Plan Review Details - Permit 08040811
Plan Review Stops For Permit 08040811
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-08 Cont ID  
Sent By rmcdouga Date 2008-08-08 Time 13:23 Rev Time 0.00
Received By rmcdouga Date 2008-08-08 Time 13:23 Sent To  
Notes
2008-08-08 13:26:20NEW PRODUCT APPROVALS WERE SUBMITTED FOR ONE HOUR FIRE
 RATED GLASS BLOCK ASSEMBLY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-24 Cont ID  
Sent By rmcdouga Date 2008-06-24 Time 09:38 Rev Time 0.00
Received By rmcdouga Date 2008-06-24 Time 09:38 Sent To  
Notes
2008-06-23 16:57:32BUILDING PROVISO
  
 SUBMIT TWO COPIES OF THE LISTING INFORMATION FOR THE
 ONE HOUR FIRE RATED GLASS BLOCK SYSTEM THAT IS REQUIRED
 ON THE ZERO LOT LINE, BEFORE INSTALLATION. THE PRODUCT
 APPROVAL SUBMITTED IS FOR A SILICONE SYSTEM. FBC
 106.1.2* CITY AMENDMENTS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-06 Cont ID  
Sent By rmcdouga Date 2008-05-06 Time 17:58 Rev Time 0.00
Received By rmcdouga Date 2008-05-06 Time 07:11 Sent To  
Notes
2008-05-06 17:37:512004 FBC W/2007 REVISIONS
 NEW SINGLE FAMILY DWELLING
  
 DENIED BY BUILDING
  
 1)FBC R401.4AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 2) THE NAIL SIZE FOR ROOF SHEATHING SPECIFIED IN THE
 SCHEDULE ON SHEET D-1 IS FOR AN 8D COMMON NAIL. THE
 PLANS SPECIFY 10D NAILS ON A-5.0. FBC R803.2.3.1 OF
 2006 REVISIONS TO 2004 FBC RESIDENTIAL CODE REQUIRES 8D
 RING-SHANK NAILS.
  
 3) THE TYPICAL WALL SECTION ON D-1 SHOWS AN 18" X 16"
 FOOTING AND THE SCHEDULE ON A-1.0 SPECIFIES A 16" X 16"
 FOOTING. PLEASE CLARIFY. FBC 106.1.1* CITY AMENDMENTS
  
 4)THE NAILING SCHEDULE FOR PNEUMATIC FASTENERS ON
 SPECIFIES A SPACING OF 16" OC FOR DOOR AND GARAGE DOOR
 BUCKS. DETAIL 8 ON D-1 AND 2 ON D-2 SPECIFY 12" OC.
 PLEASE CORRECT. FBC 106.1.1* CITY AMENDMENTS
  
 5) NOTE: SOME OF THE FASTENERS LISTED IN THE SCHEDULE
 ARE NOT PNEUMATIC FASTENERS.
  
 6) SUBMIT THE LISTING INFORMATION FOR THE ONE HOUR FIRE
 RATED GLASS BLOCK SYSTEM THAT IS REQUIRED ON THE ZERO
 LOT LINE. THE PRODUCT APPROVAL SUBMITTED IS FOR A
 SILICONE SYSTEM. FBC 106.1.2* CITY AMENDMENTS
  
 7) THE LARGE GLASS BLOCK OPENING ON THE PLANS EXCEEDS
 THE MAXIMUM OPENING SIZE OF 6' X 6' ALLOWED BY THE
 PRODUCT APPROVAL. DCA RULE 9B-72
  
 8) THE DOOR SCHEDULE ON A-2.0 SPECIFIES AN OXXO DOOR
 FOR THE 9' X 8' SLIDING GLASS DOOR. THE FLOOR PLAN AND
 ELEVATIONS SHOW A THREE PANEL DOOR. PLEASE CLARIFY.
  
 9) WINDOWS #7 AND #5 IN THE SCHEDULE ON A-2.0 WILL BE
 REQUIRED TO USE GLASS TYPES B OR D FROM THE PRODUCT
 APPROVALS IN ORDER TO MEET THE REQUIRED OPENING
 PRESSURES. FBC TABLES R301.2(2) AND R301.2(3).
  
 10) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO SECURE THE ROOF TILES. THE HACIENDA TILE SELECTED IN
 THE PRODUCT APPROVAL HAS A REQUIRED AERODYNAMIC UPLIFT
 MOMENT OF 37 PER TABLE 6 OF THE EVALUATION REPORT. IF
 ADHESIVE IS USED, SUBMIT PRODUCT APPROVALS. FBC R 905.3
 AND FBC 106.1.1* CITY AMENDMENTS
  
 11) A SEPARATE PERMIT WILL BE REQUIRED FOR THE
 DRIVEWAY/APPROACH.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-10-15 Cont ID  
Sent By btrobaug Date 2008-10-15 Time 14:17 Rev Time 0.00
Received By btrobaug Date 2008-10-15 Time 14:16 Sent To PC
Notes
2008-10-15 14:17:06 
  
