Plan Review Details - Permit 08040705
Plan Review Stops For Permit 08040705
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-01 Cont ID  
Sent By rmcdouga Date 2008-08-01 Time 08:52 Rev Time 0.00
Received By rmcdouga Date 2008-08-01 Time 08:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-09 Cont ID  
Sent By rmcdouga Date 2008-05-09 Time 17:21 Rev Time 0.00
Received By rmcdouga Date 2008-05-09 Time 17:21 Sent To ENG
Notes
2008-05-09 17:50:472004 FBC W/2007 REVISIONS
 LANDSCAPE AND PARKING LOT MODIFICATION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FOR A LOT WITH 83 PARKING SPACES THE REQUIRED NUMBER
 OF ACCESSIBLE PARKING SPACES IS 4 PER FBC 11-4.1.2.
  
 3) SHOW COMPLIANCE WITH 11-4.6.2 LOCATION.
 ACCESSIBLE PARKING SPACES SERVING A PARTICULAR BUILDING
 SHALL BE LOCATED ON THE SHORTEST SAFELY ACCESSIBLE
 ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE. IN PARKING FACILITIES THAT DO NOT SERVE A
 PARTICULAR BUILDING, ACCESSIBLE PARKING SHALL BE
 LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL TO
 AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE PARKING
 FACILITY. IN BUILDINGS WITH MULTIPLE ACCESSIBLE
 ENTRANCES WITH ADJACENT PARKING, ACCESSIBLE PARKING
 SPACES SHALL BE DISPERSED AND LOCATED CLOSEST TO THE
 ACCESSIBLE ENTRANCES.
  
 4) SHOW COMPLIANCE WITH 11-4.7.3 WIDTH.
 THE MINIMUM WIDTH OF A CURB RAMP SHALL BE 36 INCHES
 (915 MM), EXCLUSIVE OF FLARED SIDES.
 EXCEPTION: CURB RAMPS THAT ARE A PART OF A REQUIRED
 MEANS OF EGRESS SHALL BE NOT LESS THAN 44 INCHES (1118
 MM) WIDE.
  
 5) SHOW COMPLIANCE WITH 11-4.7.7 DETECTABLE WARNINGS.
 A CURB RAMP SHALL HAVE A DETECTABLE WARNING COMPLYING
 WITH SECTION 11-4.29.2 . THE DETECTABLE WARNING SHALL
 EXTEND THE FULL WIDTH AND DEPTH OF THE CURB RAMP.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2008-07-31 Cont ID  
Sent By rchokshi Date 2008-07-31 Time 14:02 Rev Time 0.00
Received By rchokshi Date 2008-07-31 Time 14:01 Sent To B
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2008-05-14 Cont ID  
Sent By rchokshi Date 2008-05-14 Time 09:09 Rev Time 0.00
Received By rchokshi Date 2008-05-14 Time 09:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-30 Cont ID  
Sent By adarroug Date 2008-07-30 Time 16:53 Rev Time 0.00
Received By adarroug Date 2008-07-30 Time 16:53 Sent To ENG
Notes
2008-07-30 16:53:28TO "ENG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-24 Cont ID  
Sent By adarroug Date 2008-07-24 Time 14:39 Rev Time 0.00
Received By adarroug Date 2008-07-24 Time 14:39 Sent To Z
Notes
2008-07-24 14:40:02TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-09 Cont ID  
Sent By rmcdouga Date 2008-05-09 Time 17:21 Rev Time 0.00
Received By rmcdouga Date 2008-04-28 Time 09:35 Sent To  
Notes
2008-04-28 09:35:21TO "Z" BOX

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-07-29 Cont ID  
Sent By rkussner Date 2008-07-29 Time 15:39 Rev Time 0.00
Received By rkussner Date 2008-07-29 Time 15:38 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-04-29 Cont ID  
Sent By rkussner Date 2008-04-29 Time 15:08 Rev Time 0.00
Received By rkussner Date 2008-04-29 Time 15:08 Sent To  
Notes
2008-04-29 15:45:161.THE HEDGE ALONG THE WEST PERIMETER OF THE SITE
 SHALL BE LOCATED ALONG THE INTERIOR PERIMETER OF THE
 LANDCAPE BUFFER.
  
 2.ALL AREAS THROUGHOUT THE SITE THAT ARE NOT PAVED
 OR LANDSCAPED SHALL BE SODDED.
  
