Plan Review Stops For Permit 08040313 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-09-30 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-09-30 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-22 |
Time |
07:04 |
Sent To |
|
|
Notes |
2008-04-22 08:44:43 | 2004 FBC W/2007 REVISIONS | | CHANGE OF OCCUPANCY | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | BE REQUIRED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. PHONE (561) | | 233-5025 | | | | 3) THE DECLARED VALUE OF THE WORK IS TOO LOW. THE VALUE | | IS REQUIRED TO REFLECT THE COSTS OF LABOR, MATERIALS, | | OVERHEAD AND PROFIT THAT WOULD BE REQUIRED TO CONVERT | | THE GARAGE TO AN OFFICE. INCLUDING ALL OF THE | | UN-PERMITTED WORK. PLEASE REVISE. FBC 108.3* CITY | | AMENDMENTS. | | | | 4) SUBMIT TWO COPIES OF ENERGY CALCULATION FORMS AS | | REQUIRED BY FBC 13-600. THE OWNER/AGENT IS REQUIRED TO | | SIGN THE FORMS. | | | | 5) SPECIFY THE INSULATION R-VALUES FOR THE WALL AND | | CEILING INSULATION. SEE FBC 13-600. | | | | 6) THE CONSTRUCTION TYPE SPECIFIED ON SHEET SP-1 IS | | INCOMPLETE. SPECIFY CONSTRUCTION TYPE VA FOR ONE HOUR | | PROTECTED OR TYPE VB FOR UNPROTECTED. SEE FBC TABLE | | 601. | | | | 7) THE DOOR TO BATHROOM IS REQUIRED TO HAVE A 29" CLEAR | | OPENING PER FBC EXISTING BUILDING SECTION 812.5 AND FBC | | 11-4.22.2. | | | | 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EACH TYPE | | OF EXTERIOR DOOR AND STORM PANELS. SPECIFY THE MOUNT | | TYPE, FASTENER TYPE AND SPACING, EDGE DISTANCE, SPANS, | | ETC. FOR THE STORM PANELS. | | | | 9) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 10) THE CLASSIFICATION OF WORK ON SHEET SP-1 IS | | INCORRECT. THIS IS CONSIDERED A CHANGE OF OCCUPANCY NOT | | A LEVEL 2 ALTERATION. SEE 2004 FBC EXISTING BUILDING | | CHAPTER 3. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-09-25 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-09-25 |
Time |
06:37 |
Sent To |
M |
|
Notes |
2008-09-25 08:05:34 | | | | | PROVISO | | | | THE CONDENSING UNIT MUST BE A MINIMUM OF 3' FROM THE | | SERVICE. 110.26 NEC | | | | A RECEPTACLE PER 210.63 IS REQUIRED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-15 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-15 |
Time |
10:45 |
Sent To |
Z |
|
Notes |
2008-04-15 11:34:45 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | FOLLOWING: | | | | 1}INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE | | PLAN IS NEW OR EXISTING. IF NEW INCLUDE IN THE | | DESCRIPTION ON THE APPLICATION, PROVIDE AN AIC RATING | | PER 110.9 AND 110.10. | | | | 2} CIRCUIT #7 BATH LIGHT AND RECEPTACLE HAS AN OCP OF | | 30 AMPS WITH A #12 CONDUCTOR IN VIOLATION OF 310.16. | | THIS CIRCUIT IS REQUIRED TO BE 20 AMP PER | | 210.11(C)(3). | | | | 3} THERE IS A HOT TUB ON THE PANEL SCHEDULE THAT IS NOT | | LOCATED ON THE PLAN. SHEET A-1 INDICATES A SHOWER IN | | THE BATHROOM. SEE 680.43(A)(2) FOR GFCI REQUIREMENTS. | | | | 4} THE "MAIN HOUSE SUB PANEL" IS LISTED AT 100 AMPS IN | | PANEL "A", BUT SHOWN AS 110 AMPS ON THE RISER | | | | 5} THERE IS NO REFRIGERATOR LISTED IN THE LOAD | | CALCULATIONS, YET ONE IS LISTED IN THE PANEL SCHEDULE | | AND SHOWN ON THE PLAN CONFIRM THAT THERE IS NO OTHER | | APPLIANCES THAT ARE REQUIRED TO BE IN THE LOAD | | CALCULATIONS. CONFIRM THE WATER HEATER IS IN THE MAIN | | HOUSE AND THERE IS NONE IN THE ACCESSORY BUILDING. | | | | 6} SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | 440.14,RECEPTACLE PER 210.63, FOR THE A/C. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-09-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-09-18 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-09-18 |
