Plan Review Stops For Permit 08050419 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-27 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-27 |
Time |
12:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-06-16 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-06-16 |
Time |
10:27 |
Sent To |
|
|
Notes |
2008-06-16 10:35:19 | *****PROVISO***** | | | | | | PLANS TO BE FIRE-STAMPED WHEN THE MECHANICAL EXAMINER'S | | COMMENTS HAVE BEEN ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-05-22 |
Time |
22:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-05-22 |
Time |
19:21 |
Sent To |
|
|
Notes |
2008-05-22 22:36:43 | *****UNSAT***** | | | | | | 1.SEE MECHANICAL PLAN REVIEW COMMENT IN REFERENCE TO | | SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. | | | | 2.COOKING EQUIPMENT TO COMPLY WITH NFPA 96. | | | | 3. THE ADDRESS SHOWN IN THE TITLE BLOCK OF THE | | SUBMITTED PLAN SHEET REFERS TO BAY #1 WHICH IS NOT | | LISTED IN OUR PERMITTING SYSTEM. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-27 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-27 |
Time |
09:56 |
Sent To |
M |
|
Notes |
2008-08-27 09:57:02 | TO "MECH"TOM G. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-06-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-05 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-05 |
Time |
15:20 |
Sent To |
M |
|
Notes |
2008-06-05 15:21:21 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-05-22 |
Time |
19:21 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-05-15 |
Time |
14:19 |
Sent To |
|
|
Notes |
2008-05-15 14:19:43 | TO "M" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-08-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-27 |
Time |
12:19 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-08-27 |
Time |
12:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-06-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-06-06 |
Time |
10:53 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-06-06 |
Time |
10:53 |
Sent To |
FIRE |
|
Notes |
2008-06-06 11:12:02 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) AS NOTED IN LAST REVIEW 5-20-08. PLEASE SUBMIT | | DETAILED MANUFACTURER'S SPECIFICATION'S AND | | INSTALLATION INSTRUCTIONS FOR THE TYPE 2 HOOD, THAT | | SHOWS IT IS U.L. APPROVED, PER 2004 FBC/M 507.1 EXCEPT. | | WHAT WAS SUBMITTED IS INFORMATION ON SURELOCK GAS VENT | | PIPING. | | | | 2) PER 2004 FBC/M 507.2. A TYPE I OR TYPE II HOOD SHALL | | BE INSTALLED AT OR ABOVE ALL COMMERCIAL COOKING | | APPLIANCES IN ACCORDANCE WITH SECTIONS 507.2.1 AND | | 507.2.2 . WHERE ANY COOKING APPLIANCE UNDER A SINGLE | | HOOD REQUIRES A TYPE I HOOD, A TYPE I HOOD SHALL BE | | INSTALLED. WHERE A TYPE II HOOD IS REQUIRED, A TYPE I | | OR TYPE II HOOD SHALL BE INSTALLED | | | | 3) THIS COMMERCIAL COOKING APPLIANCE CAN NOT BE | | INSTALLED WITHOUT A HOOD, PER 2004 FBC/M 507. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-20 |
Time |
08:44 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-05-20 |
Time |
08:44 |
Sent To |
FIRE |
|
Notes |
2008-05-20 08:54:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) PLEASE SUBMIT DETAILED MANUFACTURER'S | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE | | TYPE 2 HOOD, THAT SHOWS IT IS U.L. APPROVED, PER 2004 | | FBC/M 507.1 EXCEPT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|