Plan Review Details - Permit 08020167
Plan Review Stops For Permit 08020167
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-03-04 Cont ID  
Sent By lursu Date 2008-03-04 Time 11:25 Rev Time 0.00
Received By lursu Date 2008-03-04 Time 11:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-03-05 Cont ID  
Sent By jgomez Date 2008-03-05 Time 11:47 Rev Time 0.00
Received By jgomez Date 2008-03-05 Time 11:45 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-14 Cont ID  
Sent By jgomez Date 2008-02-14 Time 16:23 Rev Time 0.00
Received By jgomez Date 2008-02-14 Time 16:23 Sent To PC
Notes
2008-02-14 16:54:27COMMERCIAL SIGN, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- DESIGN CRITERIA NEEDS TO BE UPDATED. USING ASCE
 7-98. NEED TO USE ASCE 7-02 AS ADOPTEDIN THE FBC
 2004.
 ***NOTE: REVISE ORIGINAL DRAWINGS. HANDWRITTEN
 REVISIONS OVER EXISTING NUMBERARE NOT ALLOWED.
  
 2-MISSINGSTRUCTURAL INFORMATION (SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004 TO VERIFY COMPLIANCE WITH THE
 WIND LOADS OF SEC. 1609 FBC 2004):
  
 A) THERE ARE NOT SPECS FOR TYPE AND SIZE OFANCHOR
 TO BE USED TO HOLD LETTERS TO ALUMINUM RACEWAY.
  
 B) WHAT'S THE THICKNESS OF 2"X2" L BRACKET THAT
 HOLDS ALUMINUM RACEWAY TO EXISTING STRUCTURE.
  
 C) "MOUNTING PLATES W/ HARDWARE APPROP. TO WALL
 TYPE"ARE NOTSPECIFICATIONS.HOW CAN ENGINEER
 DETERMINE THAT SIGN WILLWITHSTAND 140MPH WIND LOADS
 IF SPECIFIC ANCHOR IS NOT SPECIFIED.
  
 D) WHAT'S THE SPACING FOR THE 3/8" THRU BOLT
 W/LOCKNUT & WASHER SPECIFIED.COORDINATE WITH ITEM
 2(C) ABOVE.
  
 E)IT'S NOT CLEAR IF THE SIGN IS TO BE ATTACHED TO
 THE "DRYVIT" FASCIA OR TO THE STRUCTURAL MEMBERS THAT
 HOLD THE FASCIA.COORDINATE WITH ITEM 2(C) ABOVE.
 NOTE: FASCIA ALONE MAY NOT BE USED AS A STRUCTURAL
 SUPPORT OF THE SIGN.
  
 3- VALUATION DECLARED INTHE PERMIT APPLICATION IS TOO
 LOW.UPDATE VALUATION TO INCLUDE TOTAL COST FOR THE
 INSTALLATION OF THE SIGN, INCLUDING THE ENGINEERING
 FEES.ALSO,VALUATION TO INCLUDE REMOVAL OF EXISTING
 AWNING AS INDICATED ON PLANS. IF SIGN COMPANY IS NOT
 DOING THE REMOVAL, THEN A SEPARATE PERMIT IS REQUIRED.
 SEC. 108.3 CITY AMENDMENTS TO FBC 2004.
  
 4- NOTICE OF COMMENCEMENT IS REQUIRED BY SEC. 713.13
 FLORIDA STATUTE.
  
 NOTE: ONE SET OF PLANS WILL BE RETAINED IN THIS OFFICE
 TOBE SEND TO THE BOARDOF ENGINEERS FOR REVIEW.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-03-03 Cont ID  
Sent By btrobaug Date 2008-03-03 Time 11:03 Rev Time 0.00
Received By btrobaug Date 2008-03-03 Time 11:03 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-02-14 Cont ID  
Sent By btrobaug Date 2008-02-14 Time 09:48 Rev Time 0.00
Received By btrobaug Date 2008-02-14 Time 09:41 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-02-25 Cont ID  
Sent By adarroug Date 2008-02-25 Time 09:39 Rev Time 0.00
Received By adarroug Date 2008-02-25 Time 09:39 Sent To Z
Notes
2008-02-25 09:42:27TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-02-14 Cont ID  
Sent By jgomez Date 2008-02-14 Time 16:54 Rev Time 0.00
Received By jgomez Date 2008-02-08 Time 09:58 Sent To  
Notes
2008-02-08 09:59:21TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status F Date 2008-03-13 Cont ID  
Sent By choops Date 2008-03-13 Time 16:47 Rev Time 0.00
Received By choops Date 2008-03-13 Time 16:47 Sent To  
Notes
2008-03-13 16:52:25***ONLY PERMITTED ONE (1) SIGN.THE OWNER CALLED
 (3/13/08) AND HAS CHOSEN TO MOVE FORWARD WITH PERMIT
 #08020169 AS THEIR ONE (1) SIGN.THEY NO LONGER WISH
 THIS PERMIT TO MOVE FORWARD.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-02-27 Cont ID  
Sent By choops Date 2008-02-27 Time 13:31 Rev Time 0.00
Received By choops Date 2008-02-27 Time 13:31 Sent To E
Notes
2008-02-27 13:33:22***FAILED - RESUB #1***
  
  
 1)PURSUANT TO SECTION 94-408(D)(1):MAXIMUM NUMBER
 OF SIGNS PER BUILDING: ONE PER EACH INDIVIDUAL BUSINESS
 PLUS TWO ADDITIONAL SIGNS.AS THE PHOTOGRAPHIC
 EVIDENCE SHOWS THE TWO ADDITIONAL SIGNS ALREADY USED BY
 OTHER BUSINESSES WITHIN THE CENTER, THIS BUSINESS SHALL
 ONLY BE PERMITTED ONE (1) SIGN.
  
  
 NOTE:ALL ILLUMINATED SIGNS MUST CONFORM TO THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTIONS 94-402(B), 94-406, AND ANY OTHER
 RESTRICTIONS DESIGNATED BY THE ZONING DISTRICT IN WHICH
 IT IS LOCATED.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2008-02-13 Cont ID  
Sent By choops Date 2008-02-13 Time 09:53 Rev Time 0.00
Received By choops Date 2008-02-13 Time 09:53 Sent To E
Notes
2008-02-13 10:01:47***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY OR SITE
 PLAN SHOWING THE LOCATION OF THE PROPOSED SIGNAGE.
  
 2)PURSUANT TO SECTION 94-408(D)(1):MAXIMUM NUMBER
 OF SIGNS PER BUILDING: ONE PER EACH INDIVIDUAL BUSINESS
 PLUS TWO ADDITIONAL SIGNS.IF THIS BUILDING IS PART OF
 A SHOPPING CENTER OR STRIP MALL, PROVIDE PHOTGRAPHIC
 EVIDENCE, DOCUMENTING THE EXISTING SIGNAGE, SHOWING
 THAT THE "TWO ADDITIONAL SIGNS" MENTIONED ABOVE, HAVE
 NOT BEEN USED ELSEWHERE.
  
  
 NOTE:ALL ILLUMINATED SIGNS MUST CONFORM TO THE CITY
 OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS, SECTIONS 94-402(B), 94-406, AND ANY OTHER
 RESTRICTIONS DESIGNATED BY THE ZONING DISTRICT IN WHICH
 IT IS LOCATED.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720