Plan Review Details - Permit 08020317
Plan Review Stops For Permit 08020317 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-04-01 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-04-01 |
Time |
17:23 |
Sent To |
|
|
Notes |
2008-04-01 17:27:01 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.SEE PREVIOUS LIST.THE CONNECTION TYPE YOU HAVE | | CIRCLED ON THE PRODUCT APPROVAL REQUIRES A CONCRETE | | SUBSTRATE, YOU HAVE SPECIFIED CONCETE BLOCK.PLEASE | | SEE THE ATTACHED PRODUCT APPROVAL WHICH I HAVE | | HIGHLIGHTED. | | | | 2.SEE SHEET 11, YOU HAVE CIRCLED 3" EDGE DISTANCE AND | | THE .83 FACTOR.THIS MEANS THAT THE ANCHOR SPACING IS | | TO MULTIPLIED BY THIS FACTOR; THEREFORE, A 10" ANCHOR | | SPACING WOULD REQURE 8.3".BEFORE RESUBMITTAL, PLEASE | | BE SURE THAT THIS FACTOR WAS APPLIED TO THE ANCHOR | | SPACING. | | | | IF YOU DO NOT UNDERSTAND THE COMMENTS, PLEASE CALL ME | | PRIOR TO RESUBMITTAL TO DISCUSS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-24 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-24 |
Time |
16:38 |
Sent To |
|
|
Notes |
2008-03-24 16:43:01 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.SEE PREVIOUS LIST, ITEM 3, TWO SETS REQUIRED.DUE | | TO WORKLOAD, I AM UNABLE TO MAKE COPIES FOR | | CONTRACTORS.WHEN SUBMITTING, PLEASE BE SURE THAT | | THERE ARE TWO COMPLETE COLLATED SETS FOR PERMIT | | ISSUANCE. | | | | 2.ON THE INSTALLATION SCHEDULE, THE SHUTTER | | CONNECTION MOUNTING TYPE COLUMN WAS LEFT BLANK.THIS | | INFORMATION IS REQUIRED TO DETERMINE CODE COMPLIANCE. | | THIS SHOULD CORRELATE WITH THE ANCHOR SCHEDULES ON | | SHEETS 10-11; FOR INSTANCE, "WALL MOUNTING 1 (SILL #2)" | | OR "WALL MOUNTING 3 (SILL #1)".NOTE THAT SOME | | CONNECTION TYPES REQUIRE POURED CONCRETE, YOU HAVE | | SPECIFIED CONCRETE BLOCK.YOU MUST USE A CONNECTION | | TYPE PERMITTED FOR CONCRETE BLOCK SUBSTRATE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-02-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-13 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-13 |
Time |
15:23 |
Sent To |
|
|
Notes |
2008-02-13 15:26:38 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | _XX_5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | _XX_6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-13 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-13 |
Time |
15:36 |
Sent To |
|
|
Notes |
|
|
|