Plan Review Details - Permit 08040313
Plan Review Stops For Permit 08040313
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-09-30 Cont ID  
Sent By rmcdouga Date 2008-09-30 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2008-09-30 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-22 Cont ID  
Sent By rmcdouga Date 2008-04-22 Time 08:47 Rev Time 0.00
Received By rmcdouga Date 2008-04-22 Time 07:04 Sent To  
Notes
2008-04-22 08:44:432004 FBC W/2007 REVISIONS
 CHANGE OF OCCUPANCY
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED. PHONE (561)
 233-5025
  
 3) THE DECLARED VALUE OF THE WORK IS TOO LOW. THE VALUE
 IS REQUIRED TO REFLECT THE COSTS OF LABOR, MATERIALS,
 OVERHEAD AND PROFIT THAT WOULD BE REQUIRED TO CONVERT
 THE GARAGE TO AN OFFICE. INCLUDING ALL OF THE
 UN-PERMITTED WORK. PLEASE REVISE. FBC 108.3* CITY
 AMENDMENTS.
  
 4) SUBMIT TWO COPIES OF ENERGY CALCULATION FORMS AS
 REQUIRED BY FBC 13-600. THE OWNER/AGENT IS REQUIRED TO
 SIGN THE FORMS.
  
 5) SPECIFY THE INSULATION R-VALUES FOR THE WALL AND
 CEILING INSULATION. SEE FBC 13-600.
  
 6) THE CONSTRUCTION TYPE SPECIFIED ON SHEET SP-1 IS
 INCOMPLETE. SPECIFY CONSTRUCTION TYPE VA FOR ONE HOUR
 PROTECTED OR TYPE VB FOR UNPROTECTED. SEE FBC TABLE
 601.
  
 7) THE DOOR TO BATHROOM IS REQUIRED TO HAVE A 29" CLEAR
 OPENING PER FBC EXISTING BUILDING SECTION 812.5 AND FBC
 11-4.22.2.
  
 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EACH TYPE
 OF EXTERIOR DOOR AND STORM PANELS. SPECIFY THE MOUNT
 TYPE, FASTENER TYPE AND SPACING, EDGE DISTANCE, SPANS,
 ETC. FOR THE STORM PANELS.
  
 9) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 10) THE CLASSIFICATION OF WORK ON SHEET SP-1 IS
 INCORRECT. THIS IS CONSIDERED A CHANGE OF OCCUPANCY NOT
 A LEVEL 2 ALTERATION. SEE 2004 FBC EXISTING BUILDING
 CHAPTER 3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-09-25 Cont ID  
Sent By btrobaug Date 2008-09-25 Time 08:07 Rev Time 0.00
Received By btrobaug Date 2008-09-25 Time 06:37 Sent To M
Notes
2008-09-25 08:05:34 
  
 PROVISO
  
 THE CONDENSING UNIT MUST BE A MINIMUM OF 3' FROM THE
 SERVICE. 110.26 NEC
  
 A RECEPTACLE PER 210.63 IS REQUIRED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-15 Cont ID  
Sent By btrobaug Date 2008-04-15 Time 11:36 Rev Time 0.00
Received By btrobaug Date 2008-04-15 Time 10:45 Sent To Z
Notes
2008-04-15 11:34:45 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS
 AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE
 FOLLOWING:
  
 1}INDICATE IF THE ELECTRICAL SERVICE SHOWN ON THE
 PLAN IS NEW OR EXISTING. IF NEW INCLUDE IN THE
 DESCRIPTION ON THE APPLICATION, PROVIDE AN AIC RATING
 PER 110.9 AND 110.10.
  
 2} CIRCUIT #7 BATH LIGHT AND RECEPTACLE HAS AN OCP OF
 30 AMPS WITH A #12 CONDUCTOR IN VIOLATION OF 310.16.
 THIS CIRCUIT IS REQUIRED TO BE 20 AMP PER
 210.11(C)(3).
  
 3} THERE IS A HOT TUB ON THE PANEL SCHEDULE THAT IS NOT
 LOCATED ON THE PLAN. SHEET A-1 INDICATES A SHOWER IN
 THE BATHROOM. SEE 680.43(A)(2) FOR GFCI REQUIREMENTS.
  
 4} THE "MAIN HOUSE SUB PANEL" IS LISTED AT 100 AMPS IN
 PANEL "A", BUT SHOWN AS 110 AMPS ON THE RISER
  
 5} THERE IS NO REFRIGERATOR LISTED IN THE LOAD
 CALCULATIONS, YET ONE IS LISTED IN THE PANEL SCHEDULE
 AND SHOWN ON THE PLAN CONFIRM THAT THERE IS NO OTHER
 APPLIANCES THAT ARE REQUIRED TO BE IN THE LOAD
 CALCULATIONS. CONFIRM THE WATER HEATER IS IN THE MAIN
 HOUSE AND THERE IS NONE IN THE ACCESSORY BUILDING.
  
 6} SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER
 440.14,RECEPTACLE PER 210.63, FOR THE A/C.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-18 Cont ID  
Sent By adarroug Date 2008-09-18 Time 08:54 Rev Time 0.00
Received By adarroug Date 2008-09-18 Time 08:54 Sent To Z
Notes
2008-09-18 08:55:12TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-22 Cont ID  
Sent By rmcdouga Date 2008-04-22 Time 08:47 Rev Time 0.00
Received By rmcdouga Date 2008-04-14 Time 16:58 Sent To  
Notes
2008-04-14 16:59:04TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-09-25 Cont ID  
Sent By tgordon Date 2008-09-25 Time 08:43 Rev Time 0.30
Received By tgordon Date 2008-09-25 Time 08:43 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-04-16 Cont ID  
Sent By tgordon Date 2008-04-16 Time 11:53 Rev Time 0.35
Received By tgordon Date 2008-04-16 Time 11:53 Sent To P
Notes
2008-04-16 12:16:19PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC
 13-101.2.3
  
 2) PLEASE SUBMITCOOLING LOAD CALCULATIONS, SEE 2004
 FBC 13-607.1.ABC.1.
  
 3) SHOW THE SIZE OF THE SUPPLY AIR TRUNK LINE, SEE
 YELLOW HIGH LIGHT ON PAGE M/P-1, PER 2004 WPB AMEND.
 106.3.5.4 (10).
  
 4) SHOW ON MECHANICAL PLAN WHERE THE CLOTHES DRYER VENT
 WILL DISCHARGE TO, SEE 2004 FBC/R R303.4.2.
  
 5) SHOW THE SEER AND TOTAL COOLING BTU'S FOR THE A/C
 SYSTEM ON THE MECHANICAL PLAN, SEE 2004 FBC
 13-607.1.ABC.3.1.1.
  
 6)A/C SYSTEM MODEL NUMBERS LISTED ON THE A/C
 EQUIPMENT SCHEDULE PAGE M/P-1 COULD NOT BE FOUND ON THE
 ARI DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI
 CERTIFICATE, SEE 2004 FBC 13-607.1.ABC.3.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-09-25 Cont ID  
Sent By mperson Date 2008-09-25 Time 11:13 Rev Time 0.30
Received By mperson Date 2008-09-25 Time 11:13 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-17 Cont ID  
Sent By mperson Date 2008-04-17 Time 13:09 Rev Time 0.00
Received By mperson Date 2008-04-17 Time 13:09 Sent To B
Notes
2008-04-17 13:23:29PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET M/P-1 SANITARY RISER PLEASE CORRECT THE
 FOLLOWING ITEMS.
  
 A} THE WASHING MACHINE DOES NOT REFLECT THE FLOOR PLAN
 ON THE SANITARY RISER. THE SANITARY RISER IS INDICATING
 THE WASHER IN THE EXISTING SCREEN PORCH. PLEASE CORRECT
 THIS PER (W.P.B. AS AMENDED) SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS AND FBC PLUMBING
 SECTION 701.1 SCOPE.
  
 B} THE WASHING MACHINE STACK REQUIRES A 3" CLEANOUT TO
 BE LOCATED AT 4' A.F.F. PER FBC PLUMBING SECTION 708.7
 MINIMUM SIZE AND SECTION 708.9 ACCESS.
  
 C} THE LAVATORY REQUIRES A WATER SEAL TRAP. PER FBC
 PLUMBING SECTION 1002.1 FIXTURE TRAPS.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-09-21 Cont ID  
Sent By mcruz Date 2008-09-21 Time 14:59 Rev Time 0.00
Received By mcruz Date 2008-09-21 Time 14:57 Sent To E
Notes
2008-09-21 14:58:56NOTE: AS THE SF7 DESIGNATION DOES NOT ALLOW ACCESSORY
 APARTMENTS, THIS ACCESSORY STRUCTURE SHALL NOT BE USED
 AS A DWELLING UNIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-04-15 Cont ID  
Sent By choops Date 2008-04-15 Time 15:54 Rev Time 0.00
Received By choops Date 2008-04-15 Time 15:54 Sent To M
Notes
2008-04-15 15:59:05***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY.
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 NOTE:THE MINIMUM REQUIRED SETBACK FROM THE REAR
 PROPERTY LINE TO THE PROPOSED A/C CONDENSOR IS 6.2
 FEET, THE MINIMUM REQUIRED SETBACK FROM THE WEST SIDE
 PROPERTY LINE TO THE A/C CONDENSOR IS 5.9 FEET.
  
  
 NOTE:AS THE SF7 ZONING DESIGNATION DOES NOT PROVIDE
 FOR ACCESSORY APARTMENTS, THIS ACCESORY STRUCTURE SHALL
 NOT BE USED AS A DWELLING UNIT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - SF RACK