Plan Review Stops For Permit 08060051 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-04-29 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2009-04-29 |
Time |
13:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-12-01 |
Time |
14:43 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2008-12-01 |
Time |
14:43 |
Sent To |
FIRE |
|
Notes |
2008-12-01 15:03:17 | BUILDING PLAN REVIEW | | PERMIT: 08060051 | | ADD: 300 N DIXIE HWY | | CONT: KNIGHT ELECTRIC | | TEL: (561)689- 3500 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 1B) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | 2) 2ND REQUEST, FEUL STORAGE TANK IS BEING LOCATED TO | | THE EXTERIOR OF THE BUILDING AS PER M-1,( OPEN PARKING | | GARAGE) PLEASE PROVIDE ATTACHMENT FOR MOMENT OF | | OVERTURNING, UPLIFT AND SLIPPAGE. 1609.3.1. | | VISITED JOBSITE PARKING GAGARE CONSIDERED OPEN! | | | | 3 )2ND REQUEST, PLEASE PROVIDE WIND INFORMATION: | | 1603.1.4 WIND DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | BUILDING: | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | (KM/HR). | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. 3. | | WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | DIRECTION SHALL BE INDICATED. | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | PROFESSIONAL. | | | | 4) 2ND REQUEST, SHEET E-3 GENERATOR DETAIL INDICATES TO | | SEE STRUCTURAL SHEET FOR SLAB DETAILS, ALSO INCLUDE | | ANCHOR DETAILS FOR THE NEW GENERATOR. 1609.3.1 | | ANCHORAGE AGAINST OVERTURNING, UPLIFT AND SLIDDING. | | MISSING ARCHITECURAL AND STRUCTURAL SHEETS. | | | | 5-6) COMPLIED. | | | | 7) NEW COMMENT, VISITED JOBSITE AND THE SOUTH WALL OF | | THE PARKING GARAGE IS OPEN TO TTHE WEATHER, A WING WALL | | APPROXIMATELY 42" TALL. SHEET M-1 NEW GENERATOR AREA | | INDICATES A LOUVER IN THE WALL, IS THERE GOING TO BE A | | NEW WALL INSTALLED BETWEEN COLUMNS? | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-06-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-06-30 |
Time |
15:01 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2008-06-30 |
Time |
15:01 |
Sent To |
|
|
Notes |
2008-06-30 15:31:17 | BUILDING PLAN REVIEW | | PERMIT: 08060051 | | ADD: 300 N DIXIE HWY | | CONT: KNIGHT ELECTRIC | | TEL: (561)689- 3500 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 1B) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | 2) FEUL STORAGE TANK IS BEING LOCATED TO THE EXTERIOR | | OF THE BUILDING AS PER M-1, PLEASE PROVIDE ATTACHMENT | | FOR MOMENT OF OVERTURNING, UPLIFT AND SLIPPAGE. | | 1609.3.1. | | | | 3) PLEASE PROVIDE WIND INFORMATION: 1603.1.4 WIND | | DESIGN DATA. | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | BUILDING: | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | (KM/HR). | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. 3. | | WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | DIRECTION SHALL BE INDICATED. | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | PROFESSIONAL. | | | | 4) SHEET E-3 GENERATOR DETAIL INDICATES TO SEE | | STRUCTURAL SHEET FOR SLAB DETAILS, ALSO INCLUDE ANCHOR | | DETAILS FOR THE NEW GENERATOR. 1609.3.1 ANCHORAGE | | AGAINST OVERTURNING, UPLIFT AND SLIDDING. | | MISSING ARCHITECURAL AND STRUCTURAL SHEETS. | | | | 5) E-SHEETS ENGINEER MELQUIADES GARCIA IS MISSING IN | | THIER TITLEBLOCK: | | 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED | | BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE: | | NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR, | | THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE | | NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER | | IS PRACTICING (471.025 F.S. AND 471.023 F.S.). | | | | 6) P-1 SHEET ENGINEER ROBERTO BETANCOURT ALSO IS | | MISSING INFORMATION IN THEIR TITLE BLOCK: | | 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED | | BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE: | | NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR, | | THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE | | NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER | | OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER | | IS PRACTICING (471.025 F.S. AND 471.023 F.S.). | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-04 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-04 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-07-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-07-02 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-02 |
Time |
10:33 |
Sent To |
|
|
Notes |
