Plan Review Details - Permit 08030526
Plan Review Stops For Permit 08030526
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-06-23 Cont ID  
Sent By shill Date 2008-06-23 Time 16:09 Rev Time 0.00
Received By shill Date 2008-06-23 Time 16:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-04-22 Cont ID  
Sent By shill Date 2008-04-22 Time 11:44 Rev Time 0.00
Received By shill Date 2008-04-22 Time 11:44 Sent To  
Notes
2008-04-22 11:59:50****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.THE NOA SUBMITTED IS EXPIRED8/22/07); PLEASE
 PROVIDE TWO SETS OF THE CURRENT EVALUATION REPORT.
 FAC9B72.THIS MAY BE AVAILABLE AT
 WWW.BUILDINGCODEONLINE.COM
  
 2.SEE PAGE 7 OF THE NOA SUBMITTED.INSULATION
 FASTENER IS TO BE IN ACCORDANCE WITH FASTENER DENSITY
 FOR THE SYSTEM; THE ASSEMBLY YOU HAVE SELECTED
 SPECIFIES 1:4 SF, SO A 4X8 SHEET WOULD REQUIRE 8
 FASTENERS.ON SHEET 10, YOU'VE INDICATED THAT THE
 FIELD WOULD BE INSTALLED WITH 4 FASTENERS.PERIMETER
 AND CORNER FASTENING IS ALSO NOT COMPLIANT WITH THE NOA
 AND RAS117.PLEASE RESOLVE THIS PRIOR TO RESUBMITTAL.
  
  
 3.PLEASE REVISE THE OWNER ON EACH PERMIT APPLICATION
 TO REFECT THE CURRENT OWNER.I HAVE PRINTED PAPA
 RECORDS FOR EACH UNIT FOR YOUR REFERENCE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-04-08 Cont ID  
Sent By shill Date 2008-04-08 Time 08:10 Rev Time 0.00
Received By shill Date 2008-04-08 Time 08:10 Sent To  
Notes
2008-04-08 08:17:16****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.AS DISCUSSED, THE PERMIT WHICH YOU REFER TO WAS
 PROCESSED IN ERROR DUE TO INCORRECT INFORMATION ON THE
 APPLICATION.THAT PERMIT WAS ISSUED FOR THE COMMON
 AREA AS INDICATED BY THE PARCEL ID ON THE APPLICATION,
 BUT THE WORK WAS DONE ON TOWNHOMES.AS DISCUSSED,
 PLEASE PROVIDE THREE ADDITIONAL PERMIT APPLICATIONS;
 ONE FOR EACH ADDRESS/PARCEL ID.REVISE THE SUBMITTED
 APPLICATION TO REFER TO ONLY ONE OF THE TOWNHOUSES WITH
 THE PARCEL ID FOR THAT TOWNHOUSE.THE THREE NEW
 APPLICATIONS SHOULD REFER TO PERMIT 08030526 AS THE
 MASTER PERMIT.ONLY ONE SET OF PAPERWORK WILL BE
 REQUIRED.FEES WILL BE REAPPLIED AFTER SUBMITTAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-03-24 Cont ID  
Sent By shill Date 2008-03-24 Time 14:02 Rev Time 0.00
Received By shill Date 2008-03-24 Time 14:02 Sent To  
Notes
2008-03-24 14:08:40****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.PROVIDE THE EVAULATION REPORT.DESIGN PRESSURE
 LIMITATIONS FOR THIS PRODUCT WERE NOT PROVIDED.
 FAC9B72, FBC CHAPTERS 15 AND 16.
  
 2.A.THE APPLICATION STATES THAT YOU ARE APPLYING TO
 REROOF ONE BUILDING, BUT THERE ARE SEVERAL DIFFERENT
 ADDRESSES ON THE APPLICATION.PLEASE GO TO
 WWW.PBCGOV.COM/PAPA, PRINT THE AERIAL MAP OF THIS
 PARCEL, AND INDICATE WHICH BUILDING IS TO BE INCLUDED
 IN THIS PERMIT IF THIS PERMIT IS FOR A BUILDING WHICH
 IS "COMMON AREA" AS INDICATED ON THE PARCEL ID.
  
 B.IT APPEARS THAT THIS IS A QUADPLEX OF
 TOWNHOMES.IF THIS IS THE CASE, A SEPARATE PERMIT IS
 REQUIRED FOR EACH PARCEL (AND YOU CAN DISREGARD THE
 COMMENT 2A).TWO SETS OF COMPLETE PERMIT DOCUMENTS
 (APPLICATION, PRODUCT APPROVALS, ETC.) ARE REQUIRED FOR
 EACH PERMIT UNLESS YOU "MASTER" ONE SET OF PERMIT
 DOCUMENTS ($250 ADDITIONAL FEE FOR THE MASTER).
  
 3.AS THE INFORMATION REGARDING DESIGN PRESSURES WAS
 NOT PROVIDED, A COMPLETE CHECKLIST CANNOT BE PROVIDED.
 HOWEVER, PLEASE NOTE THAT IF ENHANCED FASTENING IS
 REQUIRED FOR ZONES 2 AND 3 (PERIMETERS AND CORNERS,
 RESPECTIVELY), A LETTER STATING WHAT THAT ENHANCED
 FASTENING PATTERN WILL BE WILL BE REQUIRED.IF THE
 EVALUATION REPORT REQUIRES ENGINEERING, THEN
 ENGINEERING WILL ALSO BE REQUIRED.THIS IS ADVISORY
 AND CANNOT BE DETERMINED UNTIL THE EVALUATION REPORT IS
 PROVIDED.
  
 4.WILL THIS CONTRACTOR BE APPLYING TO REROOF OTHER
 BUILDINGS?IF YES, PLEASE CONTACT ME REGARDING THE
 BEST WAY TO EXPEDITE THIS PROCESS.IF NOT, OR IF THE
 CONTRACTOR WISHES TO CONTINUE TO APPLY FOR PERMITS AS
 USUAL, PLEASE DISREGARD THIS COMMENT.