Plan Review Details - Permit 08040555
Plan Review Stops For Permit 08040555
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-09-13 Cont ID  
Sent By amorse Date 2008-09-13 Time 08:39 Rev Time 0.00
Received By amorse Date 2008-09-13 Time 08:39 Sent To PC
Notes
2008-09-13 08:40:17 
  
 PASSED
  
 TRUSS ENGINEERING PACKAGE

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2008-09-02 Cont ID  
Sent By amorse Date 2008-09-02 Time 15:15 Rev Time 0.00
Received By amorse Date 2008-09-02 Time 15:15 Sent To PC
Notes
2008-09-02 15:18:52DENIED
  
 1) A DESIGN PROFESSIONAL THAT IS REGISTERED TO PRACTICE
 UNDER CHAPTER 481 OR 471 OF THE FLORIDA STATUTES SHALL
 AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND DATE TO SAID
 DRAWINGS AND SPECIFICATIONS PER 106.1 FBC 2004. PHOTO
 COPIED, STAMPED OR REPRODUCED SIGNATURES ARE NOT
 ACCEPTABLE PER 471.025 F.S.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-07-19 Cont ID  
Sent By amorse Date 2008-07-19 Time 06:49 Rev Time 0.00
Received By amorse Date 2008-07-19 Time 06:49 Sent To PC
Notes
2008-07-19 06:57:50 
  
 PASSED
  
 PROVIDE LANDSCAPE PLAN TO ZONING APPROVAL BEFORE FINAL
 DATE STAMPING OF PLANS AND PERMIT ISSUANCE
  
 A RERECORDED NOTICE OF COMMENCEMENT WILL BE REQUIRED BY
 THE CONSTRUCTION SERVICES DEPT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-20 Cont ID  
Sent By amorse Date 2008-06-20 Time 14:57 Rev Time 0.00
Received By amorse Date 2008-06-20 Time 14:57 Sent To PC
Notes
2008-06-20 15:07:47 
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST
 REVIEW
  
  
 4)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE
 PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR
 SETBACKS
 ********* SEE ZONING COMMENTS, SURVEY DOES MEET SIDE
 YARD SETBACK (NOT THE SAME AS SITE PLAN USED FOR
 DRAINAGE AND LANSCAPE)*******
  
 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER
 AND OWNER/AGENT PRIOR
 TO SUBMITTAL
 *******SEE MECHANICAL COMMENTS, OVERHANG DOES NOT MEET
 REQUIREMENTS FOR THIS PRESCRIPTIVE METHOD*******
  
 13)PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES
 WITH R806.1 & 806.2 FBC RES.
  
 14)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO
 BUILDING PER 1603.1.4 FBC PLEASE NOTE THAT THE 2006
 AMENDMENTS TO THE 2004 FBC REQUIRE BUILDINGS LOCATED
 WITHIN EXP B TYPE TERRAIN THAT IS DIRECTLY ADJACENT TO
 EXP C TYPE TERRAIN SUCH AS OPEN GOLF COURSES AND BODIES
 OF WATER FOR A DISTANCE OF 600 FEET OR MORE IN ANY
 QUADRANT TO BE IN AN EXP C CATEGORY. PLEASE ADJUST THE
 DESIGN PARAMETERS AND WIND PRESSURES ACCORDINGLY
 *******THE COMPONENT AND CLADDING TABLE ON SHEET 1 WAS
 NOT CHANGED FOR EXPOSURE C, PLEASE INSERT CORRECT
 DESIGN PRESSURES. THE PRODUCT APPROVALS SUBMITTED WILL
 ALL MEET THESE INCREASED PRESSURES********
  
  
 NEW COMMENTS
  
 1)PROVIDE ORIGINAL SHEET WITH IMPACT FEE STAMP OR
 HAVE NEW DRAWINGS RE-STAMPED
  
 2)PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN
 THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING,
 THE NOTICE IS VOID
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-28 Cont ID  
Sent By amorse Date 2008-04-28 Time 17:10 Rev Time 0.00
Received By amorse Date 2008-04-28 Time 17:10 Sent To PC
Notes
2008-04-28 17:31:37 
  
 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 & 2007
 AMENDMENTS PER 106.1.1 FBC*
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $370.62 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 4)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE
 PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR
 SETBACKS
  
 5)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 7)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER
 R313.1.1 FBC RES.
  
