Plan Review Details - Permit 08010729
Plan Review Stops For Permit 08010729 |
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-07-30 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-07-30 |
Time |
15:35 |
Sent To |
PC |
|
Notes |
2008-07-30 15:36:46 | REVISION: "OK" ADDED GAS PIPING TO FIRE PIT & VALUE | | INCREASED. | | | | ****************PROVISO**************** | | A} IF DRYER ROOM IS A CONFINED SPACE, OPENINGS | | REQUIRED PER SECTION 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | B} IF WATER HEATER ROOM IS A CONFINED SPACE, OPENINGS | | REQUIRED PER SECTION 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. MINIMUM 3,850 CUBIC FEET REQUIRED. | | | | C} PER FBC-2004 FUEL GAS, SECTION 409.4 MP REGULATOR | | VALVES: A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | IMMEDIATELY AHEAD OF EACH MP REGULATOR. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2008-01-31 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-31 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-31 |
Time |
14:59 |
Sent To |
PC |
|
Notes |
2008-01-31 15:01:55 | ****************PROVISO**************** | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | INGS REQUIRED PER SECTION 304.5 OR | | SECTION 304.6 SHALL BE INSTALLED. | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | IF WATER HEATER ROOM IS A CONFINED | | SPACE, OPENINGS REQUIRED PER SECTION | | 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. | | MINIMUM 3,850 CUBIC FEET REQUIRED. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-30 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-30 |
Time |
09:31 |
Sent To |
G |
|
Notes |
2008-07-30 09:31:50 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-31 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-31 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-30 |
Time |
12:45 |
Sent To |
|
|
Notes |
2008-01-30 12:45:33 | | | | | TO MIKE'S DESK./WRT. |
|
|
|