Plan Review Details - Permit 08040847
Plan Review Stops For Permit 08040847 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-05-08 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-05-07 |
Time |
18:07 |
Sent To |
|
|
Notes |
2008-05-07 18:09:24 | 2004 FBC W/2007 REVISIONS | | SITE BUILT SHED | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | BE REQUIRED. | | | | 2) THE SEAL THAT THE ENGINEER USED TO SEAL THE PLANS IS | | NO LONGER ACCEPTABLE. THE FLORIDA BOARD OF ENGINEER'S | | REVISED THE SEALS AND AS OF JANUARY 1, 2006, THE SEAL | | MUST HAVE LICENSE IN PLACE OF CERTIFICATE. SEE FAC | | 61G15-23.001 FOR REQUIREMENTS. | | | | 3) SPECIFY THE CONNECTORS FOR THE WALL STUD TO TOP AND | | BOTTOM PLATE CONNECTIONS TO PROVIDE A CONTINUOUS LOAD | | PATH FROM THE ROOF FOUNDATION. SEE FBC R301.1. | | | | 4) SPECIFY THE SPACING OF THE 18 GA. ANGLES AT THE | | BOTTOM PLATE TO FLOOR FRAMING CONNECTION. FBC R301.1 | | | | 5) SHOW COMPLIANCE WITH FBC R703.1 FOR A | | WATER-RESISTIVE BARRIER AT THE EXTERIOR WALLS. | | | | 6)THIS SHED IS NOT LISTED AS A MANUFACTURED BUILDING | | AND THEREFORE, IS REQUIRED TO BE CONSTRUCTED ON SITE | | WITH ALL REQUIRED INSPECTIONS PERFORMED BY CITY | | BUILDING DEPARTMENT INSPECTORS. SEE FBC 109.1* CITY | | AMENDMENTS. | | | | 7) SUBMIT INSTALLATION INSTRUCTIONS FOR THE WINDOWS. | | SEE DCA RULE 9B-72 | | | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-05-08 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-05-01 |
Time |
15:07 |
Sent To |
|
|
Notes |
2008-05-01 15:07:12 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-05-06 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-06 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-06 |
Time |
09:45 |
Sent To |
B |
|
Notes |
2008-05-06 09:48:06 | ***FAILED*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A LEGIBLE SURVEY. | | | | 2)INDICATE SEPARATION DISTANCE FROM PRINCIPAL | | STRUCTURE TO THE PROPOSED SHED. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|