Plan Review Stops For Permit 08050685 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-09-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-09-26 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-09-26 |
Time |
17:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-09-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-09-26 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-09-26 |
Time |
13:46 |
Sent To |
|
|
Notes |
2008-09-26 15:14:23 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | 1. SEE PAGE11 OF STORM PANEL PRODUCT APPROVAL. A FACTOR | | OF .86 MUST BE APPLIED TO FASTENER SPACING, BOTTOM. | | YOU'VE CIRCLED 12" BOTTOM 1 WITH 3" EDGE DISTANCE. IT | | APPEARS THAT THE FACTOR WAS APPLIED TO THE TOP BUT NOT | | TO THE BOTTOM. TWO DIFFERENT ANCHORS WERE CIRCLED ON | | THE FACTOR CHART ON PAGE 11, BUT ONLY ONE ANCHOR | | SPECIFIED ON THE INSTALLATION SCHEDULE. | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, THE | | SHUTTER MOUNTING CONNECTION TYPE SHOULD CORRELATE WITH | | THE ANCHOR SCHEDULE; IT APPEARS THAT YOU ARE USING TOP | | 1 AND BOTTOM 1. THE SPECIFIC ANCHOR TYPE SHOULD BE THE | | ANCHOR; NOT CLEAR WHICH ANCHOR YOU ARE USING BECAUSE | | YOU'D WRITTEN "TAPCON" IN ANOTHER PLACE BUT CIRCLED TWO | | DIFFERENT ANCHORS ON THE PRODUCT APPROVAL. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-09-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-09-08 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-09-08 |
Time |
12:48 |
Sent To |
|
|
Notes |
2008-09-08 12:58:00 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | 1. SEE PAGE11 OF STORM PANEL PRODUCT APPROVAL. A FACTOR | | OF .86 MUST BE APPLIED TO FASTENER SPACING, BOTTOM. | | YOU'VE CIRCLED 12" BOTTOM 1 WITH 3" EDGE DISTANCE. IT | | APPEARS THAT THE FACTOR WAS APPLIED TO THE TOP BUT NOT | | TO THE BOTTOM. TWO DIFFERENT ANCHORS WERE CIRCLED ON | | THE FACTOR CHART ON PAGE 11, BUT ONLY ONE ANCHOR | | SPECIFIED ON THE INSTALLATION SCHEDULE. | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, THE | | SHUTTER MOUNTING CONNECTION TYPE SHOULD CORRELATE WITH | | THE ANCHOR SCHEDULE; IT APPEARS THAT YOU ARE USING TOP | | 1 AND BOTTOM 1. THE SPECIFIC ANCHOR TYPE SHOULD BE THE | | ANCHOR; NOT CLEAR WHICH ANCHOR YOU ARE USING BECAUSE | | YOU'D WRITTEN "TAPCON" IN ANOTHER PLACE BUT CIRCLED TWO | | DIFFERENT ANCHORS ON THE PRODUCT APPROVAL. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-08-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-08-25 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-25 |
Time |
13:28 |
Sent To |
|
|
Notes |
2008-08-25 13:30:29 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | 1.COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 2.PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS | | WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH | | THE INSTALLATION SCHEDULE, ITEM 2 ABOVE. | | | | 3.SHOW EMERGENCY MEANS OF ESCAPE ON THE PLAN, FBC | | R301. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-29 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-29 |
Time |
10:24 |
Sent To |
|
|
Notes |
2008-05-29 10:24:23 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED | | ITEMS APPLY*** | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | 301.2.1.2.PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS | | ARE USED, COMPLETE THE ATTACHED INSTALLATION SCHEDULE. | | IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 507.3, | | PROVIDE CALCULATIONS. | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-09-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-19 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-19 |
Time |
09:30 |
Sent To |
B |
|
Notes |
2008-09-19 09:30:30 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-03 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-03 |
Time |
12:19 |
Sent To |
B |
|
Notes |
2008-09-03 12:20:15 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-18 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-18 |
Time |
08:27 |
Sent To |
B |
|
Notes |
2008-08-18 08:27:41 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-29 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-27 |
Time |
14:28 |
Sent To |
|
|
Notes |
2008-05-27 14:29:14 | TO "MISC" BOX#1 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-08-24 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-08-24 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-08-24 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|