Plan Review Details - Permit 08050459
Plan Review Stops For Permit 08050459
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-01-07 Cont ID  
Sent By rmcdouga Date 2009-01-07 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2009-01-07 Time 16:53 Sent To  
Notes
2009-01-08 08:19:01BUILDING PROVISO
  
 SUBMIT 2 COPIES OF THE PRODUCT APPROVALS FOR THE ROOF
 COVERING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-09-09 Cont ID  
Sent By rmcdouga Date 2008-09-09 Time 09:54 Rev Time 0.00
Received By rmcdouga Date 2008-09-09 Time 09:54 Sent To E
Notes
2008-09-08 14:48:092004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) THE ADDITION TO THE EXISTING HOUSE IS REQUIRED TO BE
 INSULATED, HAVE ELECTRICAL WIRING, ETC. IN ORDER TO
 COMPLY WITH CODE AND WILL BE SUBSTANTIALLY COMPLETED,
 THEREFORE, A SHELL PERMIT CAN NOT BE ISSUED FOR THIS
 PROJECT. THE VALUE OF THE PROJECT HAS BEEN ADJUSTED TO
 ACCOUNT FOR THE REDUCTION IN SQUARE FOOTAGE TO 445
 SQFT. THE VALUE HAS BEEN ADJUSTED TO $47,067.00.
 ADDITIONAL PERMIT FEES OF $ 639.00 ARE DUE. SEE FBC
 108.3* CITY AMENDMENTS. FEES MUST BE PAID BEFORE PLANS
 ARE RELEASED.
  
 3) SUBMIT 2 COPIES OF A SURVEY THAT AGREES WITH THE
 DIMENSIONS OF THE SITE PLAN ON SHEET S-1.
  
 4) THE ENERGY CALCULATION FORM IS NOT FILLED OUT
 PROPERLY. IN ORDER TO USE FORM 600C-04R THE
 PRESCRIPTIVE METHOD THE MAXIMUM GLASS TO FLOOR AREA
 ALLOWED CAN NOT EXCEED 50 PERCENT. REVISE OPENINGS OR
 USE ANOTHER METHOD TO SHOW COMPLIANCE. THERE ARE NOT
 ANY WALLS OF THE ADDITION ADJACENT TO UNCONDITIONED
 SPACE SHOWN ON THE PLANS. THE CEILING INSULATION IS
 LISTED AS R3-0 ON THE FORM AND IT SHOULD BE R30. THE
 OWNER/AGENT IS REQUIRED TO SIGN THE FORM. PLEASE
 CORRECT. SEE FBC 13-600 METHOD C.
  
 5) THE PRODUCT APPROVALS HAVE BEEN CHANGED TO LARGE
 MISSILE IMPACT WINDOWS AND DOORS. THE STORM PANEL
 INSTALLATION SCHEDULE IS NO LONGER REQUIRED. PLEASE
 REMOVE IT FROM SUBMITTALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-05 Cont ID  
Sent By rmcdouga Date 2008-06-05 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2008-06-05 Time 06:55 Sent To  
Notes
2008-06-05 08:32:342004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE VALUE OF THE PROJECT SPECIFIED ON THE
 APPLICATION IS LOW. THE VALUE HAS BEEN ADJUSTED TO
 $54,154.00. ADDITIONAL PERMIT FEES OF $ 740.87 ARE DUE.
 SEE FBC 108.3* CITY AMENDMENTS.
  
 4) SUBMIT DETAILS FOR THE ATTACHMENT OF THE EXISTING
 FOUNDATION, WALLS AND TIE BEAM TO THE NEW ADDITION. FBC
 106.1.2* CITY AMENDMENTS
  
 5) SHOW COMPLIANCE WITH FBC R806.1 VENTILATION
 REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 /
 8 INCH (3.2 MM) MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM
 OPENINGS. R806.2 MINIMUM AREA.
 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
 THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED
 EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED
 TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE
 THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF
 THE SPACE TO BE VENTILATED AT LEAST 3 FEET (914 MM)
 ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE
 REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
 AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA
 MAY BE REDUCED TO 1 TO 300 WHEN A VAPOR BARRIER HAVING
 A TRANSMISSION RATE NOT EXCEEDING 1 PERM IS INSTALLED
 ON THE WARM SIDE OF THE CEILING. SPECIFY THE SIZE AND
 SPACING OF SOFFIT VENTS.
  
 6) THE ENERGY CALCULATION FORM IS NOT FILLED OUT
 PROPERLY. THE INFORMATION ON FORM 600C-04R APPLIES ONLY
 TO THE ADDITION. THE INFORMATION THAT WAS ENTERED IS
 FOR THE WHOLE HOUSE. ALSO, THE CEILING INSULATION IS
 SPECIFIED ON THE PLANS AS R-30 NOT R-19. PLEASE
 CORRECT. SEE FBC 13-600 METHOD C.
  
