Plan Review Stops For Permit 08050185 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-06-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-06-12 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-06-12 |
Time |
11:10 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-05-20 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-05-20 |
Time |
07:40 |
Sent To |
E |
|
Notes |
2008-05-20 09:59:49 | RESIDENTIAL (R3) NEW POOL CONSTRUCTION, BUILDING REVIEW | | CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1-CLEARLY SPECIFY HOW COMPLYING WITH THE RESIDENTIAL | | SWIMMING BARRIER REQUIREMENT SEC. R4101.17 OF 2004 | | FLORIDA RESIDENTIAL CODE. NEED TO SPECIFY HOW IMPEDING | | ACCESS FROM THE HOME TO THE POOL AND HOW IMPEDING | | ACCESS FROM OUTSIDE TO THE POOL. NOTE PROVIDE ON PLANS | | STATES THAT ONLY ONE SAFETY FEATURE IS REQUIRED TO | | COMPLYWITH THIS SECTION.ONLY ONE FEATURE WILL NOT | | COMPLY WITH BOTH REQUIREMENTS OF PROVIDING ACCESS TO | | THE POOL FROM THE HOUSE OR FROM OUTSIDE. REVISE NOTE AS | | REQUIRED., INCLUDING CITING CORRECT CODE SECTION. USE | | 2004 FLORIDA RESIDENTIAL CODE SECTION CITED ABOVE, | | WHICH IS THE ONE THAT CORRESPONDS TO THIS RESIDENTIAL | | POOL. | | | | ***NOTE: SEE ZONING COMMENTS REGARDING FENCE AROUND THE | | HOUSE. | | | | 2- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. | | VALUATION WAS UPDATEDTO $33,124(WHICH INCLUDES THE | | POOL, POOL SPA, POOL HEATER AND PAVERS)AS REQUIRED | | BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004.OWES | | $669.10WHICH IS THE TOTALFEE FOR THE PERMIT. | | CONTRACTOR DID NOT PAID THE PERMIT FEES AT TIME OF | | PERMIT APPLICATION. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-20 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-05-13 |
Time |
11:17 |
Sent To |
I |
|
Notes |
2008-05-20 13:44:50 | | | | | PROVISO | | | | THE DETAIL FOR THE EQUIPOTENTIAL BONDING MUST BE A WET | | SIGNATURE, SEALED AND DATED WITH THE CURRENT DATE THAT | | IT IS SEALED. PLEASE INCLUDE TWO COPIES OF SAME WHEN | | RESUBMITTING FOR OTHER COMMENTS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-05-14 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-14 |
Time |
14:42 |
Sent To |
B |
|
Notes |
2008-05-14 14:44:55 | **CONTRACTOR INFORMATION ONLY** | | NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL | | GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL | | INSPECTION. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-02-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-12 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-12 |
Time |
16:05 |
Sent To |
P |
|
Notes |
2009-02-12 16:05:30 | TO "P" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-01-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-13 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-13 |
Time |
10:08 |
Sent To |
P |
|
Notes |
2009-01-13 10:08:46 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-17 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-17 |
Time |
10:51 |
Sent To |
Z |
|
Notes |
2008-07-17 10:52:40 | TO "Z" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-06-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-10 |
Time |
09:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-10 |
Time |
09:29 |
Sent To |
Z |
|
Notes |
2008-06-10 09:29:19 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-20 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-05-07 |
Time |
15:28 |
Sent To |
PC |
|
Notes |
2008-05-07 15:29:13 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-03-30 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-03-30 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-03-30 |
Time |
09:10 |
Sent To |
|
|
Notes |
2009-03-30 09:21:59 | REVISION OK |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2009-02-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-03 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-03 |
Time |
11:46 |
Sent To |
|
|
Notes |
2009-02-03 11:51:37 | DENIED | | REFERENCE: | | FBC-2004 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. ALL REVISIONS TO A SIGNED, SEALED SET OF PLANS SHALL | | BE SIGNED, SEALED AND DATED BY THE ENGINEER OF RECORD. | | SECTION 106.1, FAC 61G15-23.002 & FS 471.025. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-20 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-14 |
Time |
14:40 |
Sent To |
G |
|
Notes |
2008-05-14 14:42:20 | ****************PROVISO**************** | | FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. | | R4101.9 WATER SUPPLY, LOCAL ORD. | | #2853-95, BACKFLOW REQUIRED ON WATER | | SERVICE.(ADD TO NOTES) | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-07-23 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2008-07-23 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-06-11 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-06-11 |
Time |
09:22 |
Sent To |
B |
|
Notes |
2008-06-11 09:23:45 | ***FAILED - RESUB #1*** | | | | | | REPEAT COMMENTS: | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | PLANS INDICATE DIMENSIONS TO EASEMENTS...WHAT | | EASEMENTS, DO YOU MEAN PROPERTY LINES?WHERE ARE THESE | | DIMENSIONS FROM...THE POOL EQUIPMENT? | | | | 2)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | "CHILD BARRIERS" DO NOT SATISFY THE ZONING REQUIREMENT | | FOR A PERMANENT FENCE ENCLOSURE. | | | | | | NEW COMMENTS: | | | | 1)ALL PLANS/DIMENSIONS SHALL BE DONE WITH A PERMANENT | | UTENSIL (NOT PENCIL). | | | | | | NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT | | TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "B" - JG |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-05-09 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-09 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-09 |
Time |
13:16 |
Sent To |
E |
|
Notes |
2008-05-09 13:18:25 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 2)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | HEIGHT ABOVE GRADE. | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT | | TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|