 3.AN INTERIOR LANDSCAPE ISLAND AND SHADE OR
 FLOWERING TREE SHALL BE ADDED WITHIN THE PARKING ROW
 ADJACENT TO THE WEST PERIMETER OF THE SITE
 .
 4.THE ENTIRE PARKING LOT SHALL BE SHIFTED TO THE
 WEST TO ALLOW FOR A 5' LANDSCAPE PLANTING ALONG THE
 REAR FOUNDATION OF THE BUILDING OR A 5' LANDSCAPE STRIP
 BETWEEN THE PARKING ROWS IN THE CENTER OF THE REAR LOT.
 IF A LANDSCAPE STRIP IS PROVIDED ALONG THE FOUNDATION
 OF THE BUILDING, PALMS OR OTHER VERTICAL LANDSCAPE
 ELEMENTS SHALL BE INSTALLED.IF THE LANDSCAPE STRIP IS
 PROVIDED BETWEEN THE PARKING ROWS, TREES SHALL BE
 PLANTED.IN ADDITION, THE AISLES IN THE REAR LOT SHALL
 BE CHANGED FROM 25 FEET TO 24 FEET WITH THE ADDTIONAL
 AREA BEING CONVERTED INTO LANDSCAPING.
  
 5.ALL LANDCAPE AREAS SHALL BE SEPARATED FROM
 VEHICULAR USE AREAS WITH NON-MOUNTABLE REINFORCED
 CONCRETE CURBING KNOWN AS TYPE D.
  
 6.ONE TREE IS REQUIRED TO TERMINATE EACH PARKING
 ROW. TWO TREES ARE REQUIRED AT THE NORTH AND SOUTH ENDS
 OF THE CENTER PARKING ROWS (REAR LOT).
  
 7.PROVIDE A MINIMUM 5' LANDSCAPE BUFFER ALONG THE
 NORTH PERIMETER OF THE SITE. ONE TREE IS REQUIRED FOR
 EVERY 30 LINEAR FEET.
  
 8.PROVIDE A HEDGE AROUND THE DUMPSTER ENCLOSURE.
 SCREENING IS REQUIRED ON THE WEST SIDE OF THE
 TRANSFORMER.
  
 9.PROVIDE THE LOCATION OF ALL STREET LIGHTS,
 UTILITIES, EASEMENTS, OVERHANGING TREE LIMBS AND
 ANYTHING ELSE THAT MAY INTERFERE WITH THE PROPOSED
 LANDSCAPING.ON THE LANDSCAPE PLAN TO AVOID CONFLICTS
  
 10.PALMS MUST BE PLANTED IN GROUPS OF THREE.
  
 11.SHOULD THE HEDGE ALONG THE EAST PERIMETER OF THE
 SITE EVER BE REMOVED, IT SHALL BE REPLACED ALONG THE
 INTERIOR OF THE LANDSCAPE SETBACK
 .
 12.ONE SHADE OR FLOWERING TREE IS REQUIRED IN EVERY
 INTERIOR LANDSCAPE ISLAND.THAT INCLUDES BOTH TERMINAL
 ISLANDS ALONG THE PARKING ROW ALONG THE EAST PERIMETER
 OF THE SITE.
  
 13.THE TWO PARKING STALLS IN FRONT OF THE OVERHEAD
 BAY DOOR ALONG THE WEST SIDE OF THE BUILDING SHALL BE
 REMOVED AND A LANDSCAPE ISLAND SHALL BE ADDED ON BOTH
 SIDES OF THE OPENING.
  
 14.ALL EXISTING TREES AND SHRUBS TO REMAIN SHALL BE
 FLORIDA NUMBER ONE GRADE OR BETTER OR IT SHALL BE
 REPLACED.
  
 15.IF YOU ARE TAKING CREDIT FOR A MOISTURE SENSING
 CONTROLLER OTHER THAN A RAINSWITCH, PLEASE IDENTIFY
 WHAT EQUIPMENT WILL BE USED.
  
  
 ROBERT KUSSNER---(561) 822-1462

Review Stop Z ZONING
Rev No 2 Status P Date 2008-07-29 Cont ID  
Sent By adavila Date 2008-07-29 Time 17:08 Rev Time 0.00
Received By adavila Date 2008-07-29 Time 17:08 Sent To  
Notes
2008-07-29 17:09:06PROVISO HANDICAP SYMBOL SHALL BE TWO FEET FROM THE OPEN
 END OF THE PARKING SPACE.
  
