Plan Review Stops For Permit 08040555 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-09-13 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-09-13 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-09-13 |
Time |
08:39 |
Sent To |
PC |
|
Notes |
2008-09-13 08:40:17 | | | | | PASSED | | | | TRUSS ENGINEERING PACKAGE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-09-02 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-09-02 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-09-02 |
Time |
15:15 |
Sent To |
PC |
|
Notes |
2008-09-02 15:18:52 | DENIED | | | | 1) A DESIGN PROFESSIONAL THAT IS REGISTERED TO PRACTICE | | UNDER CHAPTER 481 OR 471 OF THE FLORIDA STATUTES SHALL | | AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND DATE TO SAID | | DRAWINGS AND SPECIFICATIONS PER 106.1 FBC 2004. PHOTO | | COPIED, STAMPED OR REPRODUCED SIGNATURES ARE NOT | | ACCEPTABLE PER 471.025 F.S. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-07-19 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-07-19 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-07-19 |
Time |
06:49 |
Sent To |
PC |
|
Notes |
2008-07-19 06:57:50 | | | | | PASSED | | | | PROVIDE LANDSCAPE PLAN TO ZONING APPROVAL BEFORE FINAL | | DATE STAMPING OF PLANS AND PERMIT ISSUANCE | | | | A RERECORDED NOTICE OF COMMENCEMENT WILL BE REQUIRED BY | | THE CONSTRUCTION SERVICES DEPT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-06-20 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-06-20 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-06-20 |
Time |
14:57 |
Sent To |
PC |
|
Notes |
2008-06-20 15:07:47 | | | | | DENIED | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST | | REVIEW | | | | | | 4)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE | | PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR | | SETBACKS | | ********* SEE ZONING COMMENTS, SURVEY DOES MEET SIDE | | YARD SETBACK (NOT THE SAME AS SITE PLAN USED FOR | | DRAINAGE AND LANSCAPE)******* | | | | 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | AND OWNER/AGENT PRIOR | | TO SUBMITTAL | | *******SEE MECHANICAL COMMENTS, OVERHANG DOES NOT MEET | | REQUIREMENTS FOR THIS PRESCRIPTIVE METHOD******* | | | | 13)PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES | | WITH R806.1 & 806.2 FBC RES. | | | | 14)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO | | BUILDING PER 1603.1.4 FBC PLEASE NOTE THAT THE 2006 | | AMENDMENTS TO THE 2004 FBC REQUIRE BUILDINGS LOCATED | | WITHIN EXP B TYPE TERRAIN THAT IS DIRECTLY ADJACENT TO | | EXP C TYPE TERRAIN SUCH AS OPEN GOLF COURSES AND BODIES | | OF WATER FOR A DISTANCE OF 600 FEET OR MORE IN ANY | | QUADRANT TO BE IN AN EXP C CATEGORY. PLEASE ADJUST THE | | DESIGN PARAMETERS AND WIND PRESSURES ACCORDINGLY | | *******THE COMPONENT AND CLADDING TABLE ON SHEET 1 WAS | | NOT CHANGED FOR EXPOSURE C, PLEASE INSERT CORRECT | | DESIGN PRESSURES. THE PRODUCT APPROVALS SUBMITTED WILL | | ALL MEET THESE INCREASED PRESSURES******** | | | | | | NEW COMMENTS | | | | 1)PROVIDE ORIGINAL SHEET WITH IMPACT FEE STAMP OR | | HAVE NEW DRAWINGS RE-STAMPED | | | | 2)PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN | | THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING, | | THE NOTICE IS VOID | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-04-28 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-04-28 |
Time |
17:10 |
Sent To |
PC |
|
Notes |
2008-04-28 17:31:37 | | | | | DENIED | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 & 2007 | | AMENDMENTS PER 106.1.1 FBC* | | | | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC* | | | | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $370.62 FOR | | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS | | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW | | | | 4)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE | | PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR | | SETBACKS | | | | 5)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN | | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES. | | | | 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | TO SUBMITTAL | | | | 7)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. | | | | 8)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | 9)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | 10)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL SHEETS WHEN AVAILABLE. THEY CAN | | BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.WHEN | | AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE DENIED | | ***PLEASE NOTE THAT NEW APPROVAL WILL REQUIRE | | ARCHITECTS REVIEW AND APPROVAL***** | | | | 11)NO PRODUCT APPROVALS WERE SUBMITTED FOR LINTELS, | | | | 12)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD | | | | 13)PROVIDE ROOF VENTILATION ON DRAWINGS THAT COMPLIES | | WITH R806.1 & 806.2 FBC RES. | | | | 14)PROVIDE THE WIND DESIGN DATA THAT APPLIES TO | | BUILDING PER 1603.1.4 FBC PLEASE NOTE THAT THE 2006 | | AMENDMENTS TO THE 2004 FBC REQUIRE BUILDINGS LOCATED | | WITHIN EXP B TYPE TERRAIN THAT IS DIRECTLY ADJACENT TO | | EXP C TYPE TERRAIN SUCH AS OPEN GOLF COURSES AND BODIES | | OF WATER FOR A DISTANCE OF 600 FEET OR MORE IN ANY | | QUADRANT TO BE IN AN EXP C CATEGORY. PLEASE ADJUST THE | | DESIGN PARAMETERS AND WIND PRESSURES ACCORDINGLY | | | | 15)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT | | | | 16)PROVIDE DOOR AND WINDOW TYPES AND SIZES ON THE | | DRAWINGS | | | | 17)THE PRODUCT APPROVALS FOR EXTERIOR DOORS HAS AN | | INVALID STATEWIDE APPROVAL NUMBER, THE MIAMI-DADE | | REPORT SUBMITTED IS UNDER FL # 253-R7 | | | | 18)THE STATEWIDE PRODUCT APPROVAL FOR ASPHALT | | SHINGLES HAS A UL COMPLIANCE REPORT AND INSTALLATION | | INSTRUCTIONS NOT THE MIAMI-DADE NOA THAT WAS SUBMITTED | | WITH IT, ALSO THE MIAMI-DADE NOA HAS EXPIRED. | | | | 19)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER | | R803.2.3.1 FBC RES. MIN 8D RING SHANK NAILS | | | | 20)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS | | REQUIRED PER R807.1 FBC RES. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-06-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-06-10 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-06-10 |
Time |
11:36 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-22 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-22 |
Time |
14:34 |
Sent To |
Z |
|
Notes |
2008-04-22 15:17:44 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | AMENDED, CHAPTER 1ARE THE GOVERNING CODES INDICATE SAME | | ON THE PLANS. 106.1.3 FBC AS AMENDED. | | | | ALL COMMENTS RELATE TO SHEET 2 OF 4, UNLESS OTHERWISE | | NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | OTHERWISE NOTED. | | | | 1} PROVIDE LOAD CALCULATIONS FOR THE ENTIRE SERVICE | | INCLUDING THE ADDITION PER ARTICLE 220 PART III, | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. | | | | 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | 3} PLEASE PROVIDE A PANEL SCHEDULE SO THAT | | BRANCH/FEEDER CIRCUIT CONDUCTOR AND OVER CURRENT | | PROTECTION COMPLIANCE MAY BE REVIEWED PER 408.4 NEC, | | 106.3.5.4 FBC AS AMENDED. | | | | 4} THE NOTE ON THE RISER AND ON THE BOTTOM LEFT OF THE | | SHEET ARE CONTRADICTORY. 200 AMPS ON THE RISER AND 150 | | AMPS IN THE NOTE. VERIFY SERVICE RATING AND INCLUDE | | THAT INFORMATION WITH THE PANEL SCHEDULE AND RISER | | DIAGRAM. | | | | 5} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS | | SHALL BE INTERCONNECTED AND HARD WIRED. LOCATE ALARMS | | ON THE PLAN. | | | | 6} THERE IS A SPA ON THE PLAN BUT NOT ON THE PANEL | | SCHEDULE, NO GFI IS SHOWN ON THE SCHEDULE PER 680.43, | | OR ON THE PLAN. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2008-09-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-10 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-10 |
Time |
11:19 |
Sent To |
B |
|
Notes |
2008-09-10 11:19:19 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-09-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-02 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-02 |
Time |
11:02 |
Sent To |
B |
|
Notes |
2008-09-02 11:03:03 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-22 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-22 |
Time |
10:30 |
Sent To |
Z |
|
Notes |
2008-07-22 10:30:32 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-18 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-18 |
Time |
13:42 |
Sent To |
M |
|
Notes |
2008-07-18 13:43:32 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-14 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-14 |
Time |
08:49 |
Sent To |
Z |
|
Notes |
2008-07-14 08:50:25 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-04 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-04 |
Time |
16:25 |
Sent To |
Z |
|
Notes |
2008-06-04 16:26:05 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2008-04-28 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-22 |
Time |
09:13 |
Sent To |
|
|
