Plan Review Details - Permit 08030517
Plan Review Stops For Permit 08030517
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-09-26 Cont ID  
Sent By shill Date 2008-09-26 Time 10:33 Rev Time 0.00
Received By shill Date 2008-09-26 Time 10:33 Sent To  
Notes
2008-09-26 10:34:03NEW SHEETS A1, A2

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-08-27 Cont ID  
Sent By shill Date 2008-08-27 Time 10:13 Rev Time 0.00
Received By shill Date 2008-08-27 Time 10:13 Sent To  
Notes
2008-08-27 10:25:31****CORRECTIONS****
 ****BUILDING REVISION #1****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.PLANS ARE NOT CLEAR AS TO SCOPE OF WORK.DETAILS
 FOR INTERIOR AND EXTERIOR WALLS ARE INCLUDED IN THE
 PLAN AS WELL AS NOTES REGARDING WINDOW REPLACEMENT, BUT
 A1 STATES THAT INTERIOR WALLS ARE BEING REPLACED WITH
 NO REFERENCE TO EXTERIOR WALLS OTHER THAN STUCCO.
 PLEASE REVISE TO CLARIFY SCOPE FBC*106.
  
 2.BUILDING TYPE IIA IS DECLARED ON THE PLAN IN ONE
 PLACE ON SHEET A1, BUT CODE INFORMATION STATES THIS IS
 3B; SEE FBC*106, FBC CHAPTER 5.THE DESIGNER SHOULD
 DECLARE MINIMUM BUILDING TYPE REQUIRED BY CODE; THIS IS
 R3 OCCUPANCY SO IT IS NOT CLEAR WHY IIA (NON
 COMBUSTIBLE AND FIRE RESISTANCE RATED STRUCTURAL
 ELEMENTS) AND IIIB HAVE BOTH BEEN DECLARED.DETAILS ON
 THE PLAN SUCH AS 1-A1 SHOW USE OF COMBUSTIBLES.
  
 3.A CHANGE TO THE SCOPE OF WORK IS A REVISION, NOT A
 SUBMITTAL.FEES DUE.FAILURE TO PAY FEES AT TIME OF
 SUBMITTAL MAY RESULT IN DELAYS AS REVIEWS ARE NOT TO BE
 COMPLETED UNTIL ALL FEES ARE PAID.
  
 4.THE VALUE HAS BEEN ADJUSTED TO $40,000.ADDITIONAL
 FEES DUE.
  
 5.WINDOWS, DOORS, IMPACT PROTECTION ARE TO BE ON A
 SEPARATE PERMIT.NO PRODUCT APPROVALS WERE SUBMITTED.
  
 6.PROVIDE DESIGN LOADS FOR ROOF FRAMING; LATERAL,
 PARALLEL, AND UPLIFT, FBC R 301.
  
 7. 1-A1 STATES THAT THE WALL FRAMING WILL BE FASTENED
 INTO THE SLAB, BUT THE GRAPHIC AND OTHER DETAILS SHOW
 FLOOR JOISTS.
  
 8. A-A2 STATES THAT THE ENTIRE ROOF IS NAILED AS AN END
 ZONE.END ZONES ARE TO BE NAILED AT 4" ON THE
 PERIMETER OF THE SHEET, NOT 6".FBC R803.2.3.1.
  
 9. A-A2 STATES: "EXISTING ASPHALT SHINGLES TO MATCH
 EXISTING OVER 30# . . . "; IT IS NOT CLEAR IF THE
 SHINGLES ARE EXISTING, OR A REPAIR, OR NEW.IF THIS IS
 A REPAIR, HOW MUCH WILL BE REPAIRED, FBC EB 511.
 CLARIFY SCOPE OF WORK FBC*106.
  
 10. THE FLOOR JOISTS FOR THIS HOUSE ARE 2X6S, BUT THE
 PLAN SHOWS 2X4S.THE ENGINEER IS TO CONFIRM THAT ALL
 INFORMATION ON THE PLAN IS CORRECT.IT DOES NOT APPEAR
 THAT 2X4 FLOOR JOISTS MEET THE DEAD LOAD, LIVE LOAD,
 AND DEFLECTION REQUIREMENTS.
  
 11.FOR THE PROPOSED 2X4 FLOOR JOISTS IN THE REPAIR
 AREA, PROVIDE CALCULATIONS TO SHOW COMPLIANCE WITH DEAD
 LOADS, LIVE LOADS, AND DEFLECTION.SEE FBC
 R502.2.2(1).
  
 12.SPECIFY SPECIES OF LUMBER.
  
 13.THE FLOOR JOIST REPAIR AREA STATES "FIELD VERIFY
 ATTACHMENT AND REDO IF POSSIBLE."WHAT DOES THIS MEAN?
 YOU ARE INSTALLING NEW FLOOR JOISTS; ATTACHMENT IS NOT
 OPTIONAL.
  
