMANUFACTURER SPECIFICATIONS FOR BABY
 FENCE TO VERIFY COMPLIANCE WITH SEC. R4101.17.1.15 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 B) EXISTING WOOD FENCE: PROVIDE SPECIFICATIONS FOR
 GATE TO SHOW COMPLIANCE WITH SEC. R4101.17.1.8 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-16 Cont ID  
Sent By btrobaug Date 2008-06-16 Time 08:02 Rev Time 0.00
Received By btrobaug Date 2008-06-16 Time 08:02 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-06-19 Cont ID  
Sent By mperson Date 2008-06-19 Time 15:46 Rev Time 0.00
Received By mperson Date 2008-06-19 Time 15:46 Sent To B
Notes
2008-06-19 15:46:49NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2008-06-10 Cont ID  
Sent By swurafti Date 2008-06-10 Time 16:52 Rev Time 0.00
Received By swurafti Date 2008-06-10 Time 16:52 Sent To  
Notes
2008-06-10 16:53:04HISTORIC APPROVED BY GJUDGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-30 Cont ID  
Sent By jgomez Date 2008-06-30 Time 15:39 Rev Time 0.00
Received By jgomez Date 2008-06-11 Time 08:39 Sent To  
Notes
2008-06-11 08:39:26TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-06-19 Cont ID  
Sent By mperson Date 2008-06-19 Time 15:45 Rev Time 0.00
Received By mperson Date 2008-06-19 Time 15:45 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2008-09-09 Cont ID  
Sent By kdfreema Date 2008-09-09 Time 17:01 Rev Time 0.00
Received By kdfreema Date 2008-09-09 Time 17:01 Sent To  
Notes
2008-09-09 17:01:30SEE ZBA 3229, APPROVED 9/4/08.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-12 Cont ID  
Sent By choops Date 2008-06-12 Time 08:55 Rev Time 0.00
Received By choops Date 2008-06-12 Time 08:55 Sent To E
Notes
2008-06-12 09:00:44***FAILED***
  
  
 1)POOL AS PROPOSED DOES NOT MEET THE MINIMUM SETBACK
 REQUIREMENTS.PURSUANT TO SECTION 94-304(D):MINIMUM
 SETBACK REQUIREMENT FROM WATERS' EDGE TO THE CORNER
 SIDE LOT LINE (ALONG SPRUCE) IS TEN (10) FEET.PLEASE
 REVISE.
  
 2)IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO
 OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN
 AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES.
 POOL/PAVER DECK SHALL BE SETBACK A MINIMUM OF 1' FROM
 ALL PROPERTY LINES TO ALLOW FOR ADEQUATE DRAINAGE.
 PLEASE REVISE.
  
  
 NOTE:EXISTING FENCE ENCLOSURE MUST COMPLY WITH:
  
 THE CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTION, 94-304(D)(2)(B)+(C):
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  