Plan Review Stops For Permit 08020013 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-13 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-13 |
Time |
16:08 |
Sent To |
|
|
Notes |
2008-03-13 16:08:56 | REVISION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-03-11 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-03-11 |
Time |
14:09 |
Sent To |
|
|
Notes |
2008-03-11 14:12:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.IT APPEARS THAT THE SCOPE OF THIS REVISION IS TO | | INCLUDE OPENINGS 8 AND 9, WHICH WERE REMOVED DUE TO THE | | SUBSTRATE NOT BEING INCLUDED IN THE PRODUCT APPROVAL. | | PLEASE REVISE THE FLOOR PLAN AND INSTALLATION SCHEDULE, | | AS THESE TWO OPENINGS WERE CROSSED OFF WHEN THE PERMIT | | WAS ISSUED.I ATTEMPTED TO DO THIS FOR YOU (SEE | | ATTACHED) BUT IT DOES NOT PROPERLY DOCUMENT THE WORK TO | | BE DONE FOR RECORD KEEPING PURPOSES. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-02-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-22 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-22 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-19 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-19 |
Time |
10:47 |
Sent To |
|
|
Notes |
2008-02-19 10:55:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.PLEASE REMOVE DOCUMENTS WHICH ARE NOT A PART OF THE | | PRODUCT APPROVAL.THIS REVIEW HAS BEEN DONE BASED ON | | THE MIAMIDADE NOA PROVIDED AS I CANNOT DETERMINE WHERE | | THE CUT SHEETS CAME FROM.WHEN I GO TO THE FLORIDA | | PRODUCT APPROVAL SITE, WWW.FLORIDABUILDING.ORG, IT | | APPEARS THAT MIAMIDADE NOAS WERE SUBMITTED.THEREFORE, | | COMPLIANCE WITH THIS PRODUCT APPROVAL IS REQUIRED | | UNLESS OTHER PAPERWORK IS SUBMITTED.AS DISCUSSED, THE | | INSTALLATION SCHEDULE SPECIFIES 2" GLASS SEPARATION; 2 | | 7/8 REQUIRED (SHEET SSHB C 050B). | | | | 2.DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS.THE ENGINEERING SUBMITTED ADDRESSED ONLY | | ANCHORING INTO THE EXISTING GLASS DOOR FRAME.NOTE | | THAT GLASS SEPARATION ALSO NEEDS TO BE ADDRESSED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-05 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-05 |
Time |
11:43 |
Sent To |
|
|
Notes |
2008-02-05 11:43:57 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED. | | | | _XX_4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | R310. | | | | _XZ_6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | ABOVE. | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-13 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-13 |
Time |
15:16 |
Sent To |
B |
|
Notes |
2008-03-13 15:17:04 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-06 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-06 |
Time |
11:25 |
Sent To |
B |
|
Notes |
2008-03-06 11:25:46 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-02-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-15 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-15 |
Time |
11:18 |
Sent To |
B |
|
Notes |
2008-02-15 11:18:32 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-02-05 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-02-01 |
Time |
14:28 |
Sent To |
|
|
Notes |
2008-02-01 14:28:48 | TO "MISC" BOX#1 |
|
|