 REMOVED POOL PANEL./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-06-12 Cont ID  
Sent By btrobaug Date 2008-06-12 Time 11:40 Rev Time 0.00
Received By btrobaug Date 2008-06-12 Time 10:05 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-05-02 Cont ID  
Sent By btrobaug Date 2008-05-02 Time 15:04 Rev Time 0.00
Received By btrobaug Date 2008-05-02 Time 12:15 Sent To M
Notes
2008-05-02 15:04:02 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER
 1AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
  
 1} THE AHU CIRCUITS IN PANEL "A"ARE RATED AT 5000 W
 WITH 60 AMP OCP IN VIOLATION OF 310.16. THESE 5000W
 LOADS DO NOT CORRELATE WITH THE MANUFACTURERS
 SPECIFICATIONS ON SHEET M-1, CORRELATE SAME.
  
 2} THE CIRCUIT (1,3) PANEL "B" FOR CONDENSER #1 @50
 AMPS EXCEEDS THE MANUFACTURERS MAX FUSE SIZE ON SHEET
 M-1
  
 3} THERE IS A JACUZZI IN THE MASTER BATH THAT IS NOT IN
 THE PANEL SCHEDULE PER 408.4.
  
 4} INDICATE COMPLIANCE WITH 680.43(A)(1-4) FOR
 RECEPTACLES FOR THE JACUZZI.
  
 5} THE LOAD CALCULATION MUST REFLECT THE CHANGES FROM
 THE AHU AND JACUZZI. 220.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-02-27 Cont ID  
Sent By adarroug Date 2009-02-27 Time 10:25 Rev Time 0.00
Received By adarroug Date 2009-02-27 Time 10:25 Sent To Z
Notes
2009-02-27 10:25:55TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-10-10 Cont ID  
Sent By adarroug Date 2008-10-10 Time 09:07 Rev Time 0.00
Received By adarroug Date 2008-10-10 Time 09:07 Sent To E
Notes
2008-10-10 09:08:10TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-08-07 Cont ID  
Sent By shill Date 2008-08-07 Time 15:26 Rev Time 0.00
Received By shill Date 2008-08-07 Time 15:26 Sent To B
Notes
2008-08-07 15:26:58TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-01 Cont ID  
Sent By adarroug Date 2008-07-01 Time 09:54 Rev Time 0.00
Received By adarroug Date 2008-07-01 Time 09:54 Sent To Z
Notes
2008-07-01 09:54:46TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 10:34 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 10:34 Sent To Z
Notes
2008-06-10 10:34:59TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-06 Cont ID  
Sent By rmcdouga Date 2008-05-06 Time 18:04 Rev Time 0.00
Received By rmcdouga Date 2008-05-01 Time 08:16 Sent To  
Notes
2008-05-01 08:16:16TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2009-03-02 Cont ID  
Sent By rkussner Date 2009-03-02 Time 12:19 Rev Time 0.00
Received By rkussner Date 2009-03-02 Time 09:29 Sent To Z
Notes
2009-03-02 12:21:41***LANDSCAPE REVIEW PASSED WITH THE FOLLOWING PROVISO.
  
 1. PROVIDE REQUIRED STREET TREES TO BE CONSISTENT WITH
 THE BALANCE OF STREET.
  
 2. GRAVEL SHALL BE CONTAINED AND KEPT AWAY FROM TREES
 AND SHRUB BEDS.
  
 3. HARDSCAPE ELEMENTS (DECKS, POOLS, DRIVES, ETC.)
 SHALL BE ACCURATELY SHOWN ON PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-05-02 Cont ID  
Sent By tgordon Date 2008-05-02 Time 15:56 Rev Time 0.45
Received By tgordon Date 2008-05-02 Time 15:56 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-06-19 Cont ID  
Sent By mperson Date 2008-06-19 Time 09:09 Rev Time 0.00
Received By mperson Date 2008-06-19 Time 09:09 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-05-02 Cont ID  
Sent By mperson Date 2008-05-02 Time 09:48 Rev Time 0.00
Received By mperson Date 2008-05-02 Time 09:48 Sent To E
Notes
2008-05-02 11:19:35PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1.0 SANITARY RISER DIAGRAM: PER FBC-2004
 PLUMBING SECTION 406.3 WASTE CONNECTIONS. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL CONNECT TO A BRANCH
 DRAIN OR DRAINAGE STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
  
 2. SHEET A-1.0 SANITARY RISER DIAGRAM: BATHROOM #2
 DOES NOT REFLECT THE FLOOR PLAN ON SHEET A-2.0. THE
 FLOOR PLAN ON SHEET A-2.0 INDICATES ONE SHOWER FOR THIS
 BATHROOM HOWEVER THE ISOMETRIC ON SHEET A-1.0 IS
 INDICATING TWO SHOWERS. ALSO THE LAVATORY TRAP ON SHEET
 A-1.0 ISOMETRIC IS BEING INDICATED IN THE WRONG ROOM.
 PLEASE CORRECT THE ISOMETRIC ON SHEET A-1.0 FOR
 BATHROOM #2 TO REFLECT THE FLOOR PLAN ON SHEET A-2.0.
 PER FBC-2004 PLUMBING SECTION 701.1 SCOPE.
  
