Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-06-25 Cont ID  
Sent By rbrown Date 2008-06-25 Time 13:45 Rev Time 0.00
Received By rbrown Date 2008-06-25 Time 13:45 Sent To  
Notes
2008-06-25 13:46:106/25/08 KERRY REQUESTED THAT THE SLIDING GLASS DOOR BE
 REMOVED FROM THE SCOPE OF THE PERMIT DUE TO PROBLEMS
 OBTAINING THE NECESSARY PRODUCT APPROVAL DOCUMENTS FROM
 THE MANUFACTURER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-19 Cont ID  
Sent By rbrown Date 2008-06-19 Time 10:33 Rev Time 0.00
Received By rbrown Date 2008-06-19 Time 10:33 Sent To  
Notes
2008-06-19 11:03:31REVIEW FOR SLIDING GLASS DOOR PRODUCT APPROVAL ONLY.
 ADRIAN MORSE IS THE PLAN REVIEWER FOR THIS PROJECT.
  
 ***NO FORMAL RESUBMITTAL OR FEE IS REQUIRED WHEN
 SUBMITTING THE INFORMATION REQUESTED BELOW***
  
 BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2004
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) FLORIDA ADMINISTRATIVE CODE RULE 9B-72.LOCAL
 PRODUCT APPROVAL.THE SUBMITTED PRODUCT APPROVAL
 APPLICATION FORM, SIGNED BY THOMAS TWOMEY, P.E., WAS
 HIGHLIGHTED AS A AN "APPLICATION FOR SITE SPECIFIC
 PRODUCT APPROVAL".PLEASE CIRCLE "LOCAL PRODUCT
 APPROVAL" INSTEAD.THE PROPOSED PLAZA DOOR CO, INC.,
 TITAN SERIES XII SLIDING GLASS DOOR IS NOT A
 CUSTOM/ONE-TIME USE PRODUCT.IT IS AN "OFF-THE-SHELF"
 PRODUCT AND SO MUST MEET THE REQUIREMENTS FOR LOCAL
 PRODUCT APPROVAL NOT SITE SPECIFIC PRODUCT APPROVAL.
 HOWEVER MOST OF THE REQUIRED DOCUMENTATION IS ALREADY
 IN PLACE (SEE THE FOLLOWING COMMENTS FOR THE ADDITIONAL
 DOCUMENTS NEEDED).
  
 2) FLORIDA ADMINISTRATIVE CODE RULE 9B-72.THIRD PARTY
 QUALITY ASSURANCE.ITEM 7 (THIRD PARTY QUALITY
 ASSURANCE ENTITY) OF THE PRODUCT APPROVAL APPLICATION
 FORM WAS NOT COMPLETED.PLEASE COMPLETE ITEM 7 OF THE
 FORM AND SUBMIT THE FOLLOWING DOCUMENTATION.FOR LOCAL
 PRODUCT APPROVAL PLEASE SUBMIT DOCUMENTATION SHOWING
 THAT A PLAZA DOOR CO, INC., HAS A QUALITY ASSURANCE
 AGREEMENT WITH AN APPROVED THIRD PARTY QUALITY
 ASSURANCE ENTITY, FOR ALL OF IT'S PRODUCTS OR FOR THE
 TITAN SERIES XII SLIDING GLASS DOOR SPECIFICALLY.
 APPROVED THIRD PARTY QUALITY ASSURANCE ENTITIES ARE
 LISTED ON THE FLORIDA STATE PRODUCT APPROVAL WEBSITE.
  
 3) FLORIDA ADMINISTRATIVE CODE RULE 9B-72.EVALUATION
 REPORT/LETTER.THE SUBMITTAL OF SIGNED AND SEALED
 CALCULATIONS FROM THOMAS TWOMEY, P.E., IS NOTED.
 HOWEVER FOR LOCAL PRODUCT APPROVAL AN EVALUATION
 REPORT/LETTER IS REQUIRED STATING THAT HE HAS REVIEWED
 THE PRODUCT INFORMATION AND TEST REPORT, AND IN HIS
 PROFESSIONAL OPINION THE TITAN SERIES XII SLIDING GLASS
 DOOR MEETS THE WIND LOAD AND MISSILE IMPACT PROTECTION
 REQUIREMENTS OF FLORIDA BUILDING CODE 2004.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE:
 (561) 805 6652ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-20 Cont ID  
Sent By amorse Date 2008-05-20 Time 17:43 Rev Time 0.00
Received By amorse Date 2008-05-20 Time 17:43 Sent To PC
Notes
2008-05-20 17:52:59 
  
 DENIED
  
 1)THE TITAN XII SGD DOES NOT CARRY AN APPROVED STATUS
 WITH THE DCA STATEWIDE PRODUCT APPROVAL SYSTEM AND
 LIKEWISE DOES NOT HAVE MIAMI-DADE APPROVAL. EITHER AN
 APPROVED PRODUCT MUST BE USED OR PRODUCT MAY BE
 SUBMITTED FOR LOCAL PRODUCT APPROVAL (PLEASE SEE
 ATTACHED APPLICATION) NOTE THAT THE BACK OF THE FORM
 HAS A CHECKLIST AND ALL INFORMATION MUST INCLUDED WITH
 THE APPLICATION TO BE REVIEWED BY THE BUILDING
 OFFICIAL.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-06 Cont ID  
Sent By adarroug Date 2008-06-06 Time 08:35 Rev Time 0.00
Received By adarroug Date 2008-06-06 Time 08:35 Sent To B
Notes
2008-06-06 08:35:53TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-05-20 Time   Rev Time 0.00
Received By adarroug Date 2008-05-15 Time 10:50 Sent To  
Notes
2008-05-15 10:50:51TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***