Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-08 Cont ID  
Sent By jgomez Date 2008-08-08 Time 16:47 Rev Time 0.00
Received By jgomez Date 2008-08-08 Time 16:47 Sent To PC
Notes
2008-08-08 16:50:28BUILDING REVIEW APPROVED WITH PROVISO:
 1- AS PER CONVERSATION WITH OWNER (RICK CRUZ) HOUSE
 WILL HAVE FENCE AROUNDHOUSE AND EXIT ALARMS WILL BE
 INSTALLED IN THE HOUSE.ACCESS GATES TO COMPLY WITH
 SEC. R4101.17.1.8 AND EXIT ALARMS TO COMPLY WITH SEC.
 R4101.17.1.9 OF 2004 FLORIDA RESIDENTIAL CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-30 Cont ID  
Sent By jgomez Date 2008-06-30 Time 11:35 Rev Time 0.00
Received By jgomez Date 2008-06-30 Time 11:34 Sent To PC
Notes
2008-06-30 13:34:03RESIDENTIAL (R3)POOL, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- CLEARLY SPECIFY HOW COMPLYING WITH THE RESIDENTIAL
 SWIMMING BARRIER REQUIREMENTS OF SEC. R4101.17 OF 2004
 FLORIDA RESIDENTIAL CODE.NEED TO SPECIFY HOW
 COMPLYING WITH THIS CODE SECTION WHEN HAVING ACCESSS TO
 THE POOL FROM THE HOUSE OR HAVING ACCES TO THE POOL
 FROMTHE OUTSIDE.SHEET 1 OF 3 SHOWS EXISTING FENCE,
 BUT IT DOESN' SHOW LOCATION OF GATES AND IF THEY COMPLY
 WITH SEC. R4101.17.1.8 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 2- DRAWINGS NEED TO SHOW COMPLIANCE WITH SEC. R4101.18
 OF 2004 FLORIDA RESIDENTIAL CODE.LADDERS OR STEPS ARE
 REQUIRED ON BOTH ENDS.NEED TO PROVIDE A WAY OF
 GETTING OUT OF THE POOL ON BOTH ENDS OF POOL.
  
 3- UPDATE ALL NOTES ON SHEET 1 OF 3.. THEY ALL REFER TO
 SEC. 424 OF FBC.THIS IS A RESIDENTIAL SWIMMING POOL
 AND CORRECT CODE TO BE REFERRED TO IS THE 2004 FLORIDA
 RESIDENTIAL CODE CHAPTER 41. SEE CHAPTER AND REVISE ALL
 NOTES AS REQUIRED WITH CORRESPONDING CODE SECTION..
  
 4-POOL VALUE WAS UPDATED TO $23,150 AS REQUIRED BY
 SEC. 108.3 CITY AMENDMENTS TO FBC 2004. OWES $57.77 FOR
 UPDATED VALUATION.
  
 5- CLARIFY IF THERE IS GOING TO BE A POOL DECK OR NOT.
 IF YES, THEN INCLUDE DECK INFORMATION AND VALUATION.
 SEC. 108.3 CITY AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER.
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-08-08 Cont ID  
Sent By btrobaug Date 2008-08-08 Time 09:28 Rev Time 0.00
Received By btrobaug Date 2008-08-08 Time 09:21 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-16 Cont ID  
Sent By btrobaug Date 2008-06-16 Time 07:12 Rev Time 0.00
Received By btrobaug Date 2008-06-16 Time 07:07 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2008-08-08 Cont ID  
Sent By mperson Date 2008-08-08 Time 10:20 Rev Time 0.00
Received By mperson Date 2008-08-08 Time 10:20 Sent To B
Notes
2008-08-08 10:21:55CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL
 GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL
 INSPECTION.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-06-18 Cont ID  
Sent By mperson Date 2008-06-18 Time 15:09 Rev Time 0.00
Received By mperson Date 2008-06-18 Time 15:09 Sent To B
Notes
2008-06-18 15:10:31CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL
 GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL
 INSPECTION.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2008-06-06 Cont ID  
Sent By swurafti Date 2008-06-06 Time 14:44 Rev Time 0.00
Received By swurafti Date 2008-06-06 Time 14:44 Sent To  
Notes
2008-06-06 14:46:36HISTORIC APPROVED BY JPAPA

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-04 Cont ID  
Sent By adarroug Date 2008-08-04 Time 09:46 Rev Time 0.00
Received By adarroug Date 2008-08-04 Time 09:46 Sent To Z
Notes
2008-08-04 09:46:41TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-30 Cont ID  
Sent By jgomez Date 2008-06-30 Time 13:34 Rev Time 0.00
Received By jgomez Date 2008-06-09 Time 10:08 Sent To  
Notes
2008-06-09 10:08:42TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-08-08 Cont ID  
Sent By mperson Date 2008-08-08 Time 10:20 Rev Time 0.00
Received By mperson Date 2008-08-08 Time 10:20 Sent To G
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-06-18 Cont ID  
Sent By mperson Date 2008-06-18 Time 15:09 Rev Time 0.00
Received By mperson Date 2008-06-18 Time 15:09 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2008-08-08 Cont ID  
Sent By mcruz Date 2008-08-08 Time 16:16 Rev Time 0.00
Received By mcruz Date 2008-08-08 Time 16:16 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2008-08-06 Cont ID  
Sent By mcruz Date 2008-08-06 Time 11:12 Rev Time 0.00
Received By mcruz Date 2008-08-06 Time 11:10 Sent To E
Notes
2008-08-06 11:11:59***ZONING FAILED***
  
 1.INDICATE ON PLAN THAT THE FENCE COMPLETELY ENCLOSES
 THE POOL.DOES NOT APPEAR SO ON SURVEY. PLEASE
 CLARIFY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR
 [email protected]
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-10 Cont ID  
Sent By choops Date 2008-06-10 Time 13:22 Rev Time 0.00
Received By choops Date 2008-06-10 Time 13:22 Sent To E
Notes
2008-06-10 13:26:36***FAILED***
  
  
 1)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT
 FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT
 SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO
 THE MINIMUM STANDARDS PROVIDED BELOW.
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS), SECTION,
 94-304(D)(2)(B)+(C):
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
  
 NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT
 TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN
 AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,