Plan Review Stops For Permit 08020067 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2010-02-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-02-04 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-02-04 |
Time |
13:44 |
Sent To |
|
|
Notes |
2010-02-04 13:47:40 | CONTRACTOR SUBMITED CORRECTED CHANGE OF DESIGNER OF | | RECORD LETTER FROM THE ARCHITECT WITH SIGNED RECEIPT | | MAIL SLIP. PLANS WITH NEW TITLE BLOCK WERE STAMPED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2010-01-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-01-20 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-01-20 |
Time |
11:17 |
Sent To |
|
|
Notes |
2010-01-20 12:00:15 | 2004 FBC W/2007 REVISIONS | | APPLICATION FOR SUCCESSOR ARCHITECT | | | | DENIED BY BUILDING | | | | 1) TWO SETS OF PLANS, WHICH ARE COPIES OF THE APPROVED | | PLANS WITH THE TITLE BLOCKS CHANGED TO A DIFFERENT | | DESIGNER OF RECORD (ARCHITECT) WERE SUBMITTED. THE | | INTENT OF THE NEW ARCHITECT IS TO ADOPT THE WORK OF THE | | ORIGNIAL DESIGNER OF RECORD AS ALLOWED BY FAC | | 61G1-18.002. THE SIGNED AND SEALED LETTER FROM THE | | SUCCESSOR ARCHITECT STATES THAT A NOTIFICATION LETTER | | WAS SENT TO THE GARRISON DESIGN GROUP. THE DESIGNER OF | | RECORD IS THE ENGINEER THAT SIGNED AND SEALED THE | | ORIGINAL PLANS, LUIS A. LOPEZ, PE # 59805. IN | | ACCORDANCE WITH FAC 61G15-27.001 AND FAC 61G1-18.002 | | THE ORIGINAL ENGINEER IS REQUIRED TO BE NOTIFIED BY | | CERTIFIED LETTER OF THE SUCCESSOR'S INTENTION TO USE | | THE ORIGINAL PROFESSIONAL ENGINEER'S WORK. THE | | SUCCESSOR ARCHITECT OR ENGINEER MUST BE ABLE TO | | DOCUMENT AND PRODUCE UPON REQUEST EVIDENCE THAT HE HAS | | IN FACT RECREATED ALL THE WORK DONE BY THE ORIGINAL | | PROFESSIONAL ENGINEER. FURTHER THE SUCESSOR MUST TAKE | | ALL PROFESSIONAL AND LEGAL RESPONSIBLITY FOR THE | | DOCUMENTS WHICH HE SEALED AND SIGNED AND CAN IN NO WAY | | EXEMPT HIMSELF FROM SUCH FULL RESPONSIBILITY. | | | | PLEASE SUBMIT TWO NEW LETTERS WHICH INDICATE THAT THE | | ABOVE REQUIREMENTS HAVE BEEN MET AND THAT DOCUMENTATION | | CAN BE PROVIDED UPON REQUEST. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2009-03-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-03-09 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-03-09 |
Time |
15:25 |
Sent To |
|
|
Notes |
2009-03-09 15:27:06 | PLANS STAMPED FOR IMPACT FEES AND RE-RECORDED NOC | | SUBMITTED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-03-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-03-02 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-03-02 |
Time |
16:46 |
Sent To |
|
|
Notes |
2009-03-02 16:46:10 | NOTE: PERMIT STATUS WILL BE CHANGED TO 'P' AND PERMIT | | PRINTED WHEN IMPACT FEES HAVE BEEN PAID AND PLANS | | STAMPED BY PALM BEACH COUNTY. | | | | | | BUILDING PROVISO | | | | 1) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE 3'-0" | | X 6'8" ARCHED TOP WOOD ENTRY DOOR FOR APPROVAL PRIOR TO | | INSTALLATION. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-12-04 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-12-04 |
Time |
16:23 |
Sent To |
|
|
Notes |
2008-12-04 16:39:50 | DENIED BY BUILDING | | | | 1) THE NOTICE OF COMMENCEMENT HAS EXPIRED AND WILL NEED | | TO BE RE-RECORDED. THE ACTUAL WORK IS REQUIRED TO START | | WITHIN 90 DAYS OF THE RECORDING. FS 713 | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | ENTRY DOOR IS FOR A GLAZED RADIUS TOP DOUBLE DOOR FROM | | BRANNEN MILLWORK. THIS DOES NOT MATCH THE SINGLE DOOR | | THAT IS SPECIFIED ON THE PLANS. SUBMIT THE CORRECT | | PRODUCT APPROVAL. RULE 9B-72 | | | | 4) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | PGT CASEMENT WINDOWS DOES NOT HAVE A 36" X 66" SIZE | | CONFIGURATION X CASEMENT WINDOW LISTED. THE PLANS | | SPECIFY THIS SIZE FOR WIDOW "E" IN THE SCHEDULE ON | | A1.1. PLEASE CORRECT. FAC RULE 9B-72 | | | | NOTE: ITEMS 3 AND 4 CAN BE "PROVISO-ED" AND THE CORRECT | | PRODUCT APPROVALS SUBMITTED FOR APPROVAL PRIOR TO | | INSTALLATION. ITEMS 1 AND 2 CAN BE ADDRESSED WHEN | | PERMIT IS READY FOR ISSUE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-08-15 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-08-15 |
Time |
09:06 |
Sent To |
|
|
Notes |
2008-08-15 07:26:47 | 2004 FBC W/2007 REVISIONS | | ADDITION AND REMODEL | | | | DENIED BY BUILDING | | | | 1) THE NOTICE OF COMMENCEMENT HAS EXPIRED AND WILL NEED | | TO BE RE-RECORDED. THE ACTUAL WORK IS REQUIRED TO START | | WITHIN 90 DAYS OF THE RECORDING. FS 713 | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) SHEET C1 WHICH CONTAINED THE DESIGN CRITERIA WAS NOT | | RE-SUBMITTED. PLEASE SPECIFY DESIGN CRITERIA ON THE | | PLANS. ( APPLICABLE CODE, WINDSPEED, EXPOSURE CATEGORY, | | ETC.) FBC R301.2 | | | | 4) SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS SEPARATED | | BY LESS THAN 6 FEET (1828 MM) SHALL HAVE NOT LESS THAN | | A ONE-HOUR FIRE-RESISTIVE RATING WITH EXPOSURE FROM | | BOTH SIDES. PROJECTIONS SHALL NOT EXTEND TO A POINT | | CLOSER THAN 4 FEET (1220 MM) FROM AN ADJACENT | | PROJECTION OR WALL. THE PLANS SHOW LESS THAN 6 FEET TO | | THE PROPERTY LINES AT GARAGE AND SECOND FLOOR ADDITION. | | THEREFORE, THE DISTANCE TO THE STRUCTURES ON THE | | ADJACENT LOT ARE REQUIRED TO BE NOTED ON THE SITE PLAN | | AND IF LESS THAN 6 FEET THEN THE WALLS MUST HAVE ONE | | HOUR FIRE RATING AND HAVE NO OPENINGS(R302.2). | | | | 5) PLEASE DO NOT TAPE THE RAS 117 CALCULATIONS TO THE | | SIGNED AND SEALED PLANS (SEE SHEET A4.0) . SOME OF THE | | TEXT IS MISSING FROM THE BOTTOM RIGHT SIDE OF THE RAS | | CALCULATIONS. THE PRODUCT APPROVAL THAT WAS SUBMITTED | | DOES NOT CORRESPOND WITH THE CALCULATIONS. THE PRODUCT | | APPROVAL IS FOR A GAF BUILT-UP ROOF SYSTEM NOA NO. | | 03-0501.05 AND THE CALCULATIONS ARE FOR A FIRESTONE | | SYSTEM NOA NO. 05-0830.10. | | PLEASE COORDINATE. | | | | 6) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | ENTRY DOOR IS NON-IMPACT FOR THE GLAZING. SUBMIT | | PRODUCT APPROVALS FOR THE STORM PANELS FOR THIS DOOR. | | SUBMIT AN INSTALLATION SCHEDULE, SPECIFY THE FASTENER | | TYPE, FASTENER SPACING, MOUNT TYPE, EDGE DISTANCE, | | ETC. | | | | 7) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE | | SIGNED BY THE OWNER/AGENT. FBC CHAPTER 13-6. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-14 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-14 |
Time |
06:59 |
Sent To |
Z |
|
Notes |
2008-02-14 08:34:44 | 2004 FBC W/2007 REVISIONS | | ADDITION AND REMODEL | | | | DENIED BY BUILDING | | | | 1) A NOTICE OF COMMENCEMENT WILL BE REQUIRED. FS | | 713.13 | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) UPDATE THE APPLICABLE CODE ON SHEET C1 TO THE 2004 | | FBC WITH 2007 REVISIONS. | | | | 4) THE FIRM LICENSE NUMBER OR THE CERTIFICATE OF | | AUTHORIZATION NUMBER FOR THE GARRISON DESIGN GROUP IS | | REQUIRED IN THE TITLE BLOCK OF THE PLANS. SEE FAC | | 61G1-16.004 OR 61G15-23.002. | | | | 5) SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS. EXTERIOR | | WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) SHALL | | HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE RATING | | WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL NOT | | EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM AN | | ADJACENT PROJECTION OR WALL. | | | | 6) SHOW COMPLIANCE WITH R302.2 OPENINGS. | | OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF | | A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM | | AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET | | (1828 MM). THIS DISTANCE SHALL BE MEASURED | | PERPENDICULAR TO THE LINE USED TO DETERMINE THE | | SEPARATION DISTANCE. | | | | 7) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS AT THE MAIN | | HOUSE. | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | GREATER. | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED | | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME | | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 | | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS | | LOCATED IN ATTICS. | | | | 8) THE ROOM OFF THE BATHROOM IN THE GUEST HOUSE DOES | | NOT COMPLY WITH R310.1 EMERGENCY ESCAPE AND RESCUE | | REQUIRED. | | BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM | | SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND | | RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE | | SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS | | SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT | | BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. WHERE | | EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY | | SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES | | (1118 MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING | | A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES | | AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS | | PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD | | ENCLOSURE SHALL COMPLY WITH SECTION 310.3 . THE NET | | CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL | | BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY | | ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY | | ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT | | BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED | | WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2 . | | THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE | | PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE | | ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING | | AWAY FROM THE RESIDENCE. PROVIDE AN APPROPRIATE OPENING | | OR SPECIFY ON THE PLAN THAT THIS ROOM IS NOT TO BE USED | | FOR SLEEPING PURPOSES. | | | | 9) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS AT THE | | GUEST HOUSE. | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | GREATER. | | THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 | | INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE | | LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE | | LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED | | HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME | | POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 | | FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS | | LOCATED IN ATTICS. | | | | 10) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED AT | | THE GUEST HOUSE. | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE | | PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 / | | 8 INCH (3.2 MM) MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM | | OPENINGS. | | | | 11) SHOW COMPLIANCE WITH R319.1 LOCATION REQUIRED. IN | | AREAS SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY TABLE | | R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE THE | | USE OF AN APPROVED SPECIES AND GRADE OF LUMBER, | | PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3, | | C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2 | | AND P3, OR DECAY-RESISTANT HEARTWOOD OF REDWOOD, BLACK | | LOCUST, OR CEDARS. 5.WOOD SIDING, SHEATHING AND WALL | | FRAMING ON THE EXTERIOR OF A BUILDING HAVING A | | CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE | | GROUND. | | | | 12) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR | | TERMITES. IN ORDER TO PROVIDE FOR INSPECTION FOR | | TERMITE INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL | | COVERINGS AND FINAL EARTH GRADE ON THE EXTERIOR OF A | | BUILDING SHALL NOT BE LESS THAN 6 INCHES (152 MM). SEE | | A2.0 AND A5.1. | | | | 13) ON SHEET A4.1 IN THE CONNECTOR SCHEDULE THE SIMPSON | | LGT-2 REQUIRES 16-16D SINKERS INTO THE TWO MEMBER | | GIRDER PER THE SIMPSON CATALOG, NOT 1-1/2". PLEASE | | CORRECT. FBC 106.1.1* CITY AMENDMENTS. | | | | 14) THE SIMPSON HGAM 10 SPECIFIED IN THE CONNECTOR | | SCHEDULE IS TESTED AND LISTED FOR MASONRY APPLICATIONS | | NOT AS A WOOD CONNECTOR. PLEASE REVISE. FBC 106.1.1* | | CITY AMENDMENTS. | | | | 15) THE ROOF SLOPE IS SPECIFIED AS 5:12 ON A3.1 AND AS | | 4:12 ON A4.1 AND A5.0. PLEASE CORRECT. FBC 106.1.1* | | CITY AMENDMENTS. | | | | 16) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR | | ROOF ZONES 1,2 AND 3 ON A4.1. SEE TABLE R301.2(2) AND | | FIGURE R301.2(8). | | | | 17) ON SHEET A5.0 THE ROOF TILE ATTACHMENT IS SPECIFIED | | AS (2) 10D NAILS. SMOOTH OR SCREW SHANK NAILS WILL NOT | | PROVIDE AN ADEQUATE MOMENT OF RESISTANCE. PLEASE | | SPECIFY RING SHANK NAILS. FBC R905.3 AND FAC RULE | | 9B-72. | | | | 18)SHOW COMPLIANCE WITH R403.1.4 MINIMUM DEPTH. ALL | | EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES | | (305 MM) BELOW THE UNDISTURBED GROUND SURFACE. REVISE | | SHEET A5.0. | | | | 19) THE PLAN NOTES ON A5.3 SPECIFY BEARING WALLS TO BE | | 1 HOUR FIRE RATED CONSTRUCTION WITH 5/8" TYPE X GYPSUM. | | THE PLANS DO NOT REFLECT THIS. PLEASE REVISE. | | | | 20) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR | | THE WINDOW OPENINGS ON THE PLANS. THEY ARE NOT LISTED | | IN THE SCHEDULE ON A1.1. SEE TABLE R301.2(2). | | | | 21) SPECIFY THE APPROVED ASSEMBLY, FASTENING OPTION, | | AND DESIGN PRESSURE FOR THE GAF BUR SYSTEM. SUBMIT RAS | | 117 CALCULATIONS FOR