Plan Review Details - Permit 08030167
Plan Review Stops For Permit 08030167
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-03-14 Cont ID  
Sent By rmcdouga Date 2008-03-14 Time 07:53 Rev Time 0.00
Received By rmcdouga Date 2008-03-14 Time 07:21 Sent To  
Notes
2008-03-14 07:55:19PROVISO
 FENCE AND ALARMS SHALL COMPLY WITH BARRIER REQUIREMENTS
 OF R4101.17.1 AND R4101.17.19.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-03-11 Cont ID  
Sent By btrobaug Date 2008-03-11 Time 16:17 Rev Time 0.00
Received By btrobaug Date 2008-03-11 Time 16:13 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-03-12 Cont ID  
Sent By mperson Date 2008-03-12 Time 10:23 Rev Time 0.00
Received By mperson Date 2008-03-12 Time 10:23 Sent To B
Notes
2008-03-12 10:24:37NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-14 Cont ID  
Sent By rmcdouga Date 2008-03-14 Time 07:53 Rev Time 0.00
Received By rmcdouga Date 2008-03-10 Time 12:46 Sent To  
Notes
2008-03-10 12:46:45TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-03-12 Cont ID  
Sent By mperson Date 2008-03-12 Time 10:21 Rev Time 0.00
Received By mperson Date 2008-03-12 Time 10:21 Sent To G
Notes
2008-03-12 10:23:28****************PROVISO****************
 1) FBC-2004 SEC. 424.2.7.2, OR
 FBCR-2004 SEC. R4101.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-03-14 Cont ID  
Sent By choops Date 2008-03-14 Time 13:13 Rev Time 0.00
Received By choops Date 2008-03-14 Time 13:13 Sent To PC
Notes
2008-03-14 13:13:32***APPROVED - LARRY (CONTRACTOR) CALLED AND CHANGED
 INFO. TO MEET REQUIREMENT - 3/14/08***
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-03-11 Cont ID  
Sent By choops Date 2008-03-11 Time 11:13 Rev Time 0.00
Received By choops Date 2008-03-11 Time 11:13 Sent To E
Notes
2008-03-11 11:16:03***FAILED***
  
  
 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.THE
 REQUIRED SETBACK FOR THE EAST SIDE IS 10 FEET, YIELDING
 A REQUIRED SIDE SETBACK OF 6 FEET TO ANY PROPOSED
 MECHANICAL EQUIPMENT.
  
  
 NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT
 TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN
 AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720