Plan Review Stops For Permit 08020666 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-05-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-05-09 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-05-09 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-04-11 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-04-11 |
Time |
06:11 |
Sent To |
|
|
Notes |
2008-04-11 11:00:39 | | | | | BUILDING PLAN REVIEW | | PERMIT: 08020666 | | ADD: 1335 OLD OKEECHOBEE RD | | CONT: MAURO BROTHERS LLC | | TEL: (561)738-4713 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 4-11-08 | | REVIEW: 2ND | | ACTION: DENIED | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | **THIS INFORMATION SHALL BE SHOWN ON PLANS.** | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | 4)OK | | 5)OK | | | | 6)CLEARLY INDICATE THE TOTAL SQUARE FOOT OF THE AREA | | WHERE THE MEZZANINE WILL BE CONSTRUCTED, AND SHOW THE | | ENTIRE FLOOR PLAN ON THE STRUCTURAL DRAWINGS. THE | | BUILDING TYPE SHALL BE INDICATED ON THE DRAWINGS PER | | TABLE 601. | | | | **THE 8X11 SHEET ATTACHED TO THE DRAWINGS SHOWS THE | | AREA OF THE MEZZANINE HOWEVER, THE TOTAL SQUARE FOOT OF | | THE SUITE IS NOT INDICATED AS REQUESTED AND THE ENTIRE | | FLOOR PLAN IS NOT SHOWN. ARE THERE ANY OFFICES BELOW | | THE MEZZANINE? IF SO PLEASE SHOW THE FLOOR PLAN FOR THE | | OFFICE AREA AND ELEVATION DRAWINGS OF THE OFFICES. WHAT | | IS THE FIRE RATING OF THE PARTITION WALLS SEPARATING | | EACH SUITE? ** | | | | **THE BUILDING TYPE NOTED ON THE PLANS IS TYPE 1. TYPE | | 1 BUILDINGS ARE CONSTRUCTED WITH NONCOMBUSTIBLE | | MATERIALS. FBC 602.2 AND TABLE 601. SEE SECTION 603 | | WHERE FIRE-RETARDANT- TREATED WOOD IS PERMITTED IN SOME | | SITUATIONS. STATE THE HEIGHT OF THE BUILDING ON THE | | PLANS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | FAX (561)805-6676 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-03-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-03-06 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-03-06 |
Time |
09:35 |
Sent To |
|
|
Notes |
2008-03-06 12:26:25 | | | BUILDING PLAN REVIEW | | PERMIT: 08020666 | | ADD: 1335 OLD OKEECHOBEE RD | | CONT: MAURO BROTHERS LLC | | TEL: (561)738-4713 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 3-6-08 | | REVIEW: 1ST | | ACTION: DENIED | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | 4)THE ENGINEER NEEDS TO INDICATE WHAT METHOD HE IS | | USING TO DESIGN THE MEZZANINE. THE DESIGN, FABRICATION | | AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS AND | | STRUCTURES SHALL BE IN ACCORDANCE WITH EITHER THE | | AISC-LRFD, AISC 335 OR AISC-HSS. FBC 2205.1. THE OPEN | | WEB JOIST SHALL BE IN ACCORDANCE WITH ONE OF THE | | FOLLOWING STEEL JOIST INSTITUTE SPECIFICATIONS: FBC | | 2206.1 | | 1.STANDARD SPECIFICATIONS FOR OPEN WEB STEEL | | JOISTS, K SERIES. | | 2.STANDARD SPECIFICATIONS FOR LONG SPAN STEEL | | JOISTS, LH SERIES AND DEEP LONG SPAN STEEL | | JOISTS, DLH SERIES. | | 3.STANDARD SPECIFICATIONS FOR JOIST GIRDERS. | | | | 5)F.A.C. 61G15-23.002 THE ENGINEER NEEDS TO SIGN, | | SEAL AND DATE PLANS, SPECIFICATIONS, REPORTS OR OTHER | | DOCUMENTS IMMEDIATELY UNDER THE SIGNATURE OF THE | | PROFESSIONAL ENGINEER. | | | | 6)CLEARLY INDICATE THE TOTAL SQUARE FOOT OF THE AREA | | WHERE THE MEZZANINE WILL BE CONSTRUCTED, AND SHOW THE | | ENTIRE FLOOR PLAN ON THE STRUCTURAL DRAWINGS. THE | | BUILDING TYPE SHALL BE INDICATED ON THE DRAWINGS PER | | TABLE 601. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | FAX (561)805-6676 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-08 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-08 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-04 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-04 |
Time |
08:30 |
Sent To |
|
|
Notes |
2008-03-04 09:24:03 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} SHEET E-2 HAS THE "POWER DENSITY" AT 1.70 W/FT | | SQUARE. PER TABLE 13-415.2.C.1, THE MAXIMUM ALLOWABLE | | DENSITY WOULD BE 0.8, IN WHICH CASE THESE FIXTURES DO | | NOT COMPLY. | | | | 2} INDICATE THE POWER SOURCE FOR THE EMERGENCY LIGHT , | | UNDER POWER LOSS. | | | | 3} THE DESCRIPTION OF WORK ON THEAPPLICATION | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-05-09 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2008-05-09 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2008-05-09 |
