Plan Review Stops For Permit 08020649 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-06-11 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-06-11 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-05-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-05-27 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-05-27 |
Time |
16:18 |
Sent To |
|
|
Notes |
2008-05-27 16:27:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.SEE ELECTRIC REVIEWER'S FIRST REVIEW.TWO SETS | | REQUIRED FOR PERMIT ISSUANCE, FBC*106. | | | | ONLY ONE PAGE OF THE GUARDIAN INSTALLATION GUIDE, WITH | | SETBACK INFORMATION HIGHLIGHTED, WAS SUBMITTED ALONG | | WITH THE ENTIRE BOOK.I CANNOT DETERMINE WHETHER TWO | | SETS OF THE BOOK ARE REQUIRED AS THIS WAS NOT A PART OF | | MY REVIEW.OTHER TRADES DO REQUIRE SETBACK | | INFORMATION, BUT I CANNOT DETERMINE WHETHER THE ENTIRE | | BOOK IS REQUIRED. | | | | ONLY ONE COPY OF THE INSTALLATION AND OWNER'S MANUAL | | WAS PROVIDED.I CANNOT DETERMINE WHETHER OR NOT THIS | | IS REQUIRED FOR ONE OF THE OTHER REVIEWERS; THIS WAS | | NOT REQUIRED FOR MY REVIEW. | | | | NEITHER ITEM WAS REQUIRED FOR BUILDING REVIEW BUT MAY | | HAVE BEEN REQUIRED BY ANOTHER TRADE.THE MANUAL HAS | | BEEN STAMPED BY ELECTRIC (WHICH INDICATES THAT THIS | | INFORMATION WAS REQUIRED), BUT ONLY ONE SET WAS | | INCLUDED IN THE RESUBMITTAL PACKAGE.THE ELECTRIC | | REVIEWER IS NOT IN THE OFFICE TODAY, SO I AM UNABLE TO | | ASK HIM.HOWEVER, IT IS THE CONTRACTOR'S | | RESPONSIBILITY TO ALWAYS SUBMIT TWO COMPLETE, | | IDENTICAL, COLLATED, BOUND SETS OF PERMIT DOCUMENTS. | | THIS HELPS TO EXPEDITE THE REVIEW PROCESS AND PREVENT | | DELAYS. | | | | PLEASE RESOLVE PAPERWORK ISSUES WITH OTHER TRADES. | | DETERMINE WHICH DOCUMENTS ARE REQUIRED AND PROVIDE TWO | | IDENTICAL SETS AS REQUIRED.IF YOU NEED ASSISTANCE OR | | CLARIFICATION, PLEASE FEEL FREE TO CONTACT ME.I | | APOLOGIZE FOR THE DELAY. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-03-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-10 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-10 |
Time |
12:27 |
Sent To |
|
|
Notes |
2008-03-10 12:27:44 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)PROVIDE ANCHORING INFORMATION TO COMPLY WITH | | FBC1609.1.3, FBC R301; STRUCTURAL MEMBERS AND SYSTEMS, | | AND COMPONENTS AND CLADDING IN A BUILDING OR STRUCTURE | | SHALL BE ANCHORED TO RESIST WIND-INDUCED OVERTURNING, | | UPLIFT AND SLIDING AND TO PROVIDE CONTINUOUS LOAD PATHS | | FOR THESE FORCES TO THE FOUNDATION.WHERE A PORTION OF | | THE RESISTANCE TO THESE FORCES IS PROVIDED BY DEAD | | LOAD, THE MINIMUM DEAD LOAD LIKELY TO BE IN PLACE | | DURING A DESIGN WIND EVENT SHALL BE USED. | | | | 2.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4. | | | | 3.)PROVIDE A DETAIL FOR THE SLAB INCLUDING ALL | | DIMENSIONS AND STRUCTURAL INFORMATION.USE OF A PREFAB | | SLAB REQUIRES CALCULATIONS PREPARED BY AN ENGINEER. | | | | 2.)THE VALUE IS TOO LOW.PROVIDE A REASONABLE VALUE | | OR AN ESTIMATED VALUE WILL BE DONE FOR YOU USING | | MARSHALL & SWIFT. | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH THE | | CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-19 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-05-19 |
Time |
15:29 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-03 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-03 |
Time |
09:06 |
Sent To |
M |
|
Notes |
2008-03-03 09:36:16 | | | | | | | 1} THE VALUE ON THE APPLICATION MUSTINCLUDE THE TOTAL | | COST OF LABOR ANDMATERIAL FOR THE GENERATOR, | | EQUIPMENT(TRANSFER SWITCHES, PANELS ETC.)AND PAD PER | | 108.3 FBC AS AMENDED. | | INCREASE THE VALUE AT THE COUNTER WHENRESUBMITTING, AND | | GET A RECEIPT FROM THEPERMIT CLERK.2} | | | | 2} PROVIDE A LOAD CALCULATION FOR THE LOAD INTENDED TO | | BE SERVED. 215.5. 702.5, 2005 NEC. | | | | 3} INDICATE THE SETBACK OF THE GENERATOR FROM THE | | GARAGE. | | | | 4} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON | | A SITE PLAN, METER ENCLOSURE, DISCONNECTS, ATS AND | | PANELS, SO THAT COMPLIANCE WITH ARTICLES 225 AND 230 | | CAN BE REVIEWED. | | | | 5} TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR | | REVIEW PER 106.1 FBC AS AMENDED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-05-20 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-20 |
Time |
11:44 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2008-03-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-03-06 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-03-06 |
Time |
13:14 |
Sent To |
B |
|
Notes |
2008-03-06 13:23:45 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | GAS PLAN REVIEW: | | DENIED: | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. PROVIDE TWO COPIES OF A SITE PLAN OR SURVEY | | INDICATING ALL DIMENSIONS OF THE PROPOSED GENERATOR | | FROM PROPERTY LINES AND ADJACENT STRUCTURES. PER FBC | | FUEL GAS SECTION 401.1 SCOPE. | | | | 2. PROVIDE TWO SETS OF CONSTRUCTION DOCUMENTS. PER | | CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION 106.1 | | SUBMITTAL DOCUMENTS. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-06 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-06 |
Time |
11:06 |
Sent To |
B |
|
Notes |
2008-06-06 11:06:39 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-15 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-15 |
Time |
12:42 |
Sent To |
Z |
|
Notes |
2008-05-15 12:43:16 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-03-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-10 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-27 |
Time |
12:46 |
Sent To |
|
|
Notes |
2008-02-27 12:47:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-03 |
Time |
14:04 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2008-03-03 |
Time |
14:03 |
Sent To |
G |
|
Notes |
2008-03-03 14:05:25 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT | | PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL | | COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA | | 37.NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | INTAKES. | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | STRUCTURE. | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-19 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-19 |
Time |
09:04 |
Sent To |
E |
|
Notes |
2008-05-19 09:05:37 | ***APPROVED - RESUB #1*** | | | | PROVISO:GENERATOR SHALL BE SETBACK A MINIMUM OF NINE | | (9) FEET FROM THE REAR PROPERTY LINE. | | | | | | | | | | SENT TO "E" - BT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-02-28 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-28 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-28 |
Time |
09:15 |
Sent To |
E |
|
Notes |
2008-02-28 09:16:57 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES.AS PER | | SECTION 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | SETBACK.THE GENERATOR MUST BE A MINIMUM OF NINE (9) | | FEET FROMT THE REAR PROPERTY LINE. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "E" - GEN. RES. BOX |
|
|