Plan Review Details - Permit 08020384
Plan Review Stops For Permit 08020384 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-03-03 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-03-03 |
Time |
14:13 |
Sent To |
|
|
Notes |
2008-03-03 14:13:33 | REDLINED PLANS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-02-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-21 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-21 |
Time |
07:13 |
Sent To |
|
|
Notes |
2008-02-21 09:01:10 | 2004 FBC W/2007 REVISIONS | | | | DENIED BY BUILDING | | | | 1) SIGNAGE IS REQUIRED TO COMPLY WITH FBC 11-4.6.4. | | SIGNS ERECTED AFTER OCTOBER 1,1996, MUST INDICATE THE | | PENALTY FOR ILLEGAL USE OF THE SPACE. | | | | 2) PLANS APPEAR TO SHOW A 6'-0" RAMP ON SHEET SP2. FBC | | 11-4.8.1 ANY PART OF AN ACCESSIBLE ROUTE WITH A SLOPE | | GREATER THAN 1:20 SHALL BE CONSIDERED A RAMP AND SHALL | | COMPLY WITH FBC 11-4.8.SPECIFY THE SLOPE OF THE | | RAMP. | | | | 3) FBC 11-4.8.5 IF A RAMP RUN HAS A RISE GREATER THAN 6 | | INCHES OR A HORIZONTAL PROJECTION GREATER THAN 72 | | INCHES, THEN IT SHALL HAVE HANDRAILS ON BOTH SIDES. IF | | HANDRAILS ARE REQUIRED PROVIDE A DETAIL SHOWING | | COMPLIANCE WITH ALL THE REQUIREMENTS OF FBC 11-4.8. | | | | 4) SHOW COMPLIANCE WITH FBC 11-4.29.5 DETECTABLE | | WARNINGS AT HAZARDOUS VEHICULAR AREAS. IF A WALK | | CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING | | SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS, OR OTHER | | ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR | | AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED | | BY A CONTINOUS DETECTABLE WARNING WHICH IS 36" WIDE, | | COMPLYING WITH 11-4.29.2. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-29 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-29 |
Time |
09:44 |
Sent To |
B |
|
Notes |
2008-02-29 09:44:39 | TO "RMCDOUGAL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-21 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-19 |
Time |
12:00 |
Sent To |
|
|
Notes |
2008-02-19 12:00:10 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-02-20 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-20 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-20 |
Time |
11:12 |
Sent To |
B |
|
Notes |
2008-02-20 11:13:21 | ***APPROVED*** | | | | PER PB CASE NO. 834G | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|