 14.THE PROPOSED 2X4 FLOOR JOISTS ARE SUPPORTING A
 BEARING WALL.PROVIDE CALCULATIONS TO SHOW THAT THE
 2X4S ARE STRUCTURALLY ADEQUATE, FBC R301, FBC EB707.2.
  
 15.AN INTERIOR WALL DETAIL WAS PROVIDED; IS THIS THE
 DETAIL FOR THE BEARING WALL?REPAIR AREA INCLUDES A
 PORTION OF THE BEARING WALL.
  
 16.THE REPAIR AREA INCLUDES AN OPENING (A DOOR) IN
 THE BEARING WALL.PROVIDE A STRUCTURAL DETAIL.
  
 17.ARE THE CEILINGS BEING REPLACED?NOTE ON THE
 PLAN, COMPLIANCE WITH FBC CHAPTER 13 CANNOT BE
 DETERMINED.
  
 18.A SET HAS BEEN RETAINED.TWO SETS WILL BE
 REQUIRED FOR PERMIT ISSUANCE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-04-01 Cont ID  
Sent By lmartine Date 2008-04-01 Time 12:44 Rev Time 0.00
Received By lmartine Date 2008-04-01 Time 12:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-09-15 Cont ID  
Sent By adarroug Date 2008-09-15 Time 09:00 Rev Time 0.00
Received By adarroug Date 2008-09-15 Time 09:00 Sent To P
Notes
2008-09-15 09:00:39TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-01 Cont ID  
Sent By lmartine Date 2008-04-01 Time 12:45 Rev Time 0.00
Received By lmartine Date 2008-03-24 Time 09:17 Sent To  
Notes
2008-03-24 09:18:11TO "MISC" BOX#1

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-09-16 Cont ID  
Sent By mperson Date 2008-09-16 Time 08:52 Rev Time 0.00
Received By mperson Date 2008-09-16 Time 08:52 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-08-28 Cont ID  
Sent By mperson Date 2008-08-28 Time 08:50 Rev Time 0.00
Received By mperson Date 2008-08-28 Time 08:50 Sent To  
Notes
2008-08-28 09:48:26PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A1 SCOPE OF WORK: THE SCOPE OF WORK IS NOT
 CLEAR DUE TO A SUBMITTED SANITARY ISOMETRIC RISER
 DIAGRAM BEING INDICATED ON SHEET A2. PLEASE CLARIFY IF
 IT IS THE INTENT TO REPLACE THE SANITARY SYSTEM WITH
 NEW PIPE IN THE SCOPE OF WORK. PLEASE KNOW THAT A
 PLUMBING PERMIT WILL BE REQUIRED IF THAT IS THE INTENT.
 PER (W.P.B. AS AMENDED) SECTION 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 2. SHEET A2 SANITARY PLUMBING RISER: PLEASE CORRECT
 THE FOLLOWING PER THE FBC-2004 PLUMBING SECTIONS.
  
 A} THE RISER DIAGRAM DOES NOT RELECT THE FLOOR PLAN.
 THE KITCHEN SINK BEING INDICATED ON SHEET A1 HAS TWO
 BOWLS. CLEARLY INDICATE THIS ON THE RESUBMITTAL. PER
 SECTION 701.1 SCOPE.
  
 B} SIZE ALL WASTE PIPING AND WATER-SEAL TRAPS. PER
 SECTION 701.1 SCOPE.
  
 C} HORIZONTAL WASTE PIPING AND STACK FOR THE WASHING
 MACHINE SHALL BE 3 INCH AND THE WASHING MACHINE
 WATER-SEAL TRAP SHALL BE 2 INCH. PER SECTION 406.3
 WASTE CONNECTIONS.
  
 D} A 3 INCH CLEANOUT FOR THE WASHING MACHINE STACK IS
 REQUIRED AND IT SHALL BE LOCATED AT FOUR FEET ABOVE
 FINNISH FLOOR (4" A.F.F.) PER SECTION 708.9 ACCESS.
  
 E} PER THE LOCATION OF THE WASTE STACK FOR THE KITCHEN
 SINK A 2 INCH WASTE ARM IS REQUIRED FOR THE KITCHEN
 SINK. PER TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP
 FROM VENT.
 NOTE: WITH HAVING TO INSTALL A 2 INCH WASTE ARM FOR
 THE KITCHEN SINK PLEASE KNOW THAT THE STRUCTURAL
 INTEGRITY OF THE EXTERIOR WALL IS AFFECTED AND THE WALL
 WILL NEED TO BE INSTALLED PER FBC-2004 RESIDENTIAL
 SECTION R602.2.7 DRILLING AND NOTCHING-STUDS.
  
 F} THE LAVATORY WATER-SEAL TRAP CAN BE EITHER 1-1/4
 INCH OR 1-1/2 INCH. PLEASE KNOW THAT IF ITS SIZED 1-1/4
 INCH A CLEANOUT SHALL BE REQUIRED AT THE BASE OF ITS
 WASTE STACK. PER SECTION 708.7 MINIMUM SIZE, EXCEPTIONS
 (1), AND SECTION 708.3.5 BASE OF STACK.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]