Notes |
2008-04-22 09:13:57 | TO "SFR" "Z" |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-07-29 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-07-29 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2008-07-16 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-07-16 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-07-17 |
Time |
08:56 |
Sent To |
|
|
Notes |
2008-07-16 15:41:03 | PROVIDE A PLANT LIST ON THE LANDSCAPE PLAN.IT SHALL | | INCLUDE THE PLANT NAME, QUANTITY, SIZE AND SPACING OF | | ALL PROPOSED PLANT MATERIAL. PLAN SHOULD BE DRAWN AT A | | LARGER SCALE SUCH AS 1"=10' OR 1" = 8'. | | | | PROVIDE LANDSCAPE CALCULATIONS (REQUIRED AND PROPOSED) | | BASED UPON SECTION 94-441 OF THE CITY OF WEST PALM | | BEACH ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | IDENTIFY ALL EXISTING PLANT MATERIAL. | | | | SHOW ALL UTILITIES ON LANDSCAPE PLAN TO AVOID | | CONFLICTS. | | | | SHOW ALL TREES ON NEIGHBORING PROPERTY THAT ARE IN | | CLOSE PROXIMITY TO THE PROPERTY LINE THAT HAVE THE | | CAPACITY OF GROWING OVER THE PROPERTY LINE. | | | | PROVIDE SOD AND IRRIGATION IN THE RIGHT OF WAY. | | | | PROVIDE THE QUANTITY OF PLANTS PROPOSED TO BE PLANTED | | IN EACH PLANT BED. | | | | PROVIDE A PLANTING DETAIL. | | | | ALL EXISTING AND PROPOSED TREES AND SHRUBS SHALL BE | | FLORIDA NUMBER 1 GRADE OR BETTER.IF ANY EXISTING | | TREES, SHRUBS AND GROUND COVER DO NOT MEET THIS | | REQUIREMENT, THEN THEY MUST BE REPLACED. | | | | PROVIDE SCREENING FOR ALL MECHANICAL EQUIPMENT AND | | TRASH CONTAINERS. | | | | | | | | PLEASE CONTACT ROBERT KUSSNER AT (561) 822-1462 IF YOU | | HAVE ANY QUESTIONS REGARDING THE LANDSCAPE COMMENTS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2008-07-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-07-18 |
Time |
14:46 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-07-18 |
Time |
14:46 |
Sent To |
B |
|
Notes |
2008-07-18 14:48:05 | NOTICE: A MECHANICAL (A/C) PERMIT WILL BE REQUIRED FOR | | THE BATHROOM EXHAUST FAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-06-10 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-06-10 |
Time |
14:10 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-06-10 |
Time |
14:10 |
Sent To |
P |
|
Notes |
2008-06-10 14:23:21 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS LINE 7 IS SHOWING THE EAVE | | OVERHANG AS 1 FT. 6 IN. PER TABLE 6B-1 ON BACK OF THE | | ENERGY CALCULATIONS SUBMITTED THE REQUIRED OVERHANG IS | | 2 FT. PLEASE REVISE THE ENERGY CALCULATIONS AND PLANS | | OR USE FORM A OR C FOR THE ENERGY CAL,S. PER 2004 FBC | | 13-601.1.B.3 AND 13-103.3. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-23 |
Time |
14:39 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-04-23 |
Time |
14:39 |
Sent To |
P |
|
Notes |
2008-04-23 14:43:29 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | 13-101.2.2. | | | | 2) IF ANY MECHANICAL (A/C) WORK IS TO BE DONE, SUBMIT | | MECHANICAL PLANS AT THIS TIME, PER WPB AMEND. 106.3.5.4 | | (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-06-10 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-06-10 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-06-10 |
Time |
14:46 |
Sent To |
B |
|
Notes |
2008-06-10 14:47:25 | ******PROVISO****** | | PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN THE | | INSTALLATION OR REMOVAL OF ANY PART OF A DRAINAGE | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING | | PERMIT IS REQUIRED AND AN INSPECTION IS REQUIRED OF | | PLUMBING DEMO WORK PRIOR TO COVERING DEMO WORK WITH | | FINNISH WALLS, CIELINGS, OR POURED CONCRETE SLABS. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-04-24 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-04-24 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-04-24 |
Time |
15:48 |
Sent To |
B |
|
Notes |
