Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-07-03 Cont ID  
Sent By rmcdouga Date 2008-07-03 Time 08:01 Rev Time 0.00
Received By rmcdouga Date 2008-07-03 Time 08:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-17 Cont ID  
Sent By rmcdouga Date 2008-06-17 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2008-06-17 Time 16:53 Sent To  
Notes
2008-06-18 10:42:192004 FBC W/2007 REVISIONS
 REROOF
  
 DENIED BY BUILDING
  
 1) THE ASSEMBLY THAT IS SPECIFIED ON THE NOA (PAGE 30)
 IS FOR USE AS A TILE UNDERLAYMENT. PLEASE SPECIFY THE
 APPROPRIATE ASSEMBLY FOR THE FLAT ROOF. NOTE: PAGE 26
 IS FOR SBS ON A NON-INSULATED WOOD DECK.
  
 2) THE ENHANCED FASTENING LETTER IS INCORRECT. ROOFING
 APPLICATION STANDARD 117 IS THE STANDARD SPECIFIED IN
 LIMITATION #7 OF THE PRODUCT APPROVAL NOA FOR
 DETERMINING THE SPACING OF THE FASTENERS AT THE
 PERIMETER AND CORNER . RAS 127 IS FOR TILE ROOFS AND
 RAS 150 IS A PRESCRIPTIVE STANDARD FOR BUR THAT WAS NOT
 ADOPTED BY THE CITY OF WEST PALM BEACH. PLEASE
 CORRECT.
  
 3) THE FASTENER SPACING OF 3" OC CENTER FOR THE BASE
 SHEET IS INCORRECT. THE BASE SHEET FASTENERS CAN NOT BE
 ANY CLOSER THAN 4" OC PER RAS 117. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-21 Cont ID  
Sent By rmcdouga Date 2008-05-21 Time 10:15 Rev Time 0.00
Received By rmcdouga Date 2008-05-21 Time 10:15 Sent To  
Notes
2008-05-21 10:20:59****CORRECTIONS****
 ROBERT MCDOUGAL, BUILDING PLANS EXAMINER
 561-805-6714 [email protected]
  
 2004 FLORIDA BUILDING CODE &
 CITY OF WEST PALM BEACH AMENDMENTS TO THE 2004 FBC
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE
 MITIGATION.
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 ____3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 __X__4.)FOR THE FLAT ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 __X__5.)FOR THE FLAT ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).
  
 ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.IF YOU SELECT FOAM
 ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72.
  
 ____ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
  
 PROVISO ? MECHANICAL EQUIPMENT TO COMPLY WITH FBC
 EB511, FBC1509.7.
  
  
 DOUBLE UNDERLAYMENT 1507.2.8
 DOUBLE UNDERLAYMENT TILE FBC R905.3.3.1, 2 ? / 12 UP TO
 4/12
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-21 Cont ID  
Sent By rmcdouga Date 2008-05-21 Time 10:21 Rev Time 0.00
Received By rmcdouga Date 2008-05-21 Time 10:21 Sent To  
Notes
***NONE***