Plan Review Details - Permit 08040035
Plan Review Stops For Permit 08040035
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 13:30 Rev Time 0.00
Received By btrobaug Date 2008-04-10 Time 13:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 13:36 Rev Time 0.00
Received By btrobaug Date 2008-04-02 Time 09:40 Sent To PC
Notes
2008-04-02 09:44:08TO "BOB"#3

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-04-07 Cont ID  
Sent By mperson Date 2008-04-07 Time 14:02 Rev Time 0.00
Received By mperson Date 2008-04-07 Time 14:02 Sent To  
Notes
2008-04-07 14:10:36****************PROVISO****************
 (A) SHEET 4 PLUMBING NOTE #16: AIR CHAMBERS ARE NOT
 APPROVED BY FBC-2004.
 PER FBC PLUMBING SECTION 604.9 WATER HAMMER. A
 WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE
 QUICK-CLOSING VALVES ARE UTILIZED.
  
 (B) SHEET 5 WATER ISOMETRIC RISER: THERMAL EXPANSION
 CONTROL REQUIRED FOR THE WATER HEATER.
 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE.
 WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR
 OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM
 UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT
 THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A
 DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-04-02 Cont ID  
Sent By choops Date 2008-04-02 Time 10:36 Rev Time 0.00
Received By choops Date 2008-04-02 Time 10:36 Sent To  
Notes
2008-04-02 10:37:29*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.