Plan Review Details - Permit 08020546
Plan Review Stops For Permit 08020546
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-03-25 Cont ID  
Sent By rmcdouga Date 2008-03-25 Time 16:33 Rev Time 0.00
Received By rmcdouga Date 2008-03-25 Time 16:26 Sent To  
Notes
2008-03-25 16:32:56BUILDING PROVISO
 PERMIT IS BEING ISSUED TO REMODEL BATHS IN AN R3
 OCCUPANCY/ SINGLE FAMILY. THE REMODELED BATHS WILL NOT
 MEET THE ACCESSIBILITY REQUIREMENTS OF AN R4 OCCUPANCY/
 GROUP HOME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-03-04 Cont ID  
Sent By rmcdouga Date 2008-03-04 Time 13:55 Rev Time 0.00
Received By rmcdouga Date 2008-03-04 Time 13:55 Sent To  
Notes
2008-03-04 15:51:012004 FBC W/2007 REVISIONS
 REMODEL 2 BATHROOMS
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOC WILL BE REQUIRED.
  
 2)THERE IS AN OPEN PERMIT (07060731)FOR THIS
 ADDRESS FOR A CHANGE OF OCCUPANCY FROM A SINGLE FAMILY
 RESIDENCE TO A GROUP HOME. SECTION 812.5 OF THE FBC
 EXISTING BUILDING CODE REQUIRES THE BATHROOMS TO COMPLY
 WITH THE ACCESSIBILITY REQUIREMENTS OF FBC CHAPTER 11.
 SUBMIT SIGNED AND SEALED PLANS FROM A FLORIDA LICENSED
 ARCHITECT OR ENGINEER SHOWING COMPLIANCE.
  
 3) SEE COMMENTS OF OTHER TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2008-03-19 Cont ID  
Sent By btrobaug Date 2008-03-19 Time 15:21 Rev Time 0.00
Received By btrobaug Date 2008-03-19 Time 15:08 Sent To P
Notes
2008-03-19 15:09:20 
  
 3/19/08 PERMIT #07060731 FOR "CHANGE OF OCCUPANCY"
 CANCELLED. NO ELEC ON THIS PLAN./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-03-04 Cont ID  
Sent By btrobaug Date 2008-03-04 Time 11:43 Rev Time 0.00
Received By btrobaug Date 2008-03-04 Time 11:38 Sent To M
Notes
2008-03-04 11:41:51 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1).
  
 NOTE: THIS PERMIT CANNOT BE ISSUED UNTILL THE OCCUPANY
 IS DETERMINRD AND APPLICATION NUMBER #07060731 HAS BEEN
 PERMITTED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-17 Cont ID  
Sent By adarroug Date 2008-03-17 Time 14:32 Rev Time 0.00
Received By adarroug Date 2008-03-17 Time 14:32 Sent To E
Notes
2008-03-17 14:33:20TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-04 Cont ID  
Sent By rmcdouga Date 2008-03-04 Time 13:56 Rev Time 0.00
Received By rmcdouga Date 2008-02-25 Time 10:56 Sent To  
Notes
2008-02-25 10:56:55TO "P" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-03-04 Cont ID  
Sent By tgordon Date 2008-03-04 Time 12:20 Rev Time 0.20
Received By tgordon Date 2008-03-04 Time 12:20 Sent To B
Notes
2008-03-04 12:21:12NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-03-24 Cont ID  
Sent By mperson Date 2008-03-24 Time 13:17 Rev Time 0.00
Received By mperson Date 2008-03-24 Time 13:17 Sent To B
Notes
2008-03-24 13:35:47****************PROVISO****************
 PER PHONE CONVERSATION WITH THE CBC, MR. PRATT THIS IS
 AN EXACT FIXTURE CHANGE OUT OF PLUMBING FIXTURES (2 EA)
 W/C, LAVS, AND SHOWER TRIM, WITH ONE NEW FIBERGLASS
 SHOWER BASE WITH NO LAYOUT CHANGES. NOTE: THE
 PREFABRICATED SHOWER SHALL CONFORM TO FBC PLUMBING
 SECTION 417.1 APPROVAL: CONFORM TO ANSI Z124.2, ASME
 A112.19.9M OR CSA B45.5 AND 417.4 SHOWER COMPARTMENTS:
 MINIMUM 900 SQUARE INCHES REQUIRED (30" X 30")
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-03-04 Cont ID  
Sent By mperson Date 2008-03-04 Time 08:14 Rev Time 0.00
Received By mperson Date 2008-03-04 Time 08:14 Sent To E
Notes
2008-03-04 08:24:51PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 1. MORE INFORMATION IS REQUIRED DUE TO THE FACT THAT A
 PLUMBING PERMIT IS BEING APPLIED FOR. PLEASE PROVIDE
 THE FOLLOWING INFORMATION IF IT PERTAINS TO YOUR JOB.
 PER CITY OF WPB AMENDMENTS TO CHAPTER 1, SECTION
 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 A} IF PLUMBING LAYOUT IS THE SAME WITH NO CHANGES,
 PLEASE INDICATE THIS ON THE RESUBMITTED DRAWINGS.
  
 B} IF PLUMBING LAYOUT IS THE SAME AND THE PLUMBING
 FIXTURES ARE TO BE CHANGED, PLEASE INDICATE ON THE
 RESUBMITTED DRAWINGS. "EXACT FIXTURE CHANGEOUT ONLY"
 AND CLEARLY INDICATE WHAT FIXTURES ARE GOING TO BE
 CHANGED.
  
 C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT
 FROM THE EXISTING PLEASE SUBMIT THE FOLLOWING ON
 SEPERATE DRAWINGS.
 A) EXISTING FLOOR PLAN LAYOUT.
 B) NEW PROPOSED FLOOR PLAN LAYOUT AND PLEASE FOLLOW
 WHAT IS REQUIRED IN COMMENT #2.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
 *NOTE: THE SUBMITTED SANITARY RISER DIAGRAM IS NOT AN
 ISOMETRIC AND NONE OF THE FIXTURES ARE CLEARLY
 IDENTIFIED OR IS ANY OF THE PIPING SIZED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]