Plan Review Details - Permit 08050492
Plan Review Stops For Permit 08050492
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-20 Cont ID  
Sent By amorse Date 2008-06-20 Time 15:48 Rev Time 0.00
Received By amorse Date 2008-06-20 Time 15:48 Sent To PC
Notes
2008-06-20 15:54:25 
  
 PASSED
  
 1)PLEASE NOTE THAT SHUTTER #3 (CLEAR PANEL) CANNOT BE
 INSTALLED VERTICALLY, THE MIN SHUTTER SPAN FOR ANY
 ATTACHMENT METHOD PER SHEET 3 OF THE PRODUCT APPROVAL
 IS 30". THIS SHUTTER MUST BE INSTALLED HORIZONTALLY OR
 BE A MIN OF 30" LONG IF INSTALLED VERTICAL.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-24 Cont ID  
Sent By amorse Date 2008-05-24 Time 08:15 Rev Time 0.00
Received By amorse Date 2008-05-24 Time 08:15 Sent To PC
Notes
2008-05-24 08:26:32 
  
 DENIED
  
 1)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE
 BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS
 DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN
 GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600
 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C
 CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND
 PRESSURES ACCORDINGLY, THIS WILL CHANGE THE O/C SPACING
 OF ANCHORS, ETC.
  
 ******NOTE PER TABLES R302.2.2(2) AND R302.2(3) OF FBC
 RES. STRUCTURES LOCATED IN EXPOSURE B WITH MEAN ROOF
 HEIGHT OF 30 FEET THAT ARE REQUIRED TO BE ADJUSTED FOR
 EXP C WILL BE MULTIPLIED BY A COEFFICIENT OF 1.40*****
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 11:03 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 11:03 Sent To B
Notes
2008-06-10 11:03:16TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-05-24 Time   Rev Time 0.00
Received By adarroug Date 2008-05-20 Time 10:05 Sent To  
Notes
2008-05-20 10:05:59TO "MISC" BOX#1