 8)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 9)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
 10)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN
 BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN
 AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE DENIED
 ***PLEASE NOTE THAT NEW APPROVAL WILL REQUIRE
 ARCHITECTS REVIEW AND APPROVAL*****
  
 11)NO PRODUCT APPROVALS WERE SUBMITTED FOR LINTELS,
  
 12)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 13)PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES
 WITH R806.1 & 806.2 FBC RES.
  
 14)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO
 BUILDING PER 1603.1.4 FBC PLEASE NOTE THAT THE 2006
 AMENDMENTS TO THE 2004 FBC REQUIRE BUILDINGS LOCATED
 WITHIN EXP B TYPE TERRAIN THAT IS DIRECTLY ADJACENT TO
 EXP C TYPE TERRAIN SUCH AS OPEN GOLF COURSES AND BODIES
 OF WATER FOR A DISTANCE OF 600 FEET OR MORE IN ANY
 QUADRANT TO BE IN AN EXP C CATEGORY. PLEASE ADJUST THE
 DESIGN PARAMETERS AND WIND PRESSURES ACCORDINGLY
  
 15)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT
  
 16)PROVIDE DOOR AND WINDOW TYPES AND SIZES ON THE
 DRAWINGS
  
 17)THE PRODUCT APPROVALS FOR EXTERIOR DOORS HAS AN
 INVALID STATEWIDE APPROVAL NUMBER, THE MIAMI-DADE
 REPORT SUBMITTED IS UNDER FL # 253-R7
  
 18)THE STATEWIDE PRODUCT APPROVAL FOR ASPHALT
 SHINGLES HAS A UL COMPLIANCE REPORT AND INSTALLATION
 INSTRUCTIONS NOT THE MIAMI-DADE NOA THAT WAS SUBMITTED
 WITH IT, ALSO THE MIAMI-DADE NOA HAS EXPIRED.
  
 19)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER
 R803.2.3.1 FBC RES. MIN 8D RING SHANK NAILS
  
 20)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS
 REQUIRED PER R807.1 FBC RES.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-06-10 Cont ID  
Sent By btrobaug Date 2008-06-10 Time 12:04 Rev Time 0.00
Received By btrobaug Date 2008-06-10 Time 11:36 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-22 Cont ID  
Sent By btrobaug Date 2008-04-22 Time 15:18 Rev Time 0.00
Received By btrobaug Date 2008-04-22 Time 14:34 Sent To Z
Notes
2008-04-22 15:17:44 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS
 AMENDED, CHAPTER 1ARE THE GOVERNING CODES INDICATE SAME
 ON THE PLANS. 106.1.3 FBC AS AMENDED.
  
 ALL COMMENTS RELATE TO SHEET 2 OF 4, UNLESS OTHERWISE
 NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS
 OTHERWISE NOTED.
  
 1} PROVIDE LOAD CALCULATIONS FOR THE ENTIRE SERVICE
 INCLUDING THE ADDITION PER ARTICLE 220 PART III,
 STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED.
  
 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} PLEASE PROVIDE A PANEL SCHEDULE SO THAT
 BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT
 PROTECTION COMPLIANCE MAY BE REVIEWED PER 408.4 NEC,
 106.3.5.4 FBC AS AMENDED.
  
 4} THE NOTE ON THE RISER AND ON THE BOTTOM LEFT OF THE
 SHEET ARE CONTRADICTORY. 200 AMPS ON THE RISER AND 150
 AMPS IN THE NOTE. VERIFY SERVICE RATING AND INCLUDE
 THAT INFORMATION WITH THE PANEL SCHEDULE AND RISER
 DIAGRAM.
  
 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN
 INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS
 SHALL BE INTERCONNECTED AND HARD WIRED. LOCATE ALARMS
 ON THE PLAN.
  
