Plan Review Stops For Permit 08040848 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-01 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-01 |
Time |
17:28 |
Sent To |
|
|
Notes |
2008-05-01 17:29:13 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | _XX_6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE | | FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-08-18 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-08-18 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-06-11 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-06-11 |
Time |
14:27 |
Sent To |
|
|
Notes |
2008-06-11 14:30:15 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 4.THE LANGUAGE FOR THE ANCHORS YOU HAVE SPECIFIED ON | | THE INSTALLATION SCHEDULE DOES NOT MATCH THE | | DESCRIPTION FOR ANCHORS ON THE PRODUCT APPROVAL, SEE | | SHEET 7.PLEASE CLARIFY WHICH ANCHOR YOU ARE USING. | | | | THE INSTALLATION SCHEDULE STATES MAXISET, THE PRODUCT | | APPROVAL ANCHOR SCHEDULE SPECIFIES TO ITW.PLEASE | | CORRELATE. | | | | NEW COMMENT: | | | | 2.SEE OPENING 3, CLARIFY SPAN.HOW CAN THIS HAVE A | | HEIGHT OF 122" BUT A SPAN OF 75"; SPAN IS TO BE BLADE | | LENGTH?PLEASE CHECK ALL AND REVISE ANCHOR SPACING AS | | NEEDED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-15 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-15 |
Time |
11:48 |
Sent To |
|
|
Notes |
2008-05-15 11:58:05 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | 1.RE: PREVIOUS COMMENT #3, INSTALLATION SCHEDULE, TWO | | SETS REQUIRED. PLEASE PROVIDE TWO SETS.CONTRACTORS | | ARE TO PROVIDE TWO COMPLETE COLLATED SETS OF DOCUMNTS | | FOR PERMIT ISSUANCE.ONLY ONE SET OF THE INSTALLATION | | SCHEDULE WAS PROVIDED; EACH SHEET STAPLED TO A FLOOR | | PLAN. | | | | 2.DESIGN PRESSURES HAVE NOT BEEN DECLARED ON ONE OF | | THE SHEETS; ARE YOU USING THE SAME FOR THE ENTIRE JOB? | | | | 3.SEE OPENING 9.A SPAN OF 116, DESIGN PRESSURE | | 70.6, C2/C4 SHOULD HAVE ANCHOR SPACING OF 6IN/4IN (NOT | | 10IN/6IN AS SPECIFIED) IF YOU ARE USING THE TAPCON | | CIRCLED ON THE PRODUCT APPROVAL. | | | | 4.THE LANGUAGE FOR THE ANCHORS YOU HAVE SPECIFIED ON | | THE INSTALLATION SCHEDULE DOES NOT MATCH THE | | DESCRIPTION FOR ANCHORS ON THE PRODUCT APPROVAL, SEE | | SHEET 7.PLEASE CLARIFY WHICH ANCHOR YOU ARE USING. | | | | 5.ITEMS ARE CIRCLED ON THE PRODUCT APPROVAL WHICH DO | | NOT CORRELATE WITH THE JOB.PLEASE PROVIDE INFORMATION | | SPECIFIC TO THIS JOB ONLY. | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-01 |
Time |
11:58 |
Rev Time |
|
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2008-05-15 11:59:02 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | _XX_6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE | | FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-08-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-12 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-12 |
Time |
16:46 |
Sent To |
B |
|
Notes |
2008-08-12 16:47:09 | TO "SHILL 'DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-06 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-06 |
Time |
16:06 |
Sent To |
B |
|
Notes |
2008-06-06 16:06:22 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-14 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-14 |
Time |
11:30 |
Sent To |
B |
|
Notes |
2008-05-14 11:30:49 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-01 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-01 |
Time |
15:31 |
Sent To |
|
|
Notes |
2008-05-01 15:31:55 | TO "MISC" BOX#1 |
|
|