Plan Review Details - Permit 08010762
Plan Review Stops For Permit 08010762 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-02-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-02-28 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-02-28 |
Time |
10:42 |
Sent To |
PC |
|
Notes |
2008-02-28 10:43:02 | DONNA FAXED NAIL ENHANCING LETTER. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-02-27 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-02-27 |
Time |
13:36 |
Sent To |
PC |
|
Notes |
2008-02-27 14:37:52 | COMMERCIAL ROOFING BUILDING REVIEW SECOND CHECKLIST: | | | | 1-FLAT ROOF SYSTEM NOA05-0830.10 SUBMITTED AND | | ENGINEER'S RAS 117 CALCULATIONS ARE FOR TWO DIFFERENT | | PRODUCTS.NOA 05-0830.10 IS A PRODUCT FROM FIRESTONE | | BUILDING PRODUCTS COMPANY, WHILE NOA 06-0410.06 | | REFERENCED BY THE ENGINEER IS A PRODUCT FROM POLYGLASS | | USA.NEED INFORMATION THAT MATCHES TO EACH OTHER. | | | | 2-ONLY TWO SETS OF ENGINEER CALCULATIONS WERE | | PROVIDED.THREE SETS OF EVERYTHING IS REQUIRED IN THIS | | JOB BECAUSE THERE IS A THRESHOLD INSPECTOR IN THIS | | JOB. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-31 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-31 |
Time |
15:42 |
Sent To |
PC |
|
Notes |
2008-01-31 16:12:43 | BUILDING REVIEW CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1-THIS IS A SEPARATE PERMIT AS AGREED ON WITH | | CONTRACTOR ON PROVISO DATED 04/12/07.SEE ATTACHED | | COPY. OWES $85.14FOR PERMIT FEE BALANCE. | | | | 2- SELECTED ASSEMBLY ON PAGE 31 OF NOA 05-0830.10 | | SUBMITTED CAN'T BE USED IN THIS AREA BECAUSE IT DOESN'T | | MEET THE DESIGN PRESSURES FOR PERIMETER AND CORNER | | AREAS AND ASSEMBLY IS LIMITED BY GENERAL LIMITATION #9, | | WHICH DOESN'T ALLOW NAIL ENHANCING.NEED TO SELECT | | ASSEMBLYTHAT IS LIMITED BY GENERAL LIMITATION #7, | | WHICH ALLOWS NAIL ENHANCING. | | | | 3- PROVIDE THE RAS 117 CALCULATIONS FOR NAIL ENHANCING | | AT PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | LIMITATION #7. | | | | 4- THERE IS A DESIGNER OF RECORD ON THIS PROJECT. | | DESIGNER OF RECORD NEEDS TO REVIEW AND APPROVE IN | | WRITING(NOT SIGNING AND SEALING)ALL PRODUCT | | APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS | | TO FBC 2004. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-26 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-26 |
Time |
14:47 |
Sent To |
B |
|
Notes |
2008-02-26 14:47:59 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-31 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-31 |
Time |
12:05 |
Sent To |
|
|
Notes |
2008-01-31 12:05:47 | TO "JGOMEZ" DESK/NEW ROOF |
|
|
|