Plan Review Stops For Permit 08010413 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-29 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-29 |
Time |
09:48 |
Sent To |
|
|
Notes |
2009-05-29 09:49:57 | REVISION TO CHANGE SIZE OF THE B-4 BEAM IN BEAM | | SCHEDULE IS OK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-05-27 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-05-27 |
Time |
10:44 |
Sent To |
|
|
Notes |
2009-05-27 10:46:50 | SUBMITTED SIGNED AND SEALED 8.5" X 11" DETAIL OF | | REVISED DOOR AT COVERED PORCH #2 AS REQUESTED IN | | PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2009-04-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-04-09 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-04-09 |
Time |
09:38 |
Sent To |
|
|
Notes |
2009-04-09 09:46:14 | BUILDING PROVISO | | | | THE REVISION TO REPLACE THE NANAWALL FOLDING GLASS WALL | | W/FIXED GLASS TRANSOM ABOVE WITH THE WINDOOR SERIES | | 8000 SLIDING GLASS DOOR IS OKAY. CONTRACTOR IS TO | | SUBMIT TWO COPIES OF 8-1/2" X 11" SIGNED AND SEALED | | DRAWING OF THE NEW DOOR, SPECIFING THE OVERALL | | DIMENSIONS AND INDIVIDUAL PANEL SIZES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2009-01-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2009-01-27 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2009-01-27 |
Time |
13:22 |
Sent To |
|
|
Notes |
2009-01-27 13:30:35 | THE REVISION TO SIZE OF THE B-4 BEAM IS DENIED. THE B-2 | | BEAM ON THE REVISION HAS BEEN CHANGED FROM THE 8 X 30 | | BEAM SPECIFIED ON THE APPROVED PLANS, BUT HAS NOT BEEN | | CLOUDED ON THE REVISION TO INDICATE THAT IT WAS | | CHANGED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-08-02 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-08-02 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-08-02 |
Time |
09:21 |
Sent To |
Z |
|
Notes |
2008-08-02 09:23:30 | | | | | PASSED | | | | ROUTED BACK TO LUIS FOR ZONING REVIEW, REQUIRES DATE | | STAMP UPON ZONING APPROVAL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-05-22 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-05-22 |
Time |
17:49 |
Sent To |
PC |
|
Notes |
2008-05-22 18:28:01 | | | | | | | DENIED | | | | THE FOLLOWING COMMENT FROM THE 1STREVIEW WERE NOT | | ADDRESSED: | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMITSETS OF PLANS MUST BE STAMPED BY THAT OFFICE, | | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES. THE BALANCE DUE | | FOR RADON IS $24.22 | | | | 7)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. *******ARE THE SMOKE ALARMS EXISTING | | AND HARD WIRED, PLEASE CLARIFY******* | | | | 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | ********NO SUBMITTED PRODUCT APPROVALS HAVE BEEN | | REVIEWED AND APPROVED BY THE DESIGNER OF RECORD****** | | | | 12)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. | | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. | | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | DENIED ******NOTE FLORIDA APPROVAL NUMBERS ARE WRITTEN | | AT TOP OF NOA'S******* | | | | ********FLORIDA STATEWIDE PRODUCT APPROVAL SHEETS WERE | | NOT PROVIDED********** | | | | 13)NO PRODUCT APPROVALS WERE SUBMITTED FOR NANA WALL | | SYSTEM. ******** THE SL70 THAT IS SPECIFIED ON SHEET | | A-1 IS A FOLDING DOOR SYSTEM IN AN EXTERIOR WALL AND AS | | SUCH CONSIDERED PART OF THE COMPONENTS AND CLADDING OF | | THE BUILDING. THEY ARE ALSO SUBJECT TO MIN DESIGN | | PRESSURES BASED ON LOCATION AND SQUARE FOOTAGE OF WALL | | AREA, THEREFORE PRODUCT APPROVALS ARE REQUIRED. PLEASE | | FIND UNDER FLORIDA STATEWIDE APPROVAL NUMBER FL6859-R1 | | WITH THE COMPLIANCE REPORTS FOR DOOR TYPE. NOTE THIS | | MODEL IS LARGE MISSILE IMPACT RATED********** | | | | 14)ALL WINDOW OPENINGS AND CONFIGURATIONS FOR | | ALTERNATE #1 SHALL BE LISTED AND APPROPRIATE PRODUCT | | APPROVALS SUBMITTED FOR WORK TO BE INCLUDED IN THIS | | PERMIT********PROVIDE FLORIDA STATEWIDE APPROVAL FL # | | 9066-R1 WITH COMPLIANCE REPORT MIAMI-DADE NOA # | | 08-8304.08 WHICH REVISES THE REPORT THAT WAS SUBMITTED | | WERE NOT SUBMITTED********* | | | | 16)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | AMENDMENTS | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | AMENDMENTS TO FBC | | FAC = FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | FBC RES. = FLORIDA BUILDING CODE | | RESIDENTIAL 2004 W/2006 & 2007 AMENDMENTS | | | | REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF | | NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE | | OLD PAGES ONLY FOR REFERENCE. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-01-22 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-01-22 |
Time |