ENHANCED FASTENING AT PERIMETER | | AND CORNER AREAS AS REQUIRED. SEE LIMITATION #7 OF NOA. | | FBC 106.1.2* CITY AMENDMENTS. | | | | 22) THE PRODUCT APPROVAL NOA THAT WAS SUBMITTED FOR THE | | JELD-WEN DOORS EXPIRED AUGUST 15, 2007. SUBMIT A | | CURRENT NOA. FAC RULE 9B-72 | | | | 23) SUBMIT PRODUCT APPROVALS FOR DOOR #9, WHICH THE | | DOOR SCHEDULE INDICATES HAS A VISION PANEL. FAC RULE | | 9B-72 | | | | 24) SUBMIT PRODUCT APPROVALS FOR DOOR #1 IN THE DOOR | | SCHEDULE, THE ARCHED CEDAR ENTRY DOOR WITH SIDELITES | | AND TRANSOM. FAC RULE 9B-72 | | | | 25) THE PRODUCT APPROVAL SUBMITTED FOR THE MULLIONS | | DOES NOT HAVE ADEQUATE DESIGN PRESSURES TO BE INSTALLED | | BETWEEN THE 10' WIDE FRENCH DOOR/SIDELITE ASSEMBLY AND | | THE TRANSOM WINDOWS ABOVE. PLEASE CORRECT. RULE 9B-72 | | | | 26) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | CALCULATION FORMS. FBC CHAPTER 13-6. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-02-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-02-12 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-02-12 |
Time |
14:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2008-12-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-03 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-03 |
Time |
11:12 |
Sent To |
P |
|
Notes |
2008-12-03 13:18:34 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | COMMENTS FOR SHEETE2. | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | 2} LOCATE ALL SERVICE EQUIPMENT ON THE RISER DIAGRAM. | | IF PANEL "B" IS THE GUEST HOUSE PANEL IT MUST HAVE A | | MAIN BREAKER OR A DISCONNECT PER 225.31, LOCATED PER | | 225.32 AND GROUNDED PER 250.32. | | | | 3} THE WASHER /LAUNDRY CIRCUIT IS NOT LISTED ON THE | | PANEL SCHEDULE. 210.11(C)(2). | | | | 4} THERE ARE TWO GUEST HOUSE WATER HEATERS LISTED IN | | PANEL "B", BUT ONLY ONE SHOWN ON THE FLOOR PLAN, | | CORRELATE SAME.VERIFY THE MAIN HOUSE WATER HEATER IS | | FED FROM PANEL "B", IF IN FACT PANEL "B" IS LOCATED IN | | THE GUEST HOUSE. | | | | 5} A SERVICE RECEPTACLE PER 210.63 IS REQUIRED FOR THE | | ACU FOR THE GUEST HOUSE. | | | | 6} THE LOAD CALCULATION LISTS ALL HEAT STRIPS AT 10000W | | WHICH DOES NOT CORRELATE WITH THE PANEL SCHEDULE OR | | MANUFACTURERS SPEC'S ON M1. | | | | 7} A SEPARATE PERMIT IS REQUIRED FOR THE GENERATOR | | SHOWN ON THE RISER DIAGRAM UNLESS ALL DOCUMENTS | | REQUIRED FOR A RESIDENTIAL GENERATOR ARE SUBMITTED WITH | | THIS APPLICATION. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] | | FAX/:561/805-6676 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-08-04 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-08-04 |
Time |
12:29 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-08-03 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-02-06 |
Time |
08:55 |
Sent To |
M |
|
Notes |
2008-02-06 16:51:28 | | | | | APPLICATION #08020067 | | ELECTRICAL PLAN REVIEW | | 270 BARCELONA ROAD | | 2/6/08 | | WEST PALM BEACH, FL. | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1, AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | ON SHEET E2: | | | | 1} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | SIZE AND TYPE, GROUNDING DETAILS, SERVICE EQUIPMENT AND | | PANEL LOCATIONS PER 215.5 NEC AND 106.3.5.4 FBC. | | INDICATE WHICH IS NEW AND WHICH IS EXISTING. THIS | | INCLUDES THE GUEST HOUSE. | | | | 2} THE LOAD CALCULATION TABLE ON SHEET E2 INDICATES THE | | ?GENERAL LIGHTING? LOADS TO BE ON 20 AMP CIRCUITS WITH | | #14 AWG CONDUCTORS IN VIOLATION OF 310.16, MUST BE #12 | | CONDUCTORS OR 15 AMP BREAKERS WHERE ALLOWED. ALSO NOTE | | THAT THE TABLE INDICATES 21 OF THOSE BRANCH CIRCUITS. | | | | 3} THE THREE SMALL APPLIANCE CIRCUITS LISTED IN THE | | CALCULATION TABLE, ARE CALCULATED AT 1200VA, THOSE | | CIRCUITS ARE REQUIRED TO BE CALCULATED AT 1500VA PER | | 220.52. ALSO NOTE THERE ARE ONLY TWO SMALL APPLIANCE | | CIRCUITS LISTED ON THE PANEL SCHEDULES, CORRELATE SAME. | | NOTE: SEE 210.11(C)(1), TWO PER KITCHEN REQUIRED, CHECK | | PANEL SCHEDULES. | | | | 4} THE GFI?S LISTED AT 3000 VA EACH IN THE CALCULATION | | TABLE, ARE IN VIOLATION OF 210.20(B)(1), 210.21(B)(2), | | AND 310.16, AS THOSE CIRCUITS WOULD NEED TO BE RATED | | FOR 25 AMPS. | | | | 5} THE RANGE IS LISTED AS 2.6 KVA ON A 30 AMP CIRCUIT | | IN PANEL ?A?, CORRELATE WITH THE LOAD CALCULATION, ALSO | | SEE 422.11(A). | | | | 6} THE WATER HEATERS LISTED IN PANELS ?A? AND ?C? ARE | | LISTED AS 2.6 KVA ON A 30 AMP CIRCUIT, SEE COMMENT #5. | | | | 7} THERE ARE TWO ?APPLIANCE? CIRCUITS IN BOTH PANELS | | ?A? AND ?C? @2.6 KVA ON A 20 AMP CIRCUIT IN VIOLATION | | OF 310.16, 210.20(B)(1), AND 210.21(B)(2). INDICATE | | WHAT THESE ?APPLIANCES? ARE ON THE SCHEDULES, SEE | | 408.4.