 7) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) THE PRODUCT APPROVAL NOA FOR THE FRENCH DOORS HAS
 BEEN REVISED BY NOA 05-1116.06. PLEASE SUBMIT THE NEW
 NOA.
  
 9) SUBMIT 2 COPIES OF A KEY PLAN AND INSTALLATION
 SCHEDULE INDICATING THE MOUNT TYPE, SPANS, ANCHOR TYPE
 AND SPACING, EDGE DISTANCE, ETC. SEE ATTACHED SAMPLE
 SCHEDULE. FBC 106.1.2* CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-09-17 Cont ID  
Sent By btrobaug Date 2008-09-17 Time 14:29 Rev Time 0.00
Received By btrobaug Date 2008-09-17 Time 14:15 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-05-20 Cont ID  
Sent By btrobaug Date 2008-05-20 Time 14:17 Rev Time 0.00
Received By btrobaug Date 2008-05-20 Time 14:05 Sent To M
Notes
2008-05-20 14:07:32 

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-15 Cont ID  
Sent By adarroug Date 2008-12-15 Time 15:14 Rev Time 0.00
Received By adarroug Date 2008-12-15 Time 15:14 Sent To Z
Notes
2008-12-15 15:15:05TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-02 Cont ID  
Sent By adarroug Date 2008-09-02 Time 12:35 Rev Time 0.00
Received By adarroug Date 2008-09-02 Time 12:35 Sent To Z
Notes
2008-09-02 12:36:13TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-05 Cont ID  
Sent By rmcdouga Date 2008-06-05 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2008-05-16 Time 15:49 Sent To  
Notes
2008-05-16 15:50:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-05-20 Cont ID  
Sent By tgordon Date 2008-05-20 Time 16:14 Rev Time 0.20
Received By tgordon Date 2008-05-20 Time 16:14 Sent To B
Notes
2008-05-20 16:14:47NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 4 Status P Date 2009-01-29 Cont ID  
Sent By mcruz Date 2009-01-29 Time 12:37 Rev Time 0.00
Received By mcruz Date 2009-01-29 Time 12:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2008-12-18 Cont ID  
Sent By mcruz Date 2008-12-18 Time 12:35 Rev Time 0.00
Received By mcruz Date 2008-12-17 Time 08:20 Sent To B
Notes
2008-12-18 12:25:33PLANNING AND ZONING DEPT: ***ZONING FAILED - 2ND
 RESUB***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 REPEAT COMMENT:
  
 2. THE SETBACK DIMENSIONS SHOWN ON THE SURVEY DIFFER
 FROM THE SETBACKS SHOWN ON THE SITE PLAN. PLEASE MAKE
 CONSISTENT.
  
 NEW COMMENT:
  
 3. PURSUANT TO THE SPENCER LAKES DECLARATIONS OF
 COVENANTS AND RESTRICTIONS, SECTION III.A. (PAGE 23):
 RESIDENTIAL USE. NO BUILDING OR OTHER IMPROVEMENT SHALL
 BE ERECTED UPON ANY LOT WITHOUT PRIOR ARCHITECTURAL
 REVIEW BOARD (A.R.B.) APPROVAL. SEE ATTACHED COPY.
  
 4. ENSURE THAT THE ROOF COMPLIES WITH THE FOLLOWING
 PROVISION LISTED IN SPENCER LAKES DECLARATIONS OF
 COVENANTS AND RESTRICTIONS, SECTION III.K. (PAGE 26):
 ALL ROOFS SHALL HAVE A MINIMUM PITCH OF 4 1/2 AND BE
 COVERED WITH TILE OR SHAKE SHINGLE ROOFING, EXCEPT AS
 OTHERWISE APPROVED BY THE A.R.B. FLAT ROOFS FOR THE
 REAR COVERED PORCHES SHALL BE PERMITTED.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2008-09-07 Cont ID  
Sent By mcruz Date 2008-09-07 Time 11:38 Rev Time 0.00
Received By mcruz Date 2008-09-07 Time 11:36 Sent To B
Notes
2008-09-07 11:37:56***ZONING FAILED 1ST RESUB***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PLEASE PROVIDE TWO (2) COPIES OF SURVEY. ONLY ONE
 (1) COPY WAS INCLUDED IN RESUB.
  
 3. THE SETBACK DIMENSIONS SHOWN ON THE SURVEY DIFFER
 FROM THE SETBACKS SHOWN ON THE SITE PLAN. PLEASE MAKE
 CONSISTENT.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-20 Cont ID  
Sent By choops Date 2008-05-20 Time 09:47 Rev Time 0.00
Received By choops Date 2008-05-20 Time 09:47 Sent To E
Notes
2008-05-20 09:51:37***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED TO ALL
 ADJACENT PROPERTY LINES.
  
 3)INDICATE A HEIGHT DIMENSION ON THE ELEVATION PAGE
 (SHEET S-3) OF THE PROPOSED SUN ROOM FROM GRADE.
  
 4)INDICATE OVERHANG DIMENSIONS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720