 6} THERE IS A SPA ON THE PLAN BUT NOT ON THE PANEL
 SCHEDULE, NO GFI IS SHOWN ON THE SCHEDULE PER 680.43,
 OR ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-09-10 Cont ID  
Sent By adarroug Date 2008-09-10 Time 11:19 Rev Time 0.00
Received By adarroug Date 2008-09-10 Time 11:19 Sent To B
Notes
2008-09-10 11:19:19TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-09-02 Cont ID  
Sent By adarroug Date 2008-09-02 Time 11:02 Rev Time 0.00
Received By adarroug Date 2008-09-02 Time 11:02 Sent To B
Notes
2008-09-02 11:03:03TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-07-22 Cont ID  
Sent By adarroug Date 2008-07-22 Time 10:30 Rev Time 0.00
Received By adarroug Date 2008-07-22 Time 10:30 Sent To Z
Notes
2008-07-22 10:30:32TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-07-18 Cont ID  
Sent By adarroug Date 2008-07-18 Time 13:42 Rev Time 0.00
Received By adarroug Date 2008-07-18 Time 13:42 Sent To M
Notes
2008-07-18 13:43:32TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-14 Cont ID  
Sent By adarroug Date 2008-07-14 Time 08:49 Rev Time 0.00
Received By adarroug Date 2008-07-14 Time 08:49 Sent To Z
Notes
2008-07-14 08:50:25TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-04 Cont ID  
Sent By adarroug Date 2008-06-04 Time 16:25 Rev Time 0.00
Received By adarroug Date 2008-06-04 Time 16:25 Sent To Z
Notes
2008-06-04 16:26:05TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-04-28 Time   Rev Time 0.00
Received By adarroug Date 2008-04-22 Time 09:13 Sent To  
Notes
2008-04-22 09:13:57TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-07-29 Cont ID  
Sent By kdfreema Date 2008-07-29 Time 11:22 Rev Time 0.00
Received By kdfreema Date 2008-07-29 Time 11:22 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-07-16 Cont ID  
Sent By rkussner Date 2008-07-16 Time 15:15 Rev Time 0.00
Received By rkussner Date 2008-07-17 Time 08:56 Sent To  
Notes
2008-07-16 15:41:03PROVIDE A PLANT LIST ON THE LANDSCAPE PLAN.IT SHALL
 INCLUDE THE PLANT NAME, QUANTITY, SIZE AND SPACING OF
 ALL PROPOSED PLANT MATERIAL. PLAN SHOULD BE DRAWN AT A
 LARGER SCALE SUCH AS 1"=10' OR 1" = 8'.
  
 PROVIDE LANDSCAPE CALCULATIONS (REQUIRED AND PROPOSED)
 BASED UPON SECTION 94-441 OF THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 IDENTIFY ALL EXISTING PLANT MATERIAL.
  
 SHOW ALL UTILITIES ON LANDSCAPE PLAN TO AVOID
 CONFLICTS.
  
 SHOW ALL TREES ON NEIGHBORING PROPERTY THAT ARE IN
 CLOSE PROXIMITY TO THE PROPERTY LINE THAT HAVE THE
 CAPACITY OF GROWING OVER THE PROPERTY LINE.
  
 PROVIDE SOD AND IRRIGATION IN THE RIGHT OF WAY.
  
 PROVIDE THE QUANTITY OF PLANTS PROPOSED TO BE PLANTED
 IN EACH PLANT BED.
  
 PROVIDE A PLANTING DETAIL.
  
 ALL EXISTING AND PROPOSED TREES AND SHRUBS SHALL BE
 FLORIDA NUMBER 1 GRADE OR BETTER.IF ANY EXISTING
 TREES, SHRUBS AND GROUND COVER DO NOT MEET THIS
 REQUIREMENT, THEN THEY MUST BE REPLACED.
  
 PROVIDE SCREENING FOR ALL MECHANICAL EQUIPMENT AND
 TRASH CONTAINERS.
  