- NEW VERBAGE FOR 2005 NEC: "THE IDENTIFICATION | | SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT | | TO BE DISTINGUISHED FROM ALL OTHERS." | | | | 8} THERE IS ONE DISHWASHER IN THE LOAD CALCULATIONS | | LISTED AS 1200 VA, THERE ARE TWO ON THE PANEL SCHEDULES | | (A & C) LISTED AT 1500 VA, CORRELATE SAME. | | | | 9} THE DISPOSAL IN THE CALCULATION IS LISTED AT 900 VA, | | AND LISTED AS 1500 VA ON A 20 AMP CIRCUIT, IN PANEL | | SCHEDULE ?A?. | | | | 10} THE DRYER IN PANEL SCHEDULE ?A? IS LISTED AT 2600 | | VA, OR 10.8 AMPS, ON A 30 AMP CIRCUIT, AND 5000 VA IN | | THE CALCULATIONS, CORRELATE SAME. | | | | 11} THE ATTIC IN THE GUEST HOUSE MUST COMPLY WITH | | 210.63 AND 210.70(A)(3) SINCE MECHANICAL EQUIPMENT WILL | | BE INSTALLED. | | | | 12} THERE ARE TWO A/C AND AHU?S LISTED AS #1. | | | | SHEET E1: GIVEN THE FACT THAT THERE IS NO WAY TO | | DETERMINE NEW FROM EXISTING, THIS REVIEW IS DONE AS IF | | ALL WORK IS NEW | | | | 1} THE DISCONNECTS FOR THE CONDENSING UNITS DO NOT | | COMPLY WITH 110.26 CLEARANCE REQUIREMENTS. NOTE, ONLY | | TWO SHOWN, THREE IN THE SCHEDULES. | | | | 2} R313.1.1 RESIDENTIAL BUILDING CODE, SMOKE ALARMS | | SHALL BE LOCATED AS REQUIRED IN NEW DWELLINGS WHEN | | REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR. SEE | | ARTICLE FOR COMPLETE TEXT. TWO ARE MISSING FROM THE | | UPPER BEDROOMS, AND ONE DOWNSTAIRS, SEE REVIEWED PLAN. | | ALSO SEE THE DEFINITION OF "SMOKE DETECTORS" 11.8.2.1 | | NFPA-72, CLARIFY IF USING DETECTORS OR ALARMS, TO AVOID | | CONFUSION IN THE FIELD. IF USING DETECTORS INDICATE THE | | LOCATIONS OF THE SOUNDING DEVICES. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2010-03-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-03-29 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-03-29 |
Time |
16:04 |
Sent To |
|
|
Notes |
2010-03-29 16:15:17 | SENT TO R3. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2010-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-03-03 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2010-01-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-01-19 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-01-19 |
Time |
11:19 |
Sent To |
|
|
Notes |
2010-01-19 11:19:50 | RESTAMP ROUTED TO RM DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-10 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-10 |
Time |
10:59 |
Sent To |
E |
|
Notes |
2009-02-10 11:00:19 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-10-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-31 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-31 |
Time |
14:16 |
Sent To |
Z |
|
Notes |
2008-10-31 14:17:14 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-07-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-21 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-21 |
Time |
14:34 |
Sent To |
Z |
|
Notes |
2008-07-21 14:34:27 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-14 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-05 |
Time |
10:03 |
Sent To |
|
|
Notes |
2008-02-05 10:03:16 | TO "Z" BOX |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
N |
Date |
2011-02-17 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2011-02-17 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2011-02-17 |
Time |
10:03 |
Sent To |
|
|
Notes |
2011-02-17 10:04:30 | ***LANDSCAPE NOT REQUIRED*** | | | | PLEASE REFER TO PERMIT NUMBER 11020306 FOR LANDSCAPE | | PERMIT AND PLANS.--RAK |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
P |
Date |
2008-11-21 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2008-11-21 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2008-11-21 |
Time |
11:42 |
Sent To |
PC |
|
Notes |
2008-11-21 12:17:39 | ***LANDSCAPE REVIEW PASSED*** | | | | NOTE ADDED TO PLAN----PROVIDE IRRINGATION IN R-O-W. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2009-03-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-03-03 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-03-03 |
Time |
14:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2008-12-07 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-12-07 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-12-07 |
Time |
14:39 |
Sent To |
PC |
|
Notes |
2008-12-07 14:44:34 | REVIEW #: 3RD | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | NOTE: MECHANICAL PLANS HAVE NOW BEEN SUBMITTED FOR | | REVIEW FOR THE FIRST TIME. ALL PREVIOUS REVIEW COMMENTS | | HAVE BEEN ADDRESSED. PLEASE ADDRESS THE FOLLOWING | | RELATED TO NEW MECHANICAL PLANS: | | | | 1. THE GUEST AREA AND 2ND FLOOR, ALL DUCTS ARE MISSING | | SIZES. PLEASE SHOW THE SIZE OF ALL AIR DISTRIBUTION | | COMPONENTS TO BE INSTALLED IN ORDER TO DEMONSTRATE | | COMPLIANCE WITH FBCR M1601.1 AND M1601.3 AS WELL AS | | M1602.4 FOR BALANCED RETURN AIR. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2008-08-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-04 |
Time |
15:38 |
Rev Time |
1.20 |
Received By |
tgordon |
Date |
2008-08-04 |
Time |
15:38 |
Sent To |
P |
|
Notes |
2008-08-04 16:32:18 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | THE FOLLOWING NOTES ARE FROM THE LAST REVIEW 2-7-08 | | THAT WERE NOT CORRECTED. | | | | 1) THE MAIN HOUSE AND THE GUEST HOUSE CAN NOT BE ON THE | | SAME ENERGY CALCULATION. PLEASE SUBMIT SEPARATE ENERGY | | CALCULATIONS FOR EACH BUILDING, SEE 2004 FBC | | 13-101.2.5.1. (THE OLD ENERGY CALCULATIONS WERE | | RESUBMITTED NOT REVISED ONES). | | | | 2) PLEASE HAVE THE REVISED ENERGY CALCULATIONS SIGNED | | BY OWNER/AGENT ALSO, SEE 2004 FBC 13-600.3.ABC.2. (SEE | | RESPONSE ABOVE #1). | | | | 3) ENERGY CALCULATIONS LINE 8B DOES NOT SHOW THE RAISED | | WOOD FLOOR OR INSULATION, SEE 2004 FBC 13-605.2.A.1.1 | | AND 13-605.1.C.2. PLEASE CORRECT ALSO THE PLANS IF | | NEEDED. (SEE RESPONSE ABOVE #1). | | | | 4) SHOW AN A/C EQUIPMENT SCHEDULE WITH ALL THE | | PERTINENT INFORMATION ON THE MECHANICAL PLAN, SEE 2004 | | WPB AMEND. 106.3.5.4 (10). (NO MECHANICAL PLANS WERE | | SUBMITTED FOR REVIEW). | | | | 5) SHOW ALL THE BATHROOM EXHAUST FANS ON THE MECHANICAL | | PLAN AS THEY ARE ON THE ELECTRICAL PLAN, SEE 2004 FBC/R | | R303.3 EXCEPT. (SEE RESPONSE ABOVE #4). | | | | 6) SHOW THE LOCATION OF THE GUEST HOUSE A/C CONDENSER | | UNIT ON THE MECHANICAL AND ELECTRICAL PLANS, SEE 2004 | | FBC/R M1307. (SEE RESPONSE ABOVE #4). | | | | 7) A/C SYSTEM 2 COOLING LOAD CALCULATIONS ARE CALLING | | FOR 23,601 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT | | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN | | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 | | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. (REVISED COOLING | | LOAD CALCULATIONS WERE SUBMITTED BUT NO MECHANICAL | | PLANS WERE SUBMITTED). | | | | 8) A/C SYSTEM 3 COOLING LOAD CALCULATIONS ARE CALLING | | FOR 23,046 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT | | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN | | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 | | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. (SEE RESPONSE | | ABOVE #7). | | | | 9) ELECTRICAL PLAN E-2 IS SHOWING A GAS INSTA-HOT WATER | | HEATER IN THE GARAGE OF THE GUEST HOUSE, THIS MAY BE A | | CONFINED SPACE. PLEASE SUBMIT COMBUSTION AIR | | CALCULATIONS, SEE 2004 FBC/R G2407.5. (THE GAS | | APPLIANCE MAY BE INSTALLED UNDER A SEPARATE PERMIT BUT | | THE SPACE THE GAS APPLIANCE IS BEING INSTALLED IN IS | | PART OF THIS PERMIT, PLEASE COMPLY). | | | | 10) PLEASE SUBMIT MANUFACTURER'S SPECIFICATION'S FOR | | THE GAS INSTA-HOT WATER HEATER AND GAS WATER HEATER | | BEING INSTALLED IN MAIN HOUSE, PER 2004 FBC/R G2407.1. | | (SEE RESPONSE ABOVE #9). | | | | 11) NEW NOTE: PLANS SHOW A GAS WATER HEATER BEING | | INSTALLED IN A CLOSET OF THE MAIN HOUSE FIRST FLOOR. | | THIS MAY BE A CONFINED SPACE, PLEASE SUBMIT COMBUSTION | | AIR CALCULATIONS, PER 2004 FBC/R G2407.5. | | | | 12) NOTICE: SEE ATTACHED NOTICE FS 553.80 (2) (B) | | REGARDING FOUR TIMES THE FEE. | | | | *** 2004 FBC/R G2407.1 (304.1) GENERAL. | | AIR FOR COMBUSTION, VENTILATION AND DILUTION OF FLUE | | GASES FOR GAS UTILIZATION EQUIPMENT INSTALLED IN | | BUILDINGS SHALL BE PROVIDED BY APPLICATION OF ONE OF | | THE METHODS PRESCRIBED IN SECTIONS G2407.5 THROUGH | | G2407.9 . WHERE THE REQUIREMENTS OF SECTION G2407.5 ARE | | NOT MET, OUTDOOR AIR SHALL BE INTRODUCED IN ACCORDANCE | | WITH ONE OF THE METHODS PRESCRIBED IN SECTIONS G2407.6 | | THROUGH G2407.9 . DIRECT-VENT APPLIANCES, GAS | | APPLIANCES OF OTHER THAN NATURAL DRAFT DESIGN AND | | VENTED GAS APPLIANCES OTHER THAN CATEGORY I SHALL BE | | PROVIDED WITH COMBUSTION, VENTILATION AND DILUTION AIR | | IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER?S | | INSTRUCTIONS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-02-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-02-07 |