Time |
14:57 |
Sent To |
|
|
Notes |
2008-05-09 14:57:55 | SENT TO L. MARTINEZ |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-04-11 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-04-11 |
Time |
15:21 |
Sent To |
|
|
Notes |
2008-04-11 15:54:38 | *****UNSAT***** | | | | *THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | REVIEW COMMENTS STILL NEED TO BE ADDRESSED: | | | | | | 5.THE OCCUPANT LOAD (0) LISTED IN THE GENERAL NOTES | | ON THE STRUCTURAL SHEET IS INCORRECT.BASED UPON | | OCCUPANCY TYPE,LIST THE OCCUPANT LOAD AS PER NFPA | | 101, LIFE SAFETY CODE | | | | 7.HOW WILL FIRE SPRINKLER PROTECTION ABOVE AND | | UNDERNEATH THE MEZZANINE BE ACHIEVED? | | | | *NEW COMMENT: | | | | A.ANY LOOSE PLAN SHEET(S) SHALL BE ATTACHED TO THE | | SUBMITTED PLAN SET(S). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-03-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-03-10 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-03-10 |
Time |
14:34 |
Sent To |
|
|
Notes |
2008-03-10 15:08:32 | *****DENIED***** | | | | | | 1.THE CORRECT ADDRESS, INCLUDING THE SUITE NUMBER, | | SHALL BE LISTED IN THE TITLE BLOCK OF EACH SUBMITTED | | PLAN SHEET.PLEASE BE ADVISED OF THE FOLLOWING:(A) | | SUITE 200 IS SHOWN ON PLAN SHEET FP-1 INSTEAD OF SUITE | | 600(B) THE JOB SITE ADDRESS IS IN WEST PALM BEACH AND | | NOT PALM BEACH AS LISTED IN THE TITLE BLOCK ON SHEETS | | E-1 AND E-2. | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 4.PLEASE INDICATE IF THE BUILDING IS TO BE OCCUPIED | | DURING THE SCOPE OF WORK.IF SO, MEANS OF EGRESS AND | | AND REQUIRED FIRE PROTECTION FEATURES ARE TO BE IN | | PLACE AND CONTINUOUSLY MAINTAINED. | | | | 5.PLEASE LIST THE FOLLOWING FOR THE BUILDING: | | OCCUPANCY TYPE,OCCUPANT LOAD,FIRE ALARM AND/OR FIRE | | SPRINKLER DEVICES, AND ANY OTHER PERTINENT | | INFORMATION. | | | | 6.PLEASE PROVIDE A CLEAR REPRENSENTATION OF THE | | MEZZANINE IN RELATION TO THE FLOOR PLAN INCLUDING EXIT | | LIGHTS/DOORS, EMERGENCY LIGHTS, ETC. | | | | 7.HOW WILL THIS MEZZANINE IMPACT THE EXISTING FIRE | | ALARM DEVICES, IF SO EQUIPPED.IN ADDITION. HOW WILL | | FIRE SPRINKLER PROTECTION UNDERNEATH THE MEZZANINE BE | | ACHIEVED? | | | | 8.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-29 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-29 |
Time |
14:31 |
Sent To |
|
|
Notes |
2008-04-29 14:35:11 | TO "BOB"#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-04-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-07 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-07 |
Time |
09:25 |
Sent To |
|
|
Notes |
2008-04-07 09:28:39 | TO "BOB"#6 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-12 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-27 |
Time |
14:50 |
Sent To |
PC |
|
Notes |
2008-02-27 14:51:12 | TO "BOB"#4 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-05-05 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-05-05 |
Time |
15:23 |
Sent To |
|
|
Notes |
2008-05-05 15:23:37 | PASSED - RESTAMP, 515 SQ. FT. STORAGE MEZZANINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-04-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-04-15 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-04-15 |
Time |
15:45 |
Sent To |
|
|
Notes |
2008-04-15 15:45:43 | PASSED - 515 SQUARE FEET OF STORAGE MEZZANINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-03-12 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-03-12 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-03-12 |
Time |
11:26 |
Sent To |
|
|
Notes |
2008-03-12 11:26:48 | MEZZANINE FOR STORAGE USE ONLY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-28 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-28 |
Time |
10:55 |
Sent To |
|
|
Notes |
2008-02-28 10:55:41 | *ZONING REVIEW NOT REQUIRED; INTERIOR WORK ONLY AND THE | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | IMPROVEMENT VALUE. |
|
|