 SIGNS SHALL BE APPROVED ON A SEPARATE PERMIT.
  
 PER ERIC SCHNEIDER, PRINCIPAL PLANNER.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-06 Cont ID  
Sent By adavila Date 2008-05-06 Time 14:33 Rev Time 0.00
Received By rmcdouga Date 2008-05-09 Time 17:20 Sent To B
Notes
2008-05-06 14:34:14PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. THE SITE AND LANDSCAPE PLAN APPROVED FOR THIS SITE
 SHOWS 90 PARKING SPACES IN A LAYOUT THAT DOES NOT MEET
 TODAY?S CODE.A NUMBER OF THESE SPACES WERE NOT
 MAINTAINED.THE PROPOSED SITE PLAN SHOWS A TOTAL OF 83
 PARKING SPACES.THE SITE SHALL EITHER BE RETURNED TO
 ITS ORIGINAL CONFIGURATION (90 SPACES) OR THE PARKING
 LOT MAY BE RECONFIGURED MEETING ALL CURRENT CODE
 REQUIREMENTS.THIS INCLUDES INTERIOR LANDSCAPE ISLANDS
 MEETING SECTION 94-443(C)(3)(B), ON EVERY PARKING ROW
 WITH MORE THAN 10 PARKING SPACES.PLEASE NOTE THIS
 INCLUDES SOUTH PARKING AREA AS WELL.
  
 2. PURSUANT TO SECTION 94-485(O)(1), 4 HANDICAP PARKING
 SPACES ARE REQUIRED FOR THIS SITE.AN ADDITIONAL
 HANDICAP PARKING SPACE SHALL BE PROVIDED.
  
 3. PURSUANT TO SECTION 94-443(C)(5)(A), LANDSCAPE AREAS
 SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY
 NONMOUNTABLE, CONCRETE CURBING OF THE TYPE
 CHARACTERIZED AS ?TYPE D,? OR CURBING OF COMPARABLE
 DURABILITY.PROVIDE AND IDENTIFY THE TYPE OF CURBING
 AROUND ALL TERMINAL LANDSCAPE ISLANDS AND BUFFERS.
 PLEASE NOTE THAT CURBING IS NOT REQUIRED WHERE WHEEL
 STOPS ARE LOCATED.ADDITIONALLY, PLEASE NOTE THAT THE
 CURB MAY NOT BE PART OF THE REQUIRED 5 FOOT LANDSCAPE
 ISLAND OR BUFFER.
  
 4. PURSUANT TO SECTIONS 94-443(C)(3)A AND B, EACH
 TERMINAL AND INTERIOR LANDSCAPE ISLAND SHALL CONTAIN
 ONE SHADE OR FLOWERING TREE.
  
 5. PROVIDE ACTUAL WIDTH DIMENSION OF THE TERMINAL
 LANDSCAPE ISLAND AT THE END OF THE PARKING ROW ALONG
 THE LOADING ZONE.SITE PLAN SHOWS A 10 FEET WIDTH
 DIMENSION TO A POINT OUTSIDE OF THE TERMINAL LANDSCAPE
 ISLAND.
  
 6. THE PROPOSED LOCATION FOR THE DUMPSTER ENCLOSURE HAS
 A BACK-OUT SPACE OF OVER 50 FEET, WHICH IS NOT
 PERMITTED PER THE ENGINEERING SERVICES DEPARTMENT.
 PLEASE CONTACT THE ENGINEERING SERVICES DEPARTMENT FOR
 DUMPSTER ENCLOSURE LOCATION OPTIONS.PLANNING STAFF IS
 WILLING TO MEET TO DISCUSS OPTIONS.
  
 7. PURSUANT TO SECTION 94-444(B), DUMPSTER ENCLOSURES
 SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT
 TWO-FOOT INTERVALS.
  
 8. PARKING SPACES MAY NOT BE LOCATED IN FRONT OF BAY
 DOORS.PLEASE REVIEW.
  
 9. PLEASE SEE PERMIT NO. 07120123 PLAN REVIEW COMMENTS
 REGARDING THE LOW FREE STANDING SIGN ON THE NORTHERN
 TERMINAL LANDSCAPE ISLAND OF THE SOUTH PARKING LOT.
  
 10. PLEASE NOTE THAT OUTDOOR STORAGE FACILITIES ARE NOT
 PERMITTED WITHIN THE GENERAL COMMERCIAL (GC) ZONING
 DISTRICT.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.