Time |
09:36 |
Rev Time |
1.15 |
Received By |
tgordon |
Date |
2008-02-07 |
Time |
09:36 |
Sent To |
P |
|
Notes |
2008-02-07 10:02:58 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) THE MAIN HOUSE AND THE GUEST HOUSE CAN NOT BE ON THE | | SAME ENERGY CALCULATION. PLEASE SUBMIT SEPARATE ENERGY | | CALCULATIONS FOR EACH BUILDING, SEE 2004 FBC | | 13-101.2.5.1. | | | | 2) PLEASE HAVE THE REVISED ENERGY CALCULATIONS SIGNED | | BY OWNER/AGENT ALSO, SEE 2004 FBC 13-600.3.ABC.2. | | | | 3) ENERGY CALCULATIONS LINE 8B DOES NOT SHOW THE RAISED | | WOOD FLOOR OR INSULATION, SEE 2004 FBC 13-605.2.A.1.1 | | AND 13-605.1.C.2. PLEASE CORRECT ALSO THE PLANS IF | | NEEDED. | | | | 4) SHOW AN A/C EQUIPMENT SCHEDULE WITH ALL THE | | PERTINENT INFORMATION ON THE MECHANICAL PLAN, SEE 2004 | | WPB AMEND. 106.3.5.4 (10). | | | | 5) SHOW ALL THE BATHROOM EXHAUST FANS ON THE MECHANICAL | | PLAN AS THEY ARE ON THE ELECTRICAL PLAN, SEE 2004 FBC/R | | R303.3 EXCEPT. | | | | 6) SHOW THE LOCATION OF THE GUEST HOUSE A/C CONDENSER | | UNIT ON THE MECHANICAL AND ELECTRICAL PLANS, SEE 2004 | | FBC/R M1307. | | | | 7) A/C SYSTEM 2 COOLING LOAD CALCULATIONS ARE CALLING | | FOR 23,601 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT | | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN | | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 | | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. | | | | 8) A/C SYSTEM 3 COOLING LOAD CALCULATIONS ARE CALLING | | FOR 23,046 TOTAL COOLING BTU'S. A 3 TON A/C SYSTEM AT | | 34,200 TOTAL COOLING BTU'S WOULD BE TO LARGE AS YOU CAN | | ONLY GO 15% OVER THE COOLING LOAD CALCULATION, SEE 2004 | | FBC 13-607.1.ABC.1.1. PLEASE CORRECT. | | | | 9) ELECTRICAL PLAN E-2 IS SHOWING A GAS INSTA-HOT WATER | | HEATER IN THE GARAGE OF THE GUEST HOUSE, THIS MAY BE A | | CONFINED SPACE. PLEASE SUBMIT COMBUSTION AIR | | CALCULATIONS, SEE 2004 FBC/R G2407.5. | | | | 10) PLEASE SUBMIT DETAILED MANUFACTURER'S | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE | | GAS INSTA-HOT WATER HEATER AND ALL OTHER GAS APPLIANCES | | BEING INSTALLED. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2009-02-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2009-02-26 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2009-02-26 |
Time |
15:41 |
Sent To |
M |
|
Notes |
2009-02-26 15:42:00 | PASSED PROVISO -- TABLE 909.3. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-12-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-04 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-04 |
Time |
10:23 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2008-08-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-08-05 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-08-05 |
Time |
10:46 |
Sent To |
B |
|
Notes |
2008-08-05 11:13:54 | PLUMBING PLAN REVIEW: | | DENIED **2ND TIME: | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW | | COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW | | COMMENTS. | | | | 1. "OK" COMMENT ADDRESSED. | | | | 2. THE GAS WATER HEATER IN THE GUEST HOUSE GARAGE, | | SHOW HOW IT WILL BE VENTED TO THE OUTSIDE. PROVIDE | | MANUFACTURER'S SPECIFICATIONS. | | | | **RESPONSE NOTED, HOWEVER COMMENT HAS NOT BEEN | | ADDRESSED. PLEASE KNOW THAT THE GAS APPLIANCE AND | | PIPING MAY BE INSTALLED UNDER A SEPERATE PERMIT, | | HOWEVER THE SPACE THE GAS APPLIANCE IS BEING INSTALLED | | IN IS PART OF THIS PERMIT AND THE COMBUSTION AIR ISSUE | | FOR THIS APPLIANCE NEEDS TO BE RESOLVED AND COMPLY. PER | | FBC-2004 FUEL GAS SECTION 304 COMBUSTION, VENTILATION | | AND DILLUTION AIR. | | | | 3. "OK" COMMENT ADDRESSED. | | | | **THE FOLLOWING ARE NEW COMMENTS** | | | | 4. SHEET A1.0 FIRST FLOOR PLAN INDICATES A GAS WATER | | HEATER IN A CLOSET OF THE MAIN HOUSE. THIS APPEARS TO | | BE A CONFINED SPACE, PLEASE SUBMIT COMBUSTION AIR | | CALCULATION AND SUBMIT MANUFACTURER'S SPECIFICATIONS | | FOR THE WATER HEATER. PER FBC-2004 FUEL GAS SECTION 304 | | COMBUSTION, VENTILATION AND DILLUTION AIR. | | | | 5. NOTICE: SEE ATTACHED NOTICE FS 553.80(2)(B) | | REGARDING FOUR (4) TIMES THE FEE. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-02-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-02-08 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-02-08 |
Time |
07:09 |
Sent To |
B |
|
Notes |
2008-02-08 08:34:40 | DENIED; | | 1. ADDRESS OF JOB ISREQUIRED ON ALLPAGES OF | | PLANS.FBC BUILDING CHAPTER 1 SECTION 106.1.1. | | 2. THE GAS WATER HEATER IN THE GUEST HOUSE GARAGE, SHOW | | HOW IT WILL BE VENTED TO THE OUTSIDE. PROVIDE | | MANUFACTURE'S SPECIFICATIONS. | | 3. THE RISER DIAGRAM DOES NOT MATCH THE FLOOR PLANS. | | A) BOTH 2ND FLOOR BATHROOMS HAVE 2-LAVATORYS | | B) MASTER BATH IS MISSING A TUB. | | C) BACK BATHROOM IS MISSING THE 2 LAVS. AND | | HAS AN EXTRA SHOWER. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-11-21 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2008-11-21 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2008-11-21 |
Time |
11:04 |
Sent To |
L |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-08-03 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2008-08-03 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2008-08-03 |
Time |
11:21 |
Sent To |
E |
|
Notes |
2008-08-03 11:22:28 | ***ZONING FAILED*** | | | | **REPEAT COMMENTS** | | | | 1.INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 2.PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDRS. | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDRS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR | | [email protected] | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-02-14 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-02-14 |
Time |
14:17 |
Sent To |
|
|
Notes |
2008-02-14 15:26:07 | ***FAILED*** | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM ALL NEW | | CONSTRUCTION TO ALL PROPERTY LINES.ALL NEW | | CONSTRUCTION SHALL COMPLY WITH CURRENT REGULATIONS. | | PURSUANT TO SECTION 94-74 OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDRS): | | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING. | | A.FRONT: 25 FEET; | | B.CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | FEET WIDE; | | C.REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER | | IS LESS; | | D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | THE SECOND FLOOR ADDITION AT THE REAR OF THE STRUCTURE | | DOES NOT MEET THE MINIMUM REQUIRED SETBACK OF 5' TO THE | | PROPERTY LINE.PLEASE REVISE. | | | | 2)INDICATE SETBACK DIMENSIONS FROM ANY PROPOSED OR | | RELOCATED A/C EQUIPMENT (IF ANY) TO ALL PROPERTY LINES. | | AS PER SECTION 94-305(B)(4) OF THE ZLDRS: MECHANICAL | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | REQUIRED SETBACK. | | | | 3)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE, | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE | | SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION | | 94-442 AND 94-445 OF THE ZLDRS. | | | | 4)INDICATE SEPARATION DISTANCE FROM EXISTING | | PRINCIPAL STRUCTURE TO THE PROPOSED GARAGE ADDITION. | | NOTE: MUST MAINTAIN A MINIMUM OF 6' SEPARATION. | | | | 5)INDICATE HEIGHT DIMENSIONS FROM GRADE TO THE | | MIDPOINT OF THE UPPERMOST ROOF'S PITCH.PURSUANT TO | | SECTION 94-74 OF THE ZLDRS:MAXIMUM HEIGHT FOR | | PRINCIPAL BUILDING = 30'.ALSO INDICATE HEIGHT | | DIMENSION OF THE CHIMNEY FROM GRADE TO THE UPPERMOST | | POINT OF THE CHIMNEY.CLARIFY IF CHIMNEY IS PROPOSED | | OR EXISTING, IF PROPOSED, THE CHIMNEY SHALL NOT EXCEED | | 33' IN HEIGHT MEASURED FROM GRADE. | | | | 6)INDICATE ALL OVERHANG DIMENSIONS, AND BALCONY | | DIMENSIONS FROM THE WALL TO THE OUTERMOST POINT. | | PURSUANT TO SECTION 94-305 OF THE ZLDRS:STRUCTURAL | | OVERHANGS, INCLUDING BUT NOT LIMITED TO BALCONIES, | | CORNICES, GUTTERS, EAVES, AND ROOF OVERHANG PROJECTIONS | | SHALL NOT EXTEND FARTHER THAN THREE FEET INTO ANY | | SETBACK. | | | | | | NOTE:ACCESSORY STRUCTURE SHALL NOT EXCEED 75 PERCENT | | OF THE GROSS FLOOR AREA OF THE PRIMARY STRUCTURE WITH A | | MAXIMUM FLOOR AREA OF 1,000 SQUARE FEET. | | | | NOTE:AS THERE ARE DIMENSIONALLY NONCONFORMING | | STRUCTURES ON THE LOT WITH RESPECT TO THE SETBACK | | REQUIREMENTS, NO NEW NONCONFORMITY SHALL BE CREATED AND | | NO EXISTING NONCONFORMITY SHALL BE INCREASED. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|