Plan Review Stops For Permit 08030467 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-04-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-04-07 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-04-07 |
Time |
17:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-25 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-25 |
Time |
17:30 |
Sent To |
|
|
Notes |
2008-03-25 17:30:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.PROVIDE A COST BREAKDOWN FOR THIS JOB.VALUE | | APPEARS LOW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-04-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2008-04-04 |
Time |
09:48 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2008-04-04 |
Time |
09:48 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-21 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-21 |
Time |
11:34 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-03-21 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-03-21 |
Time |
14:03 |
Sent To |
B |
|
Notes |
2008-03-21 14:04:23 | NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-03-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-31 |
Time |
16:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-31 |
Time |
16:22 |
Sent To |
P |
|
Notes |
2008-03-31 16:22:45 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-25 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-20 |
Time |
14:31 |
Sent To |
|
|
Notes |
2008-03-20 14:31:21 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-04-02 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-04-02 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-04-02 |
Time |
14:00 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-03-21 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-03-21 |
Time |
13:55 |
Sent To |
G |
|
Notes |
2008-03-21 14:03:23 | PLUMBING PLAN REVIEW: | | DENIED | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | 1. SHEET 2 THE PIPING SCHEMATIC HAS BEEN CROSSED OUT | | ON BOTH SETS. A PIPING SCHEMATIC IS REQUIRED WITH | | EQUIPMENT LAYOUT AND PIPE SIZES THAT REFLECTS THE POOL | | ON SHEET 1. PER (W.P.B.) SECTION 106.1.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS AND 106.1.2 ADDITIONAL DATA. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-03-21 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-03-21 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-03-21 |
Time |
11:04 |
Sent To |
E |
|
Notes |
2008-03-21 11:08:05 | ***APPROVED*** | | | | PROVISOS: | | 1)PATIO OR PAVED AREA SHALL BE DESIGNED TO DRAIN | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT | | PROPERTIES/RIGHTS OF WAY. | | 2)ALL POOLS LOCATED ON A CORNER LOT SHALL BE | | SCREENED AT THE CORNER LOT LINE BY AT LEAST A 42-INCH | | HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, AT THE | | PROPERTY LINE, TO ENSURE PRIVACY. |
|
|