17:49 |
Sent To |
E |
|
Notes |
2008-01-22 18:58:33 | | | | | DENIED | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMITSETS OF PLANS MUST BE STAMPED BY THAT OFFICE, | | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | ADDED TO THE PERMIT APPLICATION FEES. THE BALANCE DUE | | FOR RADON IS $24.22 | | | | 3)A DESIGN PROFESSIONAL THAT IS REGISTERED TO | | PRACTICE UNDER CHAPTER 481 OR 471 OF THE FLORIDA | | STATUTES SHALL AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND | | DATE TO SAID DRAWINGS AND SPECIFICATIONS PER 106.1 FBC | | 2004. ****PLEASE NOTE THAT SIGNATURES WERE NOT DATED ON | | THE ARCHITECTURAL SHEETS***** | | | | 4)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD | | | | 5)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS | | REQUIRED PER R807.1 FBC RES. MINIMUM ROUGH OPENING 22" | | X 30" | | | | 6)BUILDING ELEVATIONS TO INCLUDE MEAN ROOF HEIGHT | | | | 7)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | R313.1.1 FBC RES. | | | | 8)PROVIDE AT MINIMUM 1 ACCESSIBLE BATHROOM PER | | R322.1.1 FBC 29" CLEAR WITH DOOR OPEN 90 DEGREES REMOVE | | ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF NEW | | DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE OLD | | PAGES ONLY FOR REFERENCE | | | | 9)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER | | R803.2.3.1 FBC RES. MINIMUM 8D RING SHANK NAILS 6" O/C | | IN ZONES 1 & 2 AND 4" O/C IN ZONE 3 | | | | 10)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | *****APPLIES TO MISSING PRODUCT APPROVALS***** | | | | 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | *****APPLIES TO MISSING PRODUCT APPROVALS***** | | | | 12)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. | | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. | | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE | | DENIED ******NOTE FLORIDA APPROVAL NUMBERS ARE WRITTEN | | AT TOP OF NOA'S***** | | | | 13)NO PRODUCT APPROVALS WERE SUBMITTED FOR NANA WALL | | SYSTEM, IMPACT ENTRY DOOR, VINYL SOFFIT, CASTCRETE | | LINTELS, AND SIMPSON TIE CONNECTORS AND STRAPS. IN LUE | | OF PRODUCT APPROVALS STRAP/CONNECTOR FLORIDA APPROVAL | | NUMBERS MAY BE LISTED IN THE SCHEDULE ON THE DRAWINGS | | OR SUBMIT SIMPSON TIE'S COMPLETE FLORIDA INDEX WITH | | CONNECTORS TO BE USED HIGHLIGHTED | | | | 14)ALL WINDOW OPENINGS AND CONFIGURATIONS FOR | | ALTERNATE #1 SHALL BE LISTED AND APPROPRIATE PRODUCT | | APPROVALS SUBMITTED FOR WORK TO BE INCLUDED IN THIS | | PERMIT | | | | 15)ALTERNATE #4,BLOCK FENCE/SCREEN WALL ON THE | | PROPERTY LINE REQUIRES AN EASEMENT RELEASE FROM THE | | CITY OF WEST PALM BEACH UTILITIES DEPT. | | | | 16)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | AMENDMENTS | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | AMENDMENTS TO FBC | | FAC = FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | FBC RES. = FLORIDA BUILDING CODE | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF | | NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE | | OLD PAGES ONLY FOR REFERENCE. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-27 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-27 |
Time |
08:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-07-29 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-07-29 |
Time |
08:04 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-05-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-05-19 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-05-19 |
Time |
12:07 |
Sent To |
M |
|
Notes |
2008-05-19 12:07:42 | ** DENIED** | | | | 1) NOTE: PLEASE SEE THE PREVIOUS REVIEW NOTE WHICH | | REQUESTED THE MANUFACTURES SPECS/CUT SHEETS FOR THE NEW | | PROPOSED ATS TO BE SUBMITTED. THIS WAS INDEED DONE | | HOWEVER THE SUBMITTAL SPECS/CUT SHEETS DO NOT CORRELATE | | WITH THE SUBMITTED INFORMATION ON PLANS. THE PLANS CALL | | FOR SEPARATE EQUIPMENT, DIFFERENT MANUFACTURE ETC. | | 90.7, 110.9, 110.3 ETC. | | FBC 106.1.2. | | PLEASE KNOW AT THIS TIME WITH NO INSTALLATION OF A | | GENERATOR NO VIOLATION EXISTS HOWEVER PLEASE KNOW A | | DISCONNECTING MEANS FOR THE GENERATOR FEEDERS MAY BE | | REQUIRED AT THE FUTURE DATE. 225.34. | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #5. PLANS NOW | | SHOW SMOKE DETECTORS HOWEVER NO HORN, STROBE DEVICES, | | OR OTHER LOW VOLTAGE FIRE ALARM DEVICES OR SYSTEMS ARE | | SHOWN. | | PLEASE SEE NFPA-72 AS THE DEFINITION OF A SMOKE | | DETECTOR IS ONLY A DEVICE WHICH *DETECTS* AND DOES NOT | | SOUND ANY ALARM. PLEASE SEE THE SAME CODE FOR | | DEFINITION OF *SMOKE ALARMS*.SMOKE ALARMS ARE DEVICES | | WHICH *DETECT* AND *SOUND* AN ALARM. | | ARE THESE DEVICES NOT SMOKE ALARMS? | | PLEASE SEE R313