 3. SHEET A-2.0 FLOOR PLAN GARAGE: PLEASE PROVIDE A
 DETAIL ON HOW THE GAS WATER HEATER WILL BE PROTECTED
 FROM PHISICAL DAMAGE FROM VEHICLE IMPACT. PER FBC-2004
 FUEL GAS SECTION 303.4 PROTECTION FROM PHYSICAL
 DAMAGE.
  
 4. SHEET D-2PLUMBING NOTES: STATES THE FOLLOWING
 "MINIMUM SLOPE SHALL BE 1/8" PER FOOT". PLEASE CLEARLY
 INDICATE THE MINIMUM SLOPE OF HORIZONTAL DRAINAGE
 PIPING SHALL BE PER FBC-2004 W/07 REVISIONS PLUMBING
 TABLE 704.1. 2-1/2" OR LESS SHALL BE 1/4" PER FOOT
 SLOPE, 3" TO 6" SHALL BE 1/8" PER FOOT SLOPE AND 8" OR
 LARGER SHALL BE 1/16" PER FOOT SLOPE.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2008-07-02 Cont ID  
Sent By choops Date 2008-07-02 Time 10:49 Rev Time 0.00
Received By choops Date 2008-07-02 Time 10:49 Sent To PC
Notes
2008-07-02 10:50:05***APPROVED - RESUB #2***
  
 NOTE:PLANT MATERIALS USED SHALL BE EQUAL TO OR
 BETTER THAN FLORIDA DEPARTMENT OF AGRICULTURE NUMBER 1
 NURSERY GRADE STANDARD.
  
 NOTE:THE REQUIRED IRRIGATION SYSTEM SHALL BE
 PROVIDED IN THE YARD AREA AND ANY SWALE/PARKWAY AREA,
 IF APPLICABLE.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-06-11 Cont ID  
Sent By choops Date 2008-06-11 Time 09:50 Rev Time 0.00
Received By choops Date 2008-06-11 Time 09:50 Sent To E
Notes
2008-06-11 09:59:23***FAILED - RESUB #1***
  
  
 REPEAT COMMENT:
  
 1)PLEASE SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE
 WITH SECTIONS 94-442 AND 94-445 OF THE CITY'S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS).
  
 THE SUBMITTED PLAN DOES NOT PROVIDE SUFFICIENT
 SHADE/FLOWER/FRUIT TREES, AND MANY OF THE LANDSCAPE
 CALCULATIONS ARE INACCURATE.PLEASE SEE LANDSCAPE PLAN
 WITH NOTED CORRECTIONS/CALCULATIONS...TOTAL LOT AREA
 NOT CORRECT, REQUIRED SHADE TREES NOT CORRECT, VARIOUS
 OTHER CALCULATIONS NOT CORRECT...PLANS SHALL REFLECT
 CORRECT CALCULATIONS AND AN ADDITIONAL SHADE TREE SHALL
 BE PROVIDED.
  
 NOTE:FOR SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE
 SHADE, FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR
 EACH 1,200 SQUARE FEET OF OPEN SPACE OR PORTION
 THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE
 SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN
 SPACE OR PORTION THEREOF.
  
 NOTE:PLANT MATERIALS USED PURSUANT TO THE PROVISIONS
 OF THIS SECTION SHALL BE EQUAL TO OR BETTER THAN
 FLORIDA DEPARTMENT OF AGRICULTURE NUMBER 1 NURSERY
 GRADE STANDARD.
  
 NOTE:THE REQUIRED IRRIGATION SYSTEM SHALL BE
 PROVIDED IN THE YARD AREA AND ANY SWALE/PARKWAY AREA,
 IF APPLICABLE.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-01 Cont ID  
Sent By choops Date 2008-05-01 Time 13:46 Rev Time 0.00
Received By choops Date 2008-05-01 Time 13:46 Sent To E
Notes
2008-05-01 13:53:27***FAILED***
  
  
 1)PLEASE SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE
 WITH SECTIONS 94-442 AND 94-445 OF THE CITY'S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS).
  
 2)PURSUANT TO SECTION 94-482 OF THE ZLDRS: REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS
 ARTICLE.
  
 PLEASE INDICATE DIMENSIONS AND SQUARE FOOTAGE OF ALL
 IMPERMEABLE SURFACES LOCATED WITHIN THE FRONT YARD
 (FROM FRONT PROPERTY LINE TO THE FRONT BUILDING
 FACADE).
  
 3)THE "MEAN ROOF HEIGHT FROM GRADE" AS SHOWN ON THE
 LEFT SIDE ELEVATION (SHEET A-4.0) DOES NOT MATCH THE
 OTHER ROOF HEIGHT DIMENSIONS GIVEN.PLEASE CLARIFY.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK