Plan Review Stops For Permit 08020471 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-05-15 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-05-15 |
Time |
08:12 |
Sent To |
PC |
|
Notes |
2008-05-15 08:13:04 | PROCESS PLANS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-04-02 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-04-02 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-04-02 |
Time |
12:00 |
Sent To |
PC |
|
Notes |
2008-04-02 12:24:57 | PROVISOR: | | FBC. 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | SURFACE, TO A HEIGHT OF 4 FEER ABOVE THE FINISH FLOOR. | | NOTE: PAINT ON DRYWALL IS NOT CONSIDERED A HARD | | SURFACE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-02-29 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-02-29 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-02-29 |
Time |
07:02 |
Sent To |
|
|
Notes |
2008-02-29 07:54:32 | PERMIT: 08020471 | | ADD: 2475 MERCER AVE #103 B | | CONT: CUSTOM QUALITY HOMES INC. | | TEL: (561)747-2620 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST 2-29-08 | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | BUILDING PLAN REVIEW | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | 4) 11-4.13.6. MINIMUM MANEUVERING CLEARANCES AT DOORS | | THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL BE AS | | SHOWN IN FIG.25. THE FLOOR OR GROUND AREA WITHIN THE | | REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL. | | | | | | 5)FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS AS | | DETERMINED BY THE BUILDING OFFICIAL. IT SEEMS AS IF | | THERE ARE DIFFERENT SUITES / UNITS AT THIS ADDRESS WITH | | DIFFERENT NUMBERS WHICH WILL REQUIRE SEPARATE PERMITS: | | THE PLANS SHOW A DOOR CONNECTING TWO UNITS. INDICATE | | CLEARLY IF THESE TWO SUITES WILL BE OWNED AND OPERATED | | BY ONE TENANT: IF NOT THE DOOR SHALL BE ELIMINATED, AND | | BE REPLACE WITH THE REQUIRED SEPARATION PARTITION PER | | FBC 708 AND TABLE 302.3.2. PLEASE BE SURE THE PLANS AND | | APPLICATION HAS THE CORRECT SUITE NUMBERS, BECAUSE | | THERE ARE TWO APPLICATIONS WITH THE SAME DRAWINGS WHICH | | SHOW THE WORK IN THE SAME LOCATION AND THE UNIT AS | | #102. FOR MORE INFORMATION ABOUT THE ADDRESSING PLEASE | | CONTACT LILLI @ 822-1239. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-18 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-18 |
Time |
08:48 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-04-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-29 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-29 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-25 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-25 |
Time |
10:09 |
Sent To |
|
|
Notes |
2008-03-25 10:09:44 | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE FLA/COM VERSION 3.00 SUBMITTED HAS NOT YET BEEN | | ADOPTED BY THE FBC. PLEASE SEE 13.400.3 REFERENCES | | VERSION 2.5. | | | | 2} THE CERTIFICATION OF COMPLIANCE MUST BE SIGNED BY | | THE OWNER OR OWNER AGENT. SEE 103.1 (13-103.1) AND PAGE | | #3 OF THE CERTIFICATION. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-02-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-22 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-22 |
Time |
14:44 |
Sent To |
|
|
Notes |
2008-02-22 16:42:42 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} SHEETS A1 AND A2 SHOW THE LOCATION OF THE WORK TO BE | | IN SUITE 102, THE MEP'S INDICATE WORK IN SUITE 103. | | CORRELATE WORK AREA INTENDED, THE APPLICATION ALSO | | INDICATES 103. | | | | 2} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR | | SPACE CONTROLS FOR LIGHTING." STANDARD SWITCHES ARE | | SHOWN ON THE PLAN. | | | | 3} PROVIDE LIGHTING POWER DENSITY COMPLIANCE ON THE | | PLAN, CORRELATING WITH FIXTURE TYPES. NOTE THAT THE | | FORM400A IS FOR "WHOLE BUILDING" AND CANNOT BE USED FOR | | AN INTERIOR BUILD OUT OR RENOVATION AS THIS IS | | OBVIOUSLY NOT THE "WHOLE BUILDING". | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2008-05-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-05-06 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-05-06 |
Time |
12:02 |
Sent To |
|
|
Notes |
2008-05-06 12:33:05 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED;PLAN SHEETS A1, E2.01, AND FA1.01 WERE | | STAMPED, INITIALED, AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-04-01 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-04-01 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-04-01 |
Time |
14:52 |
Sent To |
|
|
Notes |
2008-04-01 15:10:31 | *****DENIED***** | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | 1.THE PROJECT SITE ADDRESS, INCLUDING THE SUITE | | NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED | | PLAN SHEET.HAND DRAWN MARKINGS ON SHEETS E101 THRU | | FA1.01 ARE UNACCEPTABLE | | | | 6.IT IS INDICATED ON SHEET FA1.01 THAT THE BUILDING | | IS FIRE SPRINKLERED.PLEASE SHOW THE LAYOUT OF THE | | SPRINKLER HEADS IN THE TENANT SPACE. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-03-03 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-03-03 |
Time |
12:07 |
Sent To |
|
|
Notes |
2008-03-03 12:15:29 | *****DENIED***** | | | | 1.THE PROJECT SITE ADDRESS, INCLUDING THE SUITE | | NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED | | PLAN SHEET. | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | 4.SPECIFY THE INTERIOR FLOOR FINISH IN TERMS OF CLASS | | I OR CLASS II. | | | | 5.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE | | EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL | | DISTANCE. | | | | 6.IT IS INDICATED ON SHEET FA1.01 THAT THE BUILDING | | IS FIRE SPRINKLERED.PLEASE SHOW THE LAYOUT OF THE | | SPRINKLER HEADS IN THE TENANT SPACE. | | | | 7.PLEASE EXPLAIN THE DOOR BETWEEN THE TWO TENANT | | SPACES.IF THESE ARE DIFFERENT SPACES, HOW WILL TENANT | | SEPARATION BE ACCOMPLISHED. | | | | 8.THE SCOPE OF WORK LOCATION ON SHEET A1 AND A2 DOES | | NOT CORRELATE WITH WHERE IS SHOWN ON THE OTHER | | SUBMITTED PLAN SHEETS. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-08-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-08-06 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-08-06 |
Time |
11:02 |
Sent To |
E |
|
Notes |
2008-08-06 11:05:03 | TO "BTROBUAG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-28 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-28 |
Time |
14:33 |
Sent To |
|
|
Notes |
2008-04-28 15:10:50 | TO "BOB"#9 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-03-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-24 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-24 |
Time |
09:31 |
Sent To |
|
|
Notes |
2008-03-24 09:31:52 | TO "BOB"#5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-03-03 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-02-22 |
Time |
09:55 |
Sent To |
|
|
Notes |
2008-02-22 09:55:22 | TO "BOB"#10 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-04-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-04-30 |
Time |
09:43 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-04-30 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-03-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-03-24 |
Time |
15:48 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2008-03-24 |
Time |
15:48 |
Sent To |
|
|
Notes |
2008-03-24 15:58:16 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | ALSO, PER 2004 FBC 13-103.3. | | | | 2) THE COOLING LOAD CALCULATIONS ARE NOT WITH THE | | ENERGY CALCULATIONS, PLEASE SUBMIT COOLING LOAD | | CALCULATIONS, PER 2004 FBC 13-407.1.ACB.1 | | | | 3) PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND | | SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B. | | AMEND. 106.3. ( REGARDING THE PRODUCT APPROVALS FOR THE | | 12"X12" GREENHECK WALL LOUVERS). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-02-25 |
Time |
10:42 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-02-25 |
Time |
10:42 |
Sent To |
|
|
Notes |
2008-02-25 10:51:40 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT. | | | | 2) THE JOB ADDRESS NEEDS TO BE IN THE TITLE BLOCK ON | | EACH PAGE ON THE PLANS, SEE W.P.B. AMEND. 106.1.3 AND | | F.A.C. 61G1-16.004(3). | | | | 3) PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR 12X12 | | WALL LOUVERS, SEE FS 553.842(1) AND FAC RULE 9B-72, | | 9B-72.005, AND FAC 9B-72.010(31)(G). | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | *** PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED | | IN WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND | | SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B. | | AMEND. 106.3. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-05-15 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-05-15 |
Time |
07:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2008-05-01 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-05-01 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-05-01 |
Time |
13:22 |
Sent To |
|
|
Notes |
2008-05-01 14:20:32 | DENIED; | | 1. DRINKING FOUNTAIN NOT TO FBC-2004 BUILDING CHAPTER | | 11 ACCESSIBILITY CODE. | | A. FREE STANDING DRINKING FOUNTAINS IS | | PERMITED, SECTION 11-4.15.5 WITH A PARALLEL APPROACH, | | 30" X 48". THE LOCATION OF THE DRINKING FOUNTAIN DOES | | NOT ALLOW A PARALLEL APPROACH, WALL LEFT SIDE OF D/F | | PROTRUDES INTO THE CLEARE FLOOR SPACE. | | B. SUBMIT MANUFACTURE SPEC. SHEETS THAT SHOW | | ADA COMPLIANCE. SECTION 11-4.15.2, SPOUT HEIGHT SHALL | | BE NO HIGHER THAN 36". PLUMBING FIXTURE SCHEDULE LISTS | | THE HEIGHT OF D/F AS 40" HIGH. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-03-27 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-03-27 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-03-27 |
Time |
09:02 |
Sent To |
|
|
Notes |
2008-03-27 09:25:50 | DENIED; | | DRINKING FOUNTAIN IS REQUIRED TO BE ACCESSIBILE. THE | | OASIS DRINKING FOUNTAIN MODEL # P3CP IS NOT AHANDICAP | | APPROVED FIXTURE. THE LOCATION OF DRINKING FOUNTAIN | | WILL ALLOW A FRONTAL APPROACH ONLY. SHOW THE CLEAR | | FLOOR SPACE ON THE PLANS 30" X 48". PLEASE REVIEW FBC | | BUILDING CHAPTER 11 SECTIONS 11-4.15.1 THRU 11-4.15.5. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-02-25 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-02-25 |
Time |
13:27 |
Sent To |
|
|
Notes |
2008-02-25 14:27:02 | DENIED; | | 1. SEE ELECTRICAL PLAN REVIEW NOTE # 1. | | 2. SEE MECHANICAL PLAN REVIEW # 2. | | 3. DRINKING FOUNTAIN REQUIRED. SEE FBC PLUMBING TABLE | | 403.1(2B). D/F TO MEET ACCESSIBILITY, SEEFBC BUILDING | | CHAPTER 11 SECTIONS11-4.15.1 THRU 11-4.15.5. | | 4. WALLS WITHIN 2 FEET OF THE TOILET SHALL HAVE A | | SMOOTH HARD SURFACE. PAINT CAN CHIP OR SCRATCH SEE FBC | | BUILDING SECTIONSECTION 1210.2. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2008-02-25 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-25 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-25 |
Time |
08:55 |
Sent To |
|
|
Notes |
2008-02-25 08:55:25 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|