2008-04-24 16:13:28 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET 2 SANITARY ISOMETRIC RISER DIAGRAM PLEASE | | CORRECT THE FOLLOWING: | | A} ISOMETRIC DOES NOT REFLECT THE FLOOR PLAN. THE TWO | | LAVATORIES IN THE MASTER BATHROOM ARE MISSING FROM THE | | RISER DIAGRAM. PLEASE CORRECT THIS ON THE RESUBMITTAL. | | PER FBC PLUMBING SECTION 701.1 SCOPE. | | | | B} THE HORIZONTAL DRY VENT FOR THE TUB AND SHOWER IS | | NOT COMPLIANT. PER FBC PLUMBING SECTION 905.3 VENT | | CONNECTION TO THE DRAINAGE SYSTEM. | | | | C} CLEARLY INDICATE A TWO-WAY CLEANOUT AT THE JUNCTION | | OF THE BUILDING DRAIN AND BUILDING SEWER. PER FBC | | PLUMBING SECTION 708.3.5 BUILDING DRAIN AND BUILDING | | SEWER JUNCTION. | | | | 2. SHEET 2 PLEASE CLARIFY IF THE BATHROOM AT THE | | FAMILY ROOM AND PLAY ROOM IS EXISTING OR NEW. PER | | (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. IF THIS IS A NEW BATHROOM A | | SANITARY ISOMETRIC RISER DIAGRAM WILL BE REQUIRED. PER | | (W.P.B. AS AMENDED SECTION 106.3.5.4 RESIDENTIAL (9) | | PLUMBING. | | | | 3. SHEET 2 THE FOLLOWING IS INDICATED "NOTE: ALL | | EXISTING PLUMBING IN MASTER BEDROOM WATER LINE AND | | DRAIN LINE TO BE CAP OFF". PLEASE PROVIDE AN EXISTING | | FLOOR PLAN LAYOUT AND CLEARLY INDICATE WHAT IS BEING | | DEMOED. PER (W.P.B. AS AMENDED) SECTION 106.1.2 | | ADDITIONAL DATA. PLEASE ADD THE FOLLOWING TO THE DEMO | | PLAN PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS: IN | | THE INSTALLATION OR REMOVAL OF ANY PART OF A DRAINAGE | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A PLUMBING | | PERMIT REQUIRED AND INSPECTION REQUIRED OF DEMO WORK | | PRIOR TO COVERING DEMO WORK WITH FINNISH WALLS, | | CIELINGS, OR POURED CONCRETE SLABS. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-07-28 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-07-28 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2008-07-17 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2008-07-17 |
Time |
08:14 |
Sent To |
|
|
Notes |
2008-07-17 08:16:30 | ***FAILED*** | | | | SETBACK ISSUE HAS BEEN RESOLVED, HOWEVER, THE SUBMITTED | | LANDSCAPE PLAN DOES NOT COMPLY WITH THE CITY'S MINIMUM | | REQUIREMENTS. PLEASE SEE LANDSCAPE COMMENTS FOR FURTHER | | INFORMATION. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | WITH QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-06-09 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-06-09 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-06-09 |
Time |
14:16 |
Sent To |
E |
|
Notes |
2008-06-09 14:17:01 | ***FAILED - RESUB #1*** | | | | | | REPEAT COMMENTS: | | | | 1)NEW CONSTRUCTION MUST MEET MINIMUM REQUIRED | | SETBACKS AS LISTED IN SECTION 94-72 OF THE CITY'S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS): | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | A.FRONT: 25 FEET; | | B.CORNER SIDE, IF APPLICABLE: 12.5 FEET; | | C.REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, | | WHICHEVER IS LESS; | | D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | THE ADDITION, AS SHOWN ON THE SUBMITTED SURVEYS, DOES | | NOT MEET THE MINIMUM REQUIRED 5 FOOT SIDE SETBACK. | | PLEASE REVISE. | | | | 4)PURSUANT TO SECTION 94-441(C)(2) OF THE ZLDRS: AS | | THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING | | SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS | | FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE SUBMIT A | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442 | | AND 94-445 OF THE ZLDRS. | | | | THE SUBMITTED LANDSCAPE PLAN DOES NOT SHOW COMPLIANCE | | WITH CITED CODE SECTIONS AND DOES NOT CONTAIN THE | | NECESSARY INFORMATION. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-04-23 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-04-23 |
Time |
10:44 |
Sent To |
M |
|
Notes |
2008-04-23 10:56:48 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED | | ADDITION TO ALL PROPERTY LINES ON EITHER A SITE PLAN OR | | THE SURVEYS. | | | | NOTE:NEW CONSTRUCTION MUST MEET MINIMUM REQUIRED | | SETBACKS AS LISTED IN SECTION 94-72 OF THE CITY'S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS): | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | A.FRONT: 25 FEET; | | B.CORNER: 12.5 FEET; | | C.REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, | | WHICHEVER IS LESS; | | D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | 2)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 3)INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | ADDITION.NOTE:PURSUANT TO SECTION 94-305 OF THE | | ZLDRS: OVERHANGS MAY NOT PROJECT MORE THAN 3 FEET INTO | | A REQUIRED SETBACK. | | | | 4)PURSUANT TO SECTION 94-441(C)(2) OF THE ZLDRS: AS | | THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING | | SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS | | FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE SUBMIT A | | LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTIONS 94-442 | | AND 94-445 OF THE ZLDRS. | | | | 5)INDICATE THE HEIGHT OF THE PROPOSED ADDITION FROM | | GRADE TO THE MIDPOINT OF THE ROOF'S PITCH. | | | | | | NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "M" - SF RACK |
|
|