Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-23 Cont ID  
Sent By lmartine Date 2008-10-23 Time 12:31 Rev Time 0.00
Received By lmartine Date 2008-10-23 Time 12:31 Sent To  
Notes
2008-10-23 12:34:26REVISION TO ALTER BEAM HEIGHT AND CHANGE METAL ROOF TO
 ASPHALT SHINGLE ROOF COVER. OK LM

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-13 Cont ID  
Sent By lmartine Date 2008-08-13 Time 14:42 Rev Time 0.00
Received By lmartine Date 2008-08-13 Time 14:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-25 Cont ID  
Sent By amorse Date 2008-06-25 Time 16:00 Rev Time 0.00
Received By amorse Date 2008-06-25 Time 16:00 Sent To PC
Notes
2008-06-25 16:20:49 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $31.66FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD
  
 5)THE 2006 AMENDMENTS TO THE 2004 FBC (1609.4)
 REQUIRE BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN
 THAT IS DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS
 OPEN GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF
 600 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C
 CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND
 PRESSURES ACCORDINGLY. NOTE: THE PRODUCT APPROVAL
 DESIGN PRESSURES SEEM TO WORK EVEN AT THE INCREASED
 VALUES
  
 6)PROVIDE DETAILS OF THE STRUCTURAL BUILDING
 CONNECTION WHERE NEW AND EXISTING FOUNDATIONS, COLUMNS
 AND TIE BEAMS ARE JOINED
  
 7)PROVIDE TOP OF BEAM AND MEAN ROOF HEIGHT
 ELEVATIONS
  
 8)SUBMIT A COPY OF THE RECORDED NOTICE OF
 COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT.
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS WITH
 REVISIONS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY FOR
 REFERENCE.
  
 ADDITIONAL PERMITS WILL BE REQUIRED FORELECTRICAL
 AND ROOFING
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-05 Cont ID  
Sent By btrobaug Date 2008-06-05 Time 15:23 Rev Time 0.00
Received By btrobaug Date 2008-06-05 Time 15:23 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-15 Cont ID  
Sent By adarroug Date 2008-10-15 Time 09:12 Rev Time 0.00
Received By adarroug Date 2008-10-15 Time 09:12 Sent To B
Notes
2008-10-15 09:12:49TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-06-25 Time   Rev Time 0.00
Received By adarroug Date 2008-06-02 Time 12:39 Sent To  
Notes
2008-06-02 12:40:09TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-06-04 Cont ID  
Sent By tgordon Date 2008-06-04 Time 14:14 Rev Time 0.15
Received By tgordon Date 2008-06-04 Time 14:14 Sent To E
Notes
2008-06-04 14:14:49NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 2 Status P Date 2008-07-23 Cont ID  
Sent By mcruz Date 2008-07-23 Time 16:47 Rev Time 0.00
Received By mcruz Date 2008-07-23 Time 16:46 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-03 Cont ID  
Sent By choops Date 2008-06-03 Time 13:16 Rev Time 0.00
Received By choops Date 2008-06-03 Time 13:16 Sent To E
Notes
2008-06-03 13:18:23***FAILED***
  
  
 1)SITE PLAN SHALL INDICATE SETBACK DIMENSIONS TO ALL
 ADJACENT PROPERTY LINES FROM GARAGE ADDITION.
  
 2)INDICATE OVERHANG DIMENSIONS.PURSUANT TO SECTION
 94-305 OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS:STRUCTURAL OVERHANGS SHALL NOT PROJECT
 MORE THAN 3' INTO A REQUIRED SETBACK.
  
 3)ELEVATIONS SHALL INDICATE HEIGHT DIMENSIONS OF
 PROPOSED.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK