Plan Review Details - Permit 08040196
Plan Review Stops For Permit 08040196
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-05-15 Cont ID  
Sent By mjacobs Date 2008-05-15 Time 13:50 Rev Time 0.00
Received By mjacobs Date 2008-05-15 Time 12:34 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-14 Cont ID  
Sent By mjacobs Date 2008-04-14 Time 12:09 Rev Time 0.00
Received By mjacobs Date 2008-04-14 Time 12:04 Sent To  
Notes
2008-04-14 12:09:41BUILDING PLAN REVIEW #1
 PERMIT: 08040196
 ADD: 250 S. AUSTRALIAN AVE. #1003
 CONT: FISHER CONTRACTING CONST.
 TEL: (561)691-4716
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 4-14-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 3)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS.
  
 4)THE PERSON TAKING RESPONSIBLE FOR THE DRAWINGS
 SHALL PRINT AND SIGN THEIR NAME ON THE DRAWINGS; THE
 DATE SHALL ALSO BE ON THE DRAWINGS. IF THE DOCUMENTS
 ARE PREPARED BY A DESIGN PROFESSIONAL THEN HE OR SHE
 SHALL AFFIX HIS OR HER OFFICIAL SEAL, SIGNATURE AND
 DATE TO SAID DRAWINGS IN ACCORDANCE WITH FLORIDA
 STATUTES 471 AND 481. FBC 106.1.
  
 5)THE DRAWINGS NEED TO INDICATE CLEARLY WHICH WALLS
 WILL BE DEMOED. IF FIRE RATED OR BEARING WALLS WILL BE
 AFFECTED BY THE DEMOLITION, THEN AN ARCHITECT OR
 ENGINEER SHALL BE RESPONSIBLE FOR THE PLANS. THIS WILL
 BE REQUIRED DUE TO LIFE SAFETY ISSUES OF THE OTHER
 SUITES IN THE BUILDING WHICH WILL NEED TO BE ADDRESSED.
 THE DEMO DRAWING SHALL HAVE A LEGEND SHOWING WHICH
 WALLS WILL REMAIN AND THE ONES TO BE DEMOED.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THE CODE AND RELEVANT LAWS.CONSTRUCTION
 DOCUMENTS SHALL BE DIMENSION AND DRAWN TO A MINIMUM 1/8
 SCALE. FBC 106.1.1
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-05-13 Cont ID  
Sent By btrobaug Date 2008-05-13 Time 08:58 Rev Time 0.00
Received By btrobaug Date 2008-05-13 Time 08:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-14 Cont ID  
Sent By btrobaug Date 2008-04-14 Time 14:27 Rev Time 0.00
Received By btrobaug Date 2008-04-14 Time 14:27 Sent To  
Notes
2008-04-14 14:27:53 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.
  
 2} AN ELECTRICAL PERMIT IS REQUIRED FOR THE DEMOLITION
 OF WALLS AND CEILINGS IN WHICH ELECTRICAL DEVICES OR
 RACEWAYS PASS THROUGH OR TERMINATE. NO ELECTRICAL
 CONTRACTOR WAS SIGNED ON THE APPLICATION, A SEPARATE
 PERMIT APPLICATION IS REQUIRED.105.2 FBC AS AMENDED..
  
 3} INDICATE WHAT IS TO BE DEMOLISHED, WHICH WALLS,
 CEILINGS, ETC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-05-14 Cont ID  
Sent By mwennerg Date 2008-05-14 Time 10:56 Rev Time 0.00
Received By mwennerg Date 2008-05-14 Time 10:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-04-18 Cont ID  
Sent By mwennerg Date 2008-04-18 Time 13:37 Rev Time 0.00
Received By mwennerg Date 2008-04-18 Time 13:37 Sent To  
Notes
2008-04-18 13:37:56***DENIED***
  
 1) PLEASE SEE OTHER REVIEW COMMENTS REGARDING
 REQUIREMENTS FOR PLANS.
  
 2) REQUIRED BUILDING FIRE PROTECTION EQUIPMENT SHALL
 REMAIN OPERATIONAL. PLEASE CONTACT THIS OFFICE AT (561)
 804-4724 SHOULD ANY INTERUPTION OF EQUIPMENT BE
 NECESSARY.
  
 3) REQUIRED MEANS OF EGRESS TO BE MAINTAINED AND
 SEPARATED FROM THE CONSTRUCTION AREA.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-05-06 Cont ID  
Sent By adarroug Date 2008-05-06 Time 10:37 Rev Time 0.00
Received By adarroug Date 2008-05-06 Time 10:37 Sent To  
Notes
2008-05-06 10:37:57TO "BOB"#1

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-18 Cont ID  
Sent By mwennerg Date 2008-04-18 Time 13:40 Rev Time 0.00
Received By mwennerg Date 2008-04-08 Time 14:17 Sent To  
Notes
2008-04-08 14:23:25TO "BOB"#17

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2008-05-06 Cont ID  
Sent By tgordon Date 2008-05-06 Time 14:42 Rev Time 0.20
Received By tgordon Date 2008-05-06 Time 14:42 Sent To  
Notes
2008-05-06 14:42:41PLANS SHOW DEMO. WORK ONLY. NO MECHANICAL PLANS
 SUBMITTED, AND NO MECHANICAL PERMIT NUMBER APPLIED FOR
 AT THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-04-14 Cont ID  
Sent By tgordon Date 2008-04-14 Time 13:50 Rev Time 0.30
Received By tgordon Date 2008-04-14 Time 13:50 Sent To  
Notes
2008-04-14 14:12:34PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) FROM THE PLANS SUBMITTED IT APPEARS YOU WISH TO
 PRODUCE A TENANT SEPARATION WALL, SEE 2004 FBC 708.1.
  
 ***SECTION 708FIRE PARTITIONS
  
 708.1 GENERAL.
 THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS
 SECTION.
 1. WALLS SEPARATING DWELLING UNITS IN THE SAME
 BUILDING.
 2. WALLS SEPARATING SLEEPING UNITS IN OCCUPANCIES
 IN GROUP R-1, HOTEL OCCUPANCIES, R-2 AND I-1.
 3. WALLS SEPARATING TENANT SPACES IN COVERED MALL
 BUILDINGS AS REQUIRED BY SECTION 402.7.2 .
 4. CORRIDOR WALLS AS REQUIRED BY SECTION 1016.1 .
 5.WALL SEPARATING INDIVIDUAL TENANT SPACES.
 (TENANT SEPARATION WALL).
  
 EXCEPTIONS:
 1. IN GROUP B AND S OCCUPANCIES WALLS USED TO
 SEPARATE TENANTS SHALL NOT BE REQUIRED TO HAVE
 FIRE-RESISTANCE RATING, PROVIDED NO AREA BETWEEN FIRE
 PARTITIONS HAVING A 1-HOUR FIRE-RESISTANCE RATING
 EXCEEDS 3,000 SQUARE FEET (279 M 2 ).
  
 2) PLEASE PROVIDE INFORMATION SHOWING COMPLIANCE WITH
 EXCEPTION 1. IF YOU CAN NOT MEET THE EXCEPTION PLEASE
 RATE THE WALL AND SHOW HOW ALL PENETRATIONS WILL COMPLY
 WITH THE 2004 FBC.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-04-17 Cont ID  
Sent By mperson Date 2008-04-17 Time 10:37 Rev Time 0.00
Received By mperson Date 2008-04-17 Time 10:37 Sent To  
Notes
2008-04-17 10:38:49NOTE: THERE IS NO PLUMBING BEING DEMOED IN SUBMITTED
 PLANS.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-04-09 Cont ID  
Sent By choops Date 2008-04-09 Time 14:50 Rev Time 0.00
Received By choops Date 2008-04-09 Time 14:50 Sent To  
Notes
2008-04-09 14:50:18*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.