Plan Review Details - Permit 08040845
Plan Review Stops For Permit 08040845
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2008-05-13 Cont ID  
Sent By tgordon Date 2008-05-13 Time 10:57 Rev Time 0.00
Received By tgordon Date 2008-05-13 Time 10:57 Sent To  
Notes
2008-05-13 10:57:39SCOPE OF WORK REVISED TO INCLUDE ONLY THE 3 TO 5 TON
 CONDENSER UNITS ONLY, AND NOT THE 50 TON CHILLER UNITS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-02 Cont ID  
Sent By jwitmer Date 2008-05-02 Time 11:21 Rev Time 2.25
Received By jwitmer Date 2008-05-02 Time 11:20 Sent To PC
Notes
2008-05-02 12:25:45BUILDING PLAN REVIEW
 PERMIT: 08040845
 ADD: 2450 PRESIDENTIAL WAY
 CONT: WALLEN SERVICES
 TEL: (561)684-5555
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS.
  
 2)ATLANTIC & CARIBBEAN ROOF CONSULTING, LLC,
 INDICATES THAT THEY ARE OFFERING ENGINEERING SERVICES,
 AND WILL NEED TO MEET THE REQUIREMENTS OF 61G15-23.002
 (2)FL. ADMIN. CODE. A COVER SHEET OR INDEX SHEET FOR
 ENGINEERING SPECIFICATIONS MAY BE USED AND THAT SHEET
 MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION
 & PREPARATION OF EACH SECTION OF THE ENGINEERING
 SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER
 SHEET OR INDEX. OR SIGN & SEAL EACH SHEET INDIVIDUALLY
 WITHIN THE REPORT.
  
 3) PLANS AND CALCULATION INDICATE ANY HORIZONTAL
 FRAMING MEMBERS ON DETAIL THE CURRENT DETAIL MAKES IT
 APPEAR THAT THE ROOF TOP COOLING UNIT WILL SIT AND
 ATTACH DIRECTLY TO THE FOR VERTICAL COLUMNS.
 ADDITIONAL INFORMATION IS REQUIRED 106.1.2. HOW WILL
 THE MECHANICAL UNIT BE SECURED TO THE SUPPORTING STEEL
 FRAME?
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-02 Cont ID  
Sent By jwitmer Date 2008-05-02 Time 11:21 Rev Time 0.00
Received By jwitmer Date 2008-05-01 Time 10:18 Sent To  
Notes
2008-05-01 10:18:42TO "M" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-05-13 Cont ID  
Sent By tgordon Date 2008-05-13 Time 10:54 Rev Time 0.25
Received By tgordon Date 2008-05-13 Time 10:54 Sent To  
Notes
2008-05-13 10:56:53SCOPE OF WORK REVISED TO INCLUDE ONLY THE 3 TO 5 TON
 CONDENSER UNITS ONLY, AND NOT THE 50 TON CHILLER UNITS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-02 Cont ID  
Sent By tgordon Date 2008-05-02 Time 10:31 Rev Time 0.45
Received By tgordon Date 2008-05-02 Time 10:31 Sent To B
Notes
2008-05-02 10:43:32PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) WORKING ON A 50 TON COOLING CAPACITY CHILLER IS NOT
 WITHIN THE SCOPE OF YOUR LICENSE #CACA15692 CLASS B.
 WORKING ON A 50 TON CHILLER REQUIRES A CLASS A
 LICENSE.
  
  
 ** FLORIDA STATUTE 489.105 (3) (G)"CLASS B
 AIR-CONDITIONING CONTRACTOR" MEANS A CONTRACTOR WHOSE
 SERVICES ARE LIMITED TO 25 TONS OF COOLING AND 500,000
 BTU OF HEATING IN ANY ONE SYSTEM IN THE EXECUTION OF
 CONTRACTS REQUIRING THE EXPERIENCE, KNOWLEDGE, AND
 SKILL TO INSTALL, MAINTAIN, REPAIR, FABRICATE, ALTER,
 EXTEND, OR DESIGN, WHEN NOT PROHIBITED BY LAW, CENTRAL
 AIR-CONDITIONING, REFRIGERATION, HEATING, AND
 VENTILATING SYSTEMS, INCLUDING DUCT WORK IN CONNECTION
 WITH A COMPLETE SYSTEM ONLY TO THE EXTENT SUCH DUCT
 WORK IS PERFORMED BY THE CONTRACTOR AS IS NECESSARY TO
 MAKE COMPLETE AN AIR-DISTRIBUTION SYSTEM BEING
 INSTALLED UNDER THIS CLASSIFICATION, AND ANY DUCT
 CLEANING AND EQUIPMENT SANITIZING WHICH REQUIRES AT
 LEAST A PARTIAL DISASSEMBLING OF THE SYSTEM; TO
 INSTALL, MAINTAIN, REPAIR, FABRICATE, ALTER, EXTEND, OR
 DESIGN, WHEN NOT PROHIBITED BY LAW, PIPING AND
 INSULATION OF PIPES, VESSELS, AND DUCTS; TO REPLACE,
 DISCONNECT, OR RECONNECT POWER WIRING ON THE LOAD SIDE
 OF THE DEDICATED EXISTING ELECTRICAL DISCONNECT SWITCH;
 TO INSTALL, DISCONNECT, AND RECONNECT LOW VOLTAGE
 HEATING, VENTILATING, AND AIR-CONDITIONING CONTROL
 WIRING; AND TO INSTALL A CONDENSATE DRAIN FROM AN
 AIR-CONDITIONING UNIT TO AN EXISTING SAFE WASTE OR
 OTHER APPROVED DISPOSAL OTHER THAN A DIRECT CONNECTION
 TO A SANITARY SYSTEM. THE SCOPE OF WORK FOR SUCH
 CONTRACTOR SHALL ALSO INCLUDE ANY EXCAVATION WORK
 INCIDENTAL THERETO, BUT SHALL NOT INCLUDE ANY WORK SUCH
 AS LIQUEFIED PETROLEUM OR NATURAL GAS FUEL LINES WITHIN
 BUILDINGS, EXCEPT FOR DISCONNECTING OR RECONNECTING
 CHANGEOUTS OF LIQUEFIED PETROLEUM OR NATURAL GAS
 APPLIANCES WITHIN BUILDINGS; POTABLE WATER LINES OR
 CONNECTIONS THERETO; SANITARY SEWER LINES; SWIMMING
 POOL PIPING AND FILTERS; OR ELECTRICAL POWER WIRING.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved