Plan Review Stops For Permit 08030728 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-01-28 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-01-28 |
Time |
10:47 |
Sent To |
|
|
Notes |
2009-01-28 10:49:15 | CONTRACTOR SUBMITTED PRODUCT APPROVALS FOR STORM PANELS | | AS REQUESTED IN WINDOW REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2009-01-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-01-21 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-01-21 |
Time |
11:02 |
Sent To |
|
|
Notes |
2009-01-21 11:12:32 | STORM SHUTTERS ARE DENIED. | | | | THE REVISION TO CHANGE CHANGE FROM IMPACT TO NON-IMPACT | | WINDOWS IS OK. HOWEVER, THE PRODUCT APPROVALS THAT WERE | | SUBMITTED FOR THE STORM PANELS IS INCOMPLETE AND IS FOR | | THE 2001 CODE VERSION. SUBMIT STORM PANEL PRODUCT | | APPROVALS FOR THE 2004 FBC WITH INSTALLATION | | INSTRUCTIONS. SPECIFY ON THE INSTALLATION INSTRUCTIONS | | THE MOUNTING TYPE (IE. DIRECT MOUNT, H TRACK, ETC.), | | THE FASTENER TYPE AND FASTENER SPACING THAT WILL BE | | USED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-12-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-12-31 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-12-31 |
Time |
10:03 |
Sent To |
|
|
Notes |
2008-12-31 10:06:07 | REVISED INSULATION TO ICYNENE SPRAY FOAM INSULATION. | | SUBMITTED ICC EVALUATION REPORT AND SIGNED AND SEALED | | LETTER AND DRAWING. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-07-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-07-16 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-07-16 |
Time |
14:09 |
Sent To |
|
|
Notes |
2008-07-16 13:35:10 | BUILDING PROVISO | | | | SPECIFY THE FASTENING OPTION AND DESIGN PRESSURE FOR | | THE GAF MODIFIED ROOFING SYSTEM FROM NOA 03-0501.02 | | THAT WILL BE INSTALLED AND SUBMIT RAS 117 CALCULATIONS | | FOR THE ENHANCED FASTENING AT THE PERIMETER AND CORNER | | AREAS OF THE FLAT ROOF. WHEN THE ROOFING PERMIT IS | | APPLIED FOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-06-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-06-17 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-06-17 |
Time |
15:55 |
Sent To |
|
|
Notes |
2008-06-17 15:56:55 | 2004 FBC W/2007 REVISIONS | | LEVEL 3 ALTERATIONS TO DETACHED GARAGE | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | BE REQUIRED. | | | | 2) THE SIGNED AND SEALED SOIL REPORT THAT WAS SUBMITTED | | IS INCOMPLETE. THE SIGNED AND SEALED CALCULATIONS AND | | LETTER SPECIFYING THE BEARING CAPACITY OF THE SOIL FROM | | CUTCHER & ASSOCIATES, INC. ARE MISSING. PLEASE SUBMIT | | TWO SIGNED AND SEALED COPIES. FBC 106.1.2 * CITY | | AMENDMENTS. | | | | 3) THE NEW PLANS ARE REQUIRED TO BE REVIEWED AND | | STAMPED BY THE CITY HISTORIC PLANNERS. | | | | 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE FLAT | | ROOF COVERING. SPECIFY THE APPROVED ASSEMBLY, THE | | FASTENING OPTION AND DESIGN PRESSURE THAT WILL BE | | INSTALLED. SUBMIT RAS 117 CALCULATIONS FOR ENHANCED | | FASTENING. FBC 106.1.2 * CITY AMENDMENTS. | | | | 5) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | EXTERIOR SWING DOOR IS EXPIRED. SUBMIT TWO CURRENT | | PRODUCT APPROVALS FOR THE DOOR. | | | | 6) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-28 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-28 |
Time |
17:36 |
Sent To |
|
|
Notes |
2008-04-28 17:14:26 | 2004 FBC W/2007 REVISIONS | | LEVEL 3 ALTERATIONS TO DETACHED GARAGE | | | | DENIED BY BUILDING 2004 FBC 106.1.2* CITY AMENDMENTS. | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | BE REQUIRED. | | | | 2) A SIGNED, SEALED AND DATED COPY OF THE SOIL REPORT | | IS REQUIRED. SEE FS 471. | | | | 3) SHOW COMPLIANCE WITH FBC R SECTION 704 INSPECTION | | FOR TERMITES IN ORDER TO PROVIDE FOR INSPECTION FOR | | TERMITE INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL | | COVERINGS AND FINAL EARTH GRADE ON THE EXTERIOR OF A | | BUILDING SHALL NOT BE LESS THAN 6 INCHES (152 MM). | | | | 4) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED | | GRADE . | | CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND | | ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT | | ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY | | VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) | | ELSEWHERE. | | | | 5)SHOW COMPLIANCE WITH R320.7 PROTECTION AGAINST | | DECAY AND TERMITES. CONDENSATE LINES AND ROOF | | DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT (305 MM) | | AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY | | UNDERGROUND PIPING, TAIL EXTENSIONS OR SPLASH BLOCKS. | | GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS | | WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL | | PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF | | ABOVE ANOTHER ROOF. | | | | 6)SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED. | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE | | PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 / | | 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM | | OPENINGS. | | | | 7) THE OPENING PRESSURES FOR THE EXTERIOR DOORS LOCATED | | IN WALL ZONE 5 ARE TOO LOW. PLEASE REVISE. SEE TABLE R | | 301.2(2). | | | | 8) THE WALL SECTIONS SPECIFY R-19 INSULATION IN THE | | EXTERIOR WALLS. THE WALLS ARE SPECIFIED AS 2 X 4 WHICH | | CAN ONLY ACCOMODATE R-11 INSULATION. PLEASE REVISE. | | | | 9) TRUSS NOTE (9) ON SHEET A4 NEEDS TO BE REVISED TO | | COMPLY WITH SECTION R803.2.3.1 OF 2006 REVISIONS TO | | 2004 FBC RESIDENTIAL CODE. WOOD STRUCTURAL PANEL | | SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH 8D | | RING-SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND 6 | | INCHES ON CENTER AT INTERMEDIATE FRAMING. WHERE ROOF | | FRAMING WITH A SPECIFIC GRAVITY, 0.42 < G < 0.49 IS | | USED, SPACING OF RING-SHANK FASTENERS SHALL BE 4 INCHES | | ON CENTER IN NAILING ZONE 3 FOR 130 MPH OR GREATER | | DESIGN WIND SPEEDS IN ACCORDANCE WITH FIGURE R803.2.3.1 | | . | | | | 10) ON SHEET A4 MASONRY NOTES 5 AND 6 SPECIFY THE WRONG | | EDITIONS OF ACI 530, ASCE5, ASCE6, TMS402 AND TMS602. | | THE 2002 EDITION OF THESE STANDARDS ARE REFERENCED IN | | THE 2004 FBC. SEE CHAPTER 43 OF THE 2004 FBC | | RESIDENTIAL. | | | | 11) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR WINDOWS, | | DOORS, OVERHEAD GARAGE DOORS, ROOF COVERING, CONNECTORS | | AND STORM PANELS AS REQUIRED BY DCA RULE 9B-72. | | | | 12) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 13) NOTE: THE FLOOR PLAN SPECIFIES AN EGRESS WINDOW AND | | A TEMPERED GLASS WINDOW. BASED ON THE PLANS THAT WERE | | SUBMITTED, THESE WINDOWS ARE NOT REQUIRED TO BE EITHER. | | | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-06-11 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-06-11 |
Time |
12:30 |
Sent To |
P |
|
Notes |
2008-06-11 12:38:59 | | | | | TO SHORT TIME JOHN'S DESK./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-25 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-25 |
Time |
13:48 |
Sent To |
Z |
|
Notes |
2008-04-25 14:36:30 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | FBC CHAPTER 1AS AMENDED. | | | | INDICATE COMPLIANCE WITH THE FOLLOWING ON THE PLAN. | | 1} 230.70 GENERAL. | | MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN | | A BUILDING OR OTHER STRUCTURE FROM THE SERVICE-ENTRANCE | | CONDUCTORS. | | | | 2} 225.32 LOCATION. | | THE DISCONNECTING MEANS SHALL BE INSTALLED EITHER | | INSIDE OR OUTSIDE OF THE BUILDING OR STRUCTURE SERVED | | OR WHERE THE CONDUCTORS PASS THROUGH THE BUILDING OR | | STRUCTURE. THE DISCONNECTING MEANS SHALL BE AT A | | READILY ACCESSIBLE LOCATION NEAREST THE POINT OF | | ENTRANCE OF THE CONDUCTOR | | | | 3} 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) | | OR BRANCH CIRCUIT(S) | | (A) GROUNDING ELECTRODE BUILDING(S) OR STRUCTURE(S) | | SUPPLIED BY FEEDER(S) OR BRANCH CIRCUIT(S) SHALL HAVE A | | GROUNDING ELECTRODE OR GROUNDING ELECTRODE SYSTEM | | INSTALLED IN ACCORDANCE WITH 250.50. THE GROUNDING | | ELECTRODE CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE | | WITH 250.32(B) OR (C). WHERE THERE IS NO EXISTING | | GROUNDING ELECTRODE, THE GROUNDING ELECTRODE(S) | | REQUIRED IN 250.50 SHALL BE INSTALLED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2009-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-20 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-20 |
Time |
14:24 |
Sent To |
B |
|
Notes |
2009-01-20 14:24:46 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-12-19 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-12-19 |
Time |
10:05 |
Sent To |
B |
|
Notes |
2008-12-19 10:06:02 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-10 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-10 |
Time |
16:57 |
Sent To |
P |
|
Notes |
2008-07-10 16:58:13 | TO "MPERSON" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-07-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-09 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-09 |
Time |
09:31 |
Sent To |
Z |
|
Notes |
2008-07-09 09:31:54 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-06-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-12 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-12 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-06-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-05 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-05 |
Time |
09:06 |
Sent To |
Z |
|
Notes |
2008-06-05 09:06:24 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-04-28 |
Time |
17:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-04-25 |
Time |
09:18 |
Sent To |
|
|
Notes |
2008-04-25 09:24:26 | TO "SFR" "E" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-12-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-12-02 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-12-02 |
Time |
16:14 |
Sent To |
PC |
|
Notes |
2008-12-02 16:15:39 | MECH PERMIT #08110536 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-28 |
Time |
10:59 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2008-04-28 |
Time |
10:59 |
Sent To |
P |
|
Notes |
2008-04-28 11:00:37 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-07-11 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-07-11 |
Time |
14:55 |
Sent To |
B |
|
Notes |
2008-07-11 14:58:51 | NOTE: NO PLUMBING ON PLANS, HOWEVER THE SCUPPER AND | | DOWNSPOUT COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | ADDRESSED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-06-16 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-06-16 |
Time |
08:25 |
Sent To |
B |
|
Notes |
2008-06-16 08:55:01 | DENIED; | | 1. SECONDARY ( EMERGENCY)ROOF DRAINS ARE REQUIRED. | | SEE FBC-PLUMBING SECTION 1107.1 , 1107.2 AND 1107.3. | | SHOW ON PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-04-28 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-04-28 |
Time |
12:32 |
Sent To |
B |
|
Notes |
2008-04-28 12:44:27 | DENIED; | | NO PLUMBING WORK SHOWN ON PLANS, BUT PLUMBING | | CONTRACTOR IS SIGNED ON, THE PERMIT APLICATION,AS A | | SUBCONTRACTOR. THERE IS PLUMBING NOTES ON PAGE A-4. | | PLEASE SHOW PLUMBING WORK TO BE DONE ON PLANS WITH A | | SANITARY RISER DIAGRAM AND FIXTURES ON DRAWINGS. IF NO | | PLUMBING WORK WILL BE DONE THEN REMOVE PLUMBING NOTES | | FROM PLANS AND DELETE THE PLUMBING PERMIT NUMBER. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-07-10 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-07-10 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-07-10 |
Time |
15:13 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-06-10 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-06-10 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-06-10 |
Time |
08:54 |
Sent To |
E |
|
Notes |
2008-06-10 08:56:45 | ***FAILED - RESUB #1*** | | | | | | 1)PLANS SHALL BE STAMPED/APPROVED BY THE CITY'S | | HISTORIC PRESERVATION DEPARTMENT. | | | | | | NOTE:THE PROVIDED VARIANCE (#3158) FINAL ORDER HAS | | EXPIRED, HOWEVER, THE DETERMINATION WAS MADE BY THE | | PLANNING DEPARTMENT DIRECTOR THAT NO RENEWAL OF THIS | | VARIANCE WAS NEEDED. | | | | NOTE:THE EXTERIOR WALLS ARE NONCONFORMING WITH | | RESPECT TO THE SIDE AND REAR SETBACKS, ANY WORK THAT IS | | BEING DONE TO THESE AREAS SHALL NOT INCREASE THESE | | NONCONFORMITIES OR CREATE ANY NEW NONCONFORMITIES.THE | | PARAPET/CEILING OF THE STRUCTURE IS ALLOWED TO BE | | RAISED APPROXIMATELY 3'6". | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-04-28 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-04-28 |
Time |
09:55 |
Sent To |
M |
|
Notes |
2008-04-28 09:59:40 | ***APPROVED - NO VARIANCE REQUIRED PER C. WU*** | | | | | | | | | | SENT TO "M" - SF RACK |
|
|