  
  
 PLEASE CONTACT ROBERT KUSSNER AT (561) 822-1462 IF YOU
 HAVE ANY QUESTIONS REGARDING THE LANDSCAPE COMMENTS.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2008-07-18 Cont ID  
Sent By tgordon Date 2008-07-18 Time 14:46 Rev Time 0.25
Received By tgordon Date 2008-07-18 Time 14:46 Sent To B
Notes
2008-07-18 14:48:05NOTICE: A MECHANICAL (A/C) PERMIT WILL BE REQUIRED FOR
 THE BATHROOM EXHAUST FAN.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-06-10 Cont ID  
Sent By tgordon Date 2008-06-10 Time 14:10 Rev Time 0.30
Received By tgordon Date 2008-06-10 Time 14:10 Sent To P
Notes
2008-06-10 14:23:21PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS LINE 7 IS SHOWING THE EAVE
 OVERHANG AS 1 FT. 6 IN. PER TABLE 6B-1 ON BACK OF THE
 ENERGY CALCULATIONS SUBMITTED THE REQUIRED OVERHANG IS
 2 FT. PLEASE REVISE THE ENERGY CALCULATIONS AND PLANS
 OR USE FORM A OR C FOR THE ENERGY CAL,S. PER 2004 FBC
 13-601.1.B.3 AND 13-103.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-04-23 Cont ID  
Sent By tgordon Date 2008-04-23 Time 14:39 Rev Time 0.25
Received By tgordon Date 2008-04-23 Time 14:39 Sent To P
Notes
2008-04-23 14:43:29PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC
 13-101.2.2.
  
 2) IF ANY MECHANICAL (A/C) WORK IS TO BE DONE, SUBMIT
 MECHANICAL PLANS AT THIS TIME, PER WPB AMEND. 106.3.5.4
 (10).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-06-10 Cont ID  
Sent By mperson Date 2008-06-10 Time 14:46 Rev Time 0.00
Received By mperson Date 2008-06-10 Time 14:46 Sent To B
Notes
2008-06-10 14:47:25******PROVISO******
 PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN THE
 INSTALLATION OR REMOVAL OF ANY PART OF A DRAINAGE
 SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING
 PERMIT IS REQUIRED AND AN INSPECTION IS REQUIRED OF
 PLUMBING DEMO WORK PRIOR TO COVERING DEMO WORK WITH
 FINNISH WALLS, CIELINGS, OR POURED CONCRETE SLABS.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-24 Cont ID  
Sent By mperson Date 2008-04-24 Time 15:48 Rev Time 0.00
Received By mperson Date 2008-04-24 Time 15:48 Sent To B
Notes
2008-04-24 16:13:28PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET 2 SANITARY ISOMETRIC RISER DIAGRAM PLEASE
 CORRECT THE FOLLOWING:
 A} ISOMETRIC DOES NOT REFLECT THE FLOOR PLAN. THE TWO
 LAVATORIES IN THE MASTER BATHROOM ARE MISSING FROM THE
 RISER DIAGRAM. PLEASE CORRECT THIS ON THE RESUBMITTAL.
 PER FBC PLUMBING SECTION 701.1 SCOPE.
  
 B} THE HORIZONTAL DRY VENT FOR THE TUB AND SHOWER IS
 NOT COMPLIANT. PER FBC PLUMBING SECTION 905.3 VENT
 CONNECTION TO THE DRAINAGE SYSTEM.
  
 C} CLEARLY INDICATE A TWO-WAY CLEANOUT AT THE JUNCTION
 OF THE BUILDING DRAIN AND BUILDING SEWER. PER FBC
 PLUMBING SECTION 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION.
  
 2. SHEET 2 PLEASE CLARIFY IF THE BATHROOM AT THE
 FAMILY ROOM AND PLAY ROOM IS EXISTING OR NEW. PER
 (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. IF THIS IS A NEW BATHROOM A
 SANITARY ISOMETRIC RISER DIAGRAM WILL BE REQUIRED. PER
 (W.P.B. AS AMENDED SECTION 106.3.5.4 RESIDENTIAL (9)
 PLUMBING.
  