2008-07-02 13:04:13 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, NFPA-37, 2004 FBC | | CHAPTER 1 AS AMENDED AND FOUND NONCOMPLIANT WITH THE | | FOLLOWING: | | | | SHEET E-4: | | | | 1} PROVIDE PANEL SCHEDULES FOR "EML" AND "EMP". | | | | 2} CIRCUIT #3 IN PANEL "EDP" INCORRECTLY LISTS PANEL | | "EMP" AS A FEED, IT FEEDS PANEL "EML" ON THE RISER | | DIAGRAM. | | | | 3} TRANSFORMER "PEG" MUST HAVE PRIMARY AND SECONDARY | | OVERCURRENT PROTECTION PER 450.3(B). | | | | 4} INDICATE THE INPUT AND OUTPUT VOLTAGES FOR | | TRANSFORMER "PEG". | | | | 5} INDICATE THE EMERGENCY FEED FOR PANEL "EGP", | | TRANSFORMER "T-2" AND PANEL "EGR". HOW ARE THE GARAGE | | EMERGENCY LIGHTS BEING FED? | | | | 6} VERIFY THAT XFMR "PEG" AT 15KVA WILL FEED THE 28KVA | | LOAD ON "EMP". | | | | 7} PER NFPA-37.4.1.2.3ENGINE ROOMS LOCATED WITHIN | | STRUCTURES SHALL HAVE INTERIOR WALLS, FLOORS, AND | | CEILINGS OF AT LEAST 1-HOUR FIRE RESISTANCE RATING. | | SHEET E-3 INDICATES A METALLIC FENCE ENCLOSING THE | | GENERATOR. | | | | PROVIDE A WRITTEN RESPONSE, REMOVE OLD AND VOIDED | | SHEETS AND PROVIDE ONE COPY OF THE OLD PLANS WHEN | | RESUBMITTING. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-12-08 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-12-08 |
Time |
14:06 |
Sent To |
|
|
Notes |
2008-12-08 14:26:13 | *****APPROVED***** | | | | | | PLAN SHEETS E-1 AND P-1 WERE STAMPED, INITIALED, AND | | DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-07-03 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-07-03 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-07-03 |
Time |
10:04 |
Sent To |
|
|
Notes |
2008-07-03 10:12:17 | ***DENIED*** | | | | 1) TITLE BLOCK SHOWS AN ADDRESS OF 215 OLIVE AVE. AND | | PERMIT APPLICATION INDICATES 300 N. DIXIE HIGHWAY. | | PLEASE CORRELATE AND IF ADDRESS IS ON OLIVE AVE, | | INDICATE NORTH OR SOUTH. | | | | 2) INDICATE ADOPTED EDITIONS UNDER CODES AND STANDARDS. | | IN ADDITION, NFPA 110 STANDARD FOR EMERGENCY AND | | STANDBY POWER SYSTEMS SHALL BE REFERENCED. | | | | 3) PROVIDE MANUFACTURER SPECIFICATION SHEETS FOR | | GENERATOR AND ASSOCIATED EQUIPMENT. | | | | 4) ILLUSTRATE BUILDING OPENINGS IN RELATION TO THE | | EXHAUST TERMINUS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW | | FIRE PREVENTION (561) 804-4756 |
|
|
Review Stop |
FUEL |
DIESEL GENERATOR |
Rev No |
1 |
Status |
P |
Date |
2008-11-22 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-22 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-11-22 |
Time |
16:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-04-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-04-28 |
Time |
16:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-04-28 |
Time |
16:47 |
Sent To |
|
|
Notes |
2009-04-28 16:48:07 | TO JW'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-04-29 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2009-04-20 |
Time |
16:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-11-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-13 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-13 |
Time |
11:19 |
Sent To |
|
|
Notes |
2008-11-13 11:20:04 | TO "BOB"#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-07-03 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-06-04 |
Time |
16:34 |
Sent To |
|
|
Notes |
2008-06-04 16:51:36 | TO "COMM" BD#20 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-11-22 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-22 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2008-11-22 16:49:54 | PROVIDE PRODUCT APPROVAL DOCUMENTATION FOR BUILDING | | PLAN REVIEW WHICH HAS BEEN APPROVED IN WRITING BY THE | | DESIGNER OR RECORD IN ACCORDANCE WITH FBCB 106.3.3. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-06-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-06-26 |
Time |
08:17 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-06-26 |
Time |
08:17 |
Sent To |
|
|
Notes |
2008-06-26 08:20:45 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) PLEASE SHOW COMPLIANCE WITH NFPA 37, 6.3.2.4 FUEL | | TANKS WITHIN STRUCTURES SHALL BE PROVIDED WITH SPILL | | CONTAINMENT CONSISTING OF EITHER A WALL, A CURB, OR A | | DIKE HAVING A CAPACITY AT LEAST EQUAL TO THAT OF THE | | LARGEST SURROUNDED TANK. | | | | 2) PLEASE SHOW ON PLANS OR STATE IF THERE ARE ANY OTHER | | BUILDINGS, BUILDING OPENINGS, PROPERTY LINES, OR | | WALKWAYS WITH IN 10 FEET OF THE GENERATOR EXHAUST | | OUTLET, PER NFPA 37. | | | | 3) PLAN M-1 SHOWS A 72"X48" LOUVER IS TO BE INSTALLED. | | PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR LOUVER, | | SEE FS 553.842(1) AND FAC RULE 9B-72, 9B-72.005, AND | | FAC 9B-72.010(31)(C). | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | *** PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | IN WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND | | SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B. | | AMEND. 106.3. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-04-29 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2009-04-29 |
Time |
13:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
Sent By |
mflis |
Date |
2008-11-24 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
mflis |
Date |
2008-11-24 |
Time |
12:14 |
Sent To |
|
|
Notes |
2008-11-24 12:15:17 | ZONING REVIEW: PASSED WITH PROVISO: | | | | ** PARKING SPACE #22 SHALL BE REMOVED AND STRIPED OFF | | IN WHITE AS THE INSTALLATION OF THE BOLLARDS AND | | EQUIPMENT WILL MAKE IN NON-FUNCTIONAL. | | | | MATT FLIS - 822-1445 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-06-14 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2008-06-14 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2008-06-14 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|