Plan Review Details - Permit 08020486
Plan Review Stops For Permit 08020486
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-02-25 Cont ID  
Sent By shill Date 2008-02-25 Time 15:10 Rev Time 0.00
Received By shill Date 2008-02-25 Time 15:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-21 Cont ID  
Sent By shill Date 2008-02-21 Time 13:22 Rev Time 0.00
Received By shill Date 2008-02-21 Time 13:22 Sent To  
Notes
2008-02-21 13:25:05****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE
 INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO
 SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT.
 INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE
 MITIGATION.
 THE APPLICATION STATES THAT THE PLYWOOD JOINTS WILL BE
 TAPED.DOES THIS APPLY TO BOTH THE FLAT AND THE
 PITCHED ROOF SECTIONS?
  
 _XX_2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 ____3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_4.)FOR THE FLAT ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS. THE ASSEMBLY SELECTED IS A TILE
 UNDERLAYMENT.
  
 _XX_5.)FOR THE FLAT ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO
 BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED
 ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB
 SHEET).THE ENHANCED FASTENING SUBMITTED IS A
 PHOTOCOPY OF ENGINEERING WHICH REFERS TO A DIFFERENT
 ASSEMBLY FROM THE ONE SELECTED.DOCUMENTS PREPARED BY
 AN ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED, DATED ORIGINALS FS471.
  
 _XX_ 6.)TWO COMPLETE COLLATED SETS OF PERMIT
 DOCUMENTS REQUIRED.