Time |
08:54 |
Sent To |
Z |
|
Notes |
2008-09-18 08:55:12 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-22 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-14 |
Time |
16:58 |
Sent To |
|
|
Notes |
2008-04-14 16:59:04 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-25 |
Time |
08:43 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-09-25 |
Time |
08:43 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-04-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-16 |
Time |
11:53 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2008-04-16 |
Time |
11:53 |
Sent To |
P |
|
Notes |
2008-04-16 12:16:19 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | 13-101.2.3 | | | | 2) PLEASE SUBMITCOOLING LOAD CALCULATIONS, SEE 2004 | | FBC 13-607.1.ABC.1. | | | | 3) SHOW THE SIZE OF THE SUPPLY AIR TRUNK LINE, SEE | | YELLOW HIGH LIGHT ON PAGE M/P-1, PER 2004 WPB AMEND. | | 106.3.5.4 (10). | | | | 4) SHOW ON MECHANICAL PLAN WHERE THE CLOTHES DRYER VENT | | WILL DISCHARGE TO, SEE 2004 FBC/R R303.4.2. | | | | 5) SHOW THE SEER AND TOTAL COOLING BTU'S FOR THE A/C | | SYSTEM ON THE MECHANICAL PLAN, SEE 2004 FBC | | 13-607.1.ABC.3.1.1. | | | | 6)A/C SYSTEM MODEL NUMBERS LISTED ON THE A/C | | EQUIPMENT SCHEDULE PAGE M/P-1 COULD NOT BE FOUND ON THE | | ARI DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-09-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-09-25 |
Time |
11:13 |
Rev Time |
0.30 |
Received By |
mperson |
Date |
2008-09-25 |
Time |
11:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-04-17 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-04-17 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-04-17 |
Time |
13:09 |
Sent To |
B |
|
Notes |
2008-04-17 13:23:29 | PLUMBING PLAN REVIEW: | | DENIED: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET M/P-1 SANITARY RISER PLEASE CORRECT THE | | FOLLOWING ITEMS. | | | | A} THE WASHING MACHINE DOES NOT REFLECT THE FLOOR PLAN | | ON THE SANITARY RISER. THE SANITARY RISER IS INDICATING | | THE WASHER IN THE EXISTING SCREEN PORCH. PLEASE CORRECT | | THIS PER (W.P.B. AS AMENDED) SECTION 106.1.1 | | INFORMATION ON CONSTRUCTION DOCUMENTS AND FBC PLUMBING | | SECTION 701.1 SCOPE. | | | | B} THE WASHING MACHINE STACK REQUIRES A 3" CLEANOUT TO | | BE LOCATED AT 4' A.F.F. PER FBC PLUMBING SECTION 708.7 | | MINIMUM SIZE AND SECTION 708.9 ACCESS. | | | | C} THE LAVATORY REQUIRES A WATER SEAL TRAP. PER FBC | | PLUMBING SECTION 1002.1 FIXTURE TRAPS. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-09-21 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-09-21 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-09-21 |
Time |
14:57 |
Sent To |
E |
|
Notes |
2008-09-21 14:58:56 | NOTE: AS THE SF7 DESIGNATION DOES NOT ALLOW ACCESSORY | | APARTMENTS, THIS ACCESSORY STRUCTURE SHALL NOT BE USED | | AS A DWELLING UNIT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-04-15 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-04-15 |
Time |
15:54 |
Sent To |
M |
|
Notes |
2008-04-15 15:59:05 | ***FAILED*** | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY. | | | | 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | NOTE:THE MINIMUM REQUIRED SETBACK FROM THE REAR | | PROPERTY LINE TO THE PROPOSED A/C CONDENSOR IS 6.2 | | FEET, THE MINIMUM REQUIRED SETBACK FROM THE WEST SIDE | | PROPERTY LINE TO THE A/C CONDENSOR IS 5.9 FEET. | | | | | | NOTE:AS THE SF7 ZONING DESIGNATION DOES NOT PROVIDE | | FOR ACCESSORY APARTMENTS, THIS ACCESORY STRUCTURE SHALL | | NOT BE USED AS A DWELLING UNIT. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "M" - SF RACK |
|
|