Plan Review Details - Permit 08050667
Plan Review Stops For Permit 08050667
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-20 Cont ID  
Sent By lmartine Date 2008-06-20 Time 12:22 Rev Time 0.00
Received By lmartine Date 2008-06-20 Time 12:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-18 Cont ID  
Sent By shill Date 2008-06-18 Time 13:30 Rev Time 0.00
Received By shill Date 2008-06-18 Time 13:30 Sent To  
Notes
2008-06-18 13:34:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE PLAN STATES THAT "ONE OF THE FOLLOWING" WILL BE
 PROVIDED IN REGARDS TO POOL SAFETY, FBC R 4101.17.
 OPTIONS 10.3 AND 10.4 AREN'T COMPLIANT ALONE; THEY BOTH
 ARE TO BE USED IN COMBINATION WITH A BARRIER FENCE.
 PLEASE REVISE.
  
 2.VALUATION ADJUSTMENT HAS BEEN DONE USING MARSHALL &
 SWIFT, FBC*108.3.ADDITIONAL FEES DUE, SEE ATTACHED
 ($74.54).
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-03 Cont ID  
Sent By btrobaug Date 2008-06-03 Time 08:23 Rev Time 0.00
Received By btrobaug Date 2008-06-03 Time 08:19 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-06-06 Cont ID  
Sent By mperson Date 2008-06-06 Time 11:55 Rev Time 0.00
Received By mperson Date 2008-06-06 Time 11:55 Sent To B
Notes
2008-06-06 11:55:59NOTE: THERE IS NO POOL HEATER, GAS OR ELECTRIC.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-18 Cont ID  
Sent By shill Date 2008-06-18 Time 13:34 Rev Time 0.00
Received By shill Date 2008-05-23 Time 14:34 Sent To  
Notes
2008-05-23 14:34:18TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-06-06 Cont ID  
Sent By mperson Date 2008-06-06 Time 11:53 Rev Time 0.00
Received By mperson Date 2008-06-06 Time 11:53 Sent To G
Notes
2008-06-06 11:54:34****************PROVISO****************
 FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC.
 R4101.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE.(ADD TO NOTES)
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-06-19 Cont ID  
Sent By choops Date 2008-06-19 Time 12:04 Rev Time 0.00
Received By choops Date 2008-06-19 Time 12:04 Sent To B
Notes
2008-06-19 12:04:48***APPROVED - RESUB #1***
  
  
  
  
 SENT TO "B" - SH

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-30 Cont ID  
Sent By choops Date 2008-05-30 Time 09:59 Rev Time 0.00
Received By choops Date 2008-05-30 Time 09:59 Sent To E
Notes
2008-05-30 10:02:59***FAILED***
  
  
 1)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT
 FENCE COMPLETELY SURROUNDING THE POOL (EAST SIDE NOT
 ENCLOSED), A FENCE PERMIT SHALL BE SUBMITTED
 CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS
 PROVIDED BELOW.
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS), SECTION,
 94-304(D)(2)(B)+(C):
  
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720