Plan Review Details - Permit 08050406
Plan Review Stops For Permit 08050406 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-30 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-30 |
Time |
09:54 |
Sent To |
|
|
Notes |
2008-05-30 09:58:58 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.ON THE EXISING HOUSE PLAN, SHOW ROOM DESIGNATIONS. | | IT IS NOT CLEAR WHETHER OR NOT BEDROOM EGRESS HAS BEEN | | AFFECTED. | | | | 2.PROVIDE A SITE PLAN WHICH DOES NOT HAVE OLD CITY | | PERMIT STAMPS ON IT. | | | | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | FOR THE ROOF PANELS, FAC9B72. | | | | 4. PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF | | RECORD (SHOP DRAWING REVIEW STAMP OR LETTER), | | FBC*106.3.3. | | | | 5.ADDITIONAL FEES DUE (RADON).PLEASE PAY PRIOR TO | | RESUBMITTAL. | | | | 6.PROVIDE A CURRENT SURVEY WHICH SHOWS THE PROPERTY | | LINES.THE SURVEY SUBMITTED IS DIFFICULT TO READ AND | | THE PROPERTY LINE IS NOT CLEARLY INDICATED.THIS | | APPEARS TO BE A PROPOSED SURVEY.(THE SURVEY SUBMITTED | | SHOWS FOUR UNITS ON ONE PARCEL; IT DOES NOT DESIGNATE | | THE UNITS' LOT LINES.) | | | | IN LIEU OF PROVIDING A CURRENT SURVEY, THE AERIAL | | AVAILABLE ON PAPA MAY BE PROVIDED.THE PLANS ARE TO | | CLEARLY SHOW THAT THE PROPOSED IMPROVEMENT WILL BE | | BUILT ENTIRELY WITHIN THIS LOT. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-30 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-15 |
Time |
12:57 |
Sent To |
|
|
Notes |
2008-05-15 12:57:17 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-05-19 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-19 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-19 |
Time |
09:18 |
Sent To |
B |
|
Notes |
2008-05-19 09:24:07 | ***FAILED*** | | | | | | 1)AS THE PROPOSED CONSISTS OF A SOLID ENCLOSED | | STRUCTURE, IT SHALL MEET THE PRINCIPAL STRUCTURE | | SETBACK REQUIREMENTS.AS PER ANDROS ISLES DESIGN | | GUIDELINES:MINIMUM REQUIRED REAR SETBACK = 10 FEET. | | | | 2)THERE ARE TWO DIMENSIONS LABELED ON THE SURVEY, | | WHAT/WHERE ARE THESE DIMENSIONS INDICATING?PLEASE | | CLARIFY AND SHOW COMPLIANCE WITH COMMENT #1. | | | | 3)PLEASE PROVIDE ANDROS ISLES HOA APPROVAL. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |