Plan Review Details - Permit 08020471
Plan Review Stops For Permit 08020471
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-05-15 Cont ID  
Sent By mjacobs Date 2008-05-15 Time 08:36 Rev Time 0.00
Received By mjacobs Date 2008-05-15 Time 08:12 Sent To PC
Notes
2008-05-15 08:13:04PROCESS PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-04-02 Cont ID  
Sent By mjacobs Date 2008-04-02 Time 12:25 Rev Time 0.00
Received By mjacobs Date 2008-04-02 Time 12:00 Sent To PC
Notes
2008-04-02 12:24:57PROVISOR:
 FBC. 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER
 CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT
 SURFACE, TO A HEIGHT OF 4 FEER ABOVE THE FINISH FLOOR.
 NOTE: PAINT ON DRYWALL IS NOT CONSIDERED A HARD
 SURFACE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-29 Cont ID  
Sent By mjacobs Date 2008-02-29 Time 08:00 Rev Time 0.00
Received By mjacobs Date 2008-02-29 Time 07:02 Sent To  
Notes
2008-02-29 07:54:32PERMIT: 08020471
 ADD: 2475 MERCER AVE #103 B
 CONT: CUSTOM QUALITY HOMES INC.
 TEL: (561)747-2620
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST 2-29-08
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 BUILDING PLAN REVIEW
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 4) 11-4.13.6. MINIMUM MANEUVERING CLEARANCES AT DOORS
 THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL BE AS
 SHOWN IN FIG.25. THE FLOOR OR GROUND AREA WITHIN THE
 REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL.
  
  
 5)FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS AS
 DETERMINED BY THE BUILDING OFFICIAL. IT SEEMS AS IF
 THERE ARE DIFFERENT SUITES / UNITS AT THIS ADDRESS WITH
 DIFFERENT NUMBERS WHICH WILL REQUIRE SEPARATE PERMITS:
 THE PLANS SHOW A DOOR CONNECTING TWO UNITS. INDICATE
 CLEARLY IF THESE TWO SUITES WILL BE OWNED AND OPERATED
 BY ONE TENANT: IF NOT THE DOOR SHALL BE ELIMINATED, AND
 BE REPLACE WITH THE REQUIRED SEPARATION PARTITION PER
 FBC 708 AND TABLE 302.3.2. PLEASE BE SURE THE PLANS AND
 APPLICATION HAS THE CORRECT SUITE NUMBERS, BECAUSE
 THERE ARE TWO APPLICATIONS WITH THE SAME DRAWINGS WHICH
 SHOW THE WORK IN THE SAME LOCATION AND THE UNIT AS
 #102. FOR MORE INFORMATION ABOUT THE ADDRESSING PLEASE
 CONTACT LILLI @ 822-1239.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-08-18 Cont ID  
Sent By btrobaug Date 2008-08-18 Time 10:55 Rev Time 0.00
Received By btrobaug Date 2008-08-18 Time 08:48 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-04-29 Cont ID  
Sent By btrobaug Date 2008-04-29 Time 09:01 Rev Time 0.00
Received By btrobaug Date 2008-04-29 Time 07:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-03-25 Cont ID  
Sent By btrobaug Date 2008-03-25 Time 10:09 Rev Time 0.00
Received By btrobaug Date 2008-03-25 Time 10:09 Sent To  
Notes
2008-03-25 10:09:44 
  
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED,
 CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE FLA/COM VERSION 3.00 SUBMITTED HAS NOT YET BEEN
 ADOPTED BY THE FBC. PLEASE SEE 13.400.3 REFERENCES
 VERSION 2.5.
  
 2} THE CERTIFICATION OF COMPLIANCE MUST BE SIGNED BY
 THE OWNER OR OWNER AGENT. SEE 103.1 (13-103.1) AND PAGE
 #3 OF THE CERTIFICATION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-02-22 Cont ID  
Sent By btrobaug Date 2008-02-22 Time 16:42 Rev Time 0.00
Received By btrobaug Date 2008-02-22 Time 14:44 Sent To  
Notes
2008-02-22 16:42:42 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} SHEETS A1 AND A2 SHOW THE LOCATION OF THE WORK TO BE
 IN SUITE 102, THE MEP'S INDICATE WORK IN SUITE 103.
 CORRELATE WORK AREA INTENDED, THE APPLICATION ALSO
 INDICATES 103.
  
 2} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR
 SPACE CONTROLS FOR LIGHTING." STANDARD SWITCHES ARE
 SHOWN ON THE PLAN.
  
 3} PROVIDE LIGHTING POWER DENSITY COMPLIANCE ON THE
 PLAN, CORRELATING WITH FIXTURE TYPES. NOTE THAT THE
 FORM400A IS FOR "WHOLE BUILDING" AND CANNOT BE USED FOR
 AN INTERIOR BUILD OUT OR RENOVATION AS THIS IS
 OBVIOUSLY NOT THE "WHOLE BUILDING".
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-05-06 Cont ID  
Sent By mawillia Date 2008-05-06 Time 12:36 Rev Time 0.00
Received By mawillia Date 2008-05-06 Time 12:02 Sent To  
Notes
2008-05-06 12:33:05*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ADDRESSED;PLAN SHEETS A1, E2.01, AND FA1.01 WERE
 STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-04-01 Cont ID  
Sent By mawillia Date 2008-04-01 Time 15:34 Rev Time 0.00
Received By mawillia Date 2008-04-01 Time 14:52 Sent To  
Notes
2008-04-01 15:10:31*****DENIED*****
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE
 PLAN REVIEW STILL NEED TO BE ADDRESSED:
  
 1.THE PROJECT SITE ADDRESS, INCLUDING THE SUITE
 NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.HAND DRAWN MARKINGS ON SHEETS E101 THRU
 FA1.01 ARE UNACCEPTABLE
  
 6.IT IS INDICATED ON SHEET FA1.01 THAT THE BUILDING
 IS FIRE SPRINKLERED.PLEASE SHOW THE LAYOUT OF THE
 SPRINKLER HEADS IN THE TENANT SPACE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-03-03 Cont ID  
Sent By mawillia Date 2008-03-03 Time 12:22 Rev Time 0.00
Received By mawillia Date 2008-03-03 Time 12:07 Sent To  
Notes
2008-03-03 12:15:29*****DENIED*****
  
 1.THE PROJECT SITE ADDRESS, INCLUDING THE SUITE
 NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.SPECIFY THE INTERIOR WALL AND CEILING FINISH
 MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
  
 4.SPECIFY THE INTERIOR FLOOR FINISH IN TERMS OF CLASS
 I OR CLASS II.
  
 5.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL
 DISTANCE.
  
 6.IT IS INDICATED ON SHEET FA1.01 THAT THE BUILDING
 IS FIRE SPRINKLERED.PLEASE SHOW THE LAYOUT OF THE
 SPRINKLER HEADS IN THE TENANT SPACE.
  
 7.PLEASE EXPLAIN THE DOOR BETWEEN THE TWO TENANT
 SPACES.IF THESE ARE DIFFERENT SPACES, HOW WILL TENANT
 SEPARATION BE ACCOMPLISHED.
  
 8.THE SCOPE OF WORK LOCATION ON SHEET A1 AND A2 DOES
 NOT CORRELATE WITH WHERE IS SHOWN ON THE OTHER
 SUBMITTED PLAN SHEETS.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-08-06 Cont ID  
Sent By adarroug Date 2008-08-06 Time 11:02 Rev Time 0.00
Received By adarroug Date 2008-08-06 Time 11:02 Sent To E
Notes
2008-08-06 11:05:03TO "BTROBUAG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-04-28 Cont ID  
Sent By adarroug Date 2008-04-28 Time 14:33 Rev Time 0.00
Received By adarroug Date 2008-04-28 Time 14:33 Sent To  
Notes
2008-04-28 15:10:50TO "BOB"#9

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-03-24 Cont ID  
Sent By adarroug Date 2008-03-24 Time 09:31 Rev Time 0.00
Received By adarroug Date 2008-03-24 Time 09:31 Sent To  
Notes
2008-03-24 09:31:52TO "BOB"#5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-03 Cont ID  
Sent By mawillia Date 2008-03-03 Time 12:07 Rev Time 0.00
Received By mawillia Date 2008-02-22 Time 09:55 Sent To  
Notes
2008-02-22 09:55:22TO "BOB"#10

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-04-30 Cont ID  
Sent By tgordon Date 2008-04-30 Time 09:43 Rev Time 0.45
Received By tgordon Date 2008-04-30 Time 09:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-03-24 Cont ID  
Sent By tgordon Date 2008-03-24 Time 15:48 Rev Time 0.35
Received By tgordon Date 2008-03-24 Time 15:48 Sent To  
Notes
2008-03-24 15:58:16PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-103.3.
  
 2) THE COOLING LOAD CALCULATIONS ARE NOT WITH THE
 ENERGY CALCULATIONS, PLEASE SUBMIT COOLING LOAD
 CALCULATIONS, PER 2004 FBC 13-407.1.ACB.1
  
 3) PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND
 SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B.
 AMEND. 106.3. ( REGARDING THE PRODUCT APPROVALS FOR THE
 12"X12" GREENHECK WALL LOUVERS).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-02-25 Cont ID  
Sent By tgordon Date 2008-02-25 Time 10:42 Rev Time 0.30
Received By tgordon Date 2008-02-25 Time 10:42 Sent To  
Notes
2008-02-25 10:51:40PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT.
  
 2) THE JOB ADDRESS NEEDS TO BE IN THE TITLE BLOCK ON
 EACH PAGE ON THE PLANS, SEE W.P.B. AMEND. 106.1.3 AND
 F.A.C. 61G1-16.004(3).
  
 3) PLEASE SUBMIT PRODUCT APPROVAL OR AN NOA FOR 12X12
 WALL LOUVERS, SEE FS 553.842(1) AND FAC RULE 9B-72,
 9B-72.005, AND FAC 9B-72.010(31)(G).
  
 **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG.
  
 *** PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED
 IN WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL (A SHOP REVIEW STAMP AND
 SIGNATURE WILL MEET THIS REQUIREMENT). SEE W.P.B.
 AMEND. 106.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-05-15 Cont ID  
Sent By jleech Date 2008-05-15 Time 07:19 Rev Time 0.00
Received By jleech Date 2008-05-15 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-05-01 Cont ID  
Sent By jleech Date 2008-05-01 Time 13:42 Rev Time 0.00
Received By jleech Date 2008-05-01 Time 13:22 Sent To  
Notes
2008-05-01 14:20:32DENIED;
 1. DRINKING FOUNTAIN NOT TO FBC-2004 BUILDING CHAPTER
 11 ACCESSIBILITY CODE.
 A. FREE STANDING DRINKING FOUNTAINS IS
 PERMITED, SECTION 11-4.15.5 WITH A PARALLEL APPROACH,
 30" X 48". THE LOCATION OF THE DRINKING FOUNTAIN DOES
 NOT ALLOW A PARALLEL APPROACH, WALL LEFT SIDE OF D/F
 PROTRUDES INTO THE CLEARE FLOOR SPACE.
 B. SUBMIT MANUFACTURE SPEC. SHEETS THAT SHOW
 ADA COMPLIANCE. SECTION 11-4.15.2, SPOUT HEIGHT SHALL
 BE NO HIGHER THAN 36". PLUMBING FIXTURE SCHEDULE LISTS
 THE HEIGHT OF D/F AS 40" HIGH.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-03-27 Cont ID  
Sent By jleech Date 2008-03-27 Time 09:07 Rev Time 0.00
Received By jleech Date 2008-03-27 Time 09:02 Sent To  
Notes
2008-03-27 09:25:50DENIED;
 DRINKING FOUNTAIN IS REQUIRED TO BE ACCESSIBILE. THE
 OASIS DRINKING FOUNTAIN MODEL # P3CP IS NOT AHANDICAP
 APPROVED FIXTURE. THE LOCATION OF DRINKING FOUNTAIN
 WILL ALLOW A FRONTAL APPROACH ONLY. SHOW THE CLEAR
 FLOOR SPACE ON THE PLANS 30" X 48". PLEASE REVIEW FBC
 BUILDING CHAPTER 11 SECTIONS 11-4.15.1 THRU 11-4.15.5.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-02-25 Cont ID  
Sent By jleech Date 2008-02-25 Time 14:09 Rev Time 0.00
Received By jleech Date 2008-02-25 Time 13:27 Sent To  
Notes
2008-02-25 14:27:02DENIED;
 1. SEE ELECTRICAL PLAN REVIEW NOTE # 1.
 2. SEE MECHANICAL PLAN REVIEW # 2.
 3. DRINKING FOUNTAIN REQUIRED. SEE FBC PLUMBING TABLE
 403.1(2B). D/F TO MEET ACCESSIBILITY, SEEFBC BUILDING
 CHAPTER 11 SECTIONS11-4.15.1 THRU 11-4.15.5.
 4. WALLS WITHIN 2 FEET OF THE TOILET SHALL HAVE A
 SMOOTH HARD SURFACE. PAINT CAN CHIP OR SCRATCH SEE FBC
 BUILDING SECTIONSECTION 1210.2.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2008-02-25 Cont ID  
Sent By choops Date 2008-02-25 Time 08:55 Rev Time 0.00
Received By choops Date 2008-02-25 Time 08:55 Sent To  
Notes
2008-02-25 08:55:25*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.