 3. SHEET 2 THE FOLLOWING IS INDICATED "NOTE: ALL
 EXISTING PLUMBING IN MASTER BEDROOM WATER LINE AND
 DRAIN LINE TO BE CAP OFF". PLEASE PROVIDE AN EXISTING
 FLOOR PLAN LAYOUT AND CLEARLY INDICATE WHAT IS BEING
 DEMOED. PER (W.P.B. AS AMENDED) SECTION 106.1.2
 ADDITIONAL DATA. PLEASE ADD THE FOLLOWING TO THE DEMO
 PLAN PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN
 THE INSTALLATION OR REMOVAL OF ANY PART OF A DRAINAGE
 SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING
 PERMIT REQUIRED AND INSPECTION REQUIRED OF DEMO WORK
 PRIOR TO COVERING DEMO WORK WITH FINNISH WALLS,
 CIELINGS, OR POURED CONCRETE SLABS.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2008-07-28 Cont ID  
Sent By kdfreema Date 2008-07-28 Time 09:08 Rev Time 0.00
Received By kdfreema Date 2008-07-28 Time 09:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2008-07-17 Cont ID  
Sent By kdfreema Date 2008-07-17 Time 08:14 Rev Time 0.00
Received By kdfreema Date 2008-07-17 Time 08:14 Sent To  
Notes
2008-07-17 08:16:30***FAILED***
  
 SETBACK ISSUE HAS BEEN RESOLVED, HOWEVER, THE SUBMITTED
 LANDSCAPE PLAN DOES NOT COMPLY WITH THE CITY'S MINIMUM
 REQUIREMENTS. PLEASE SEE LANDSCAPE COMMENTS FOR FURTHER
 INFORMATION.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435
 WITH QUESTIONS.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-06-09 Cont ID  
Sent By choops Date 2008-06-09 Time 14:16 Rev Time 0.00
Received By choops Date 2008-06-09 Time 14:16 Sent To E
Notes
2008-06-09 14:17:01***FAILED - RESUB #1***
  
  
 REPEAT COMMENTS:
  
 1)NEW CONSTRUCTION MUST MEET MINIMUM REQUIRED
 SETBACKS AS LISTED IN SECTION 94-72 OF THE CITY'S
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS):
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING.
 A.FRONT: 25 FEET;
 B.CORNER SIDE, IF APPLICABLE: 12.5 FEET;
 C.REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH,
 WHICHEVER IS LESS;
 D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 THE ADDITION, AS SHOWN ON THE SUBMITTED SURVEYS, DOES
 NOT MEET THE MINIMUM REQUIRED 5 FOOT SIDE SETBACK.
 PLEASE REVISE.
  
 4)PURSUANT TO SECTION 94-441(C)(2) OF THE ZLDRS: AS
 THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE
 STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH
 THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING
 SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS
 FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE SUBMIT A
 LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442
 AND 94-445 OF THE ZLDRS.
  
 THE SUBMITTED LANDSCAPE PLAN DOES NOT SHOW COMPLIANCE
 WITH CITED CODE SECTIONS AND DOES NOT CONTAIN THE
 NECESSARY INFORMATION.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2008-04-23 Cont ID  
Sent By choops Date 2008-04-23 Time 10:44 Rev Time 0.00
Received By choops Date 2008-04-23 Time 10:44 Sent To M
Notes
2008-04-23 10:56:48***FAILED***
  
  
 1)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED
 ADDITION TO ALL PROPERTY LINES ON EITHER A SITE PLAN OR
 THE SURVEYS.
  
 NOTE:NEW CONSTRUCTION MUST MEET MINIMUM REQUIRED
 SETBACKS AS LISTED IN SECTION 94-72 OF THE CITY'S
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS):
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING.
 A.FRONT: 25 FEET;
 B.CORNER: 12.5 FEET;
 C.REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH,
 WHICHEVER IS LESS;
 D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 2)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 3)INDICATE OVERHANG DIMENSIONS OF THE PROPOSED
 ADDITION.NOTE:PURSUANT TO SECTION 94-305 OF THE
 ZLDRS: OVERHANGS MAY NOT PROJECT MORE THAN 3 FEET INTO
 A REQUIRED SETBACK.
  
 4)PURSUANT TO SECTION 94-441(C)(2) OF THE ZLDRS: AS
 THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE
 STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH
 THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING
 SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS
 FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE SUBMIT A
 LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442
 AND 94-445 OF THE ZLDRS.
  
 5)INDICATE THE HEIGHT OF THE PROPOSED ADDITION FROM
 GRADE TO THE MIDPOINT OF THE ROOF'S PITCH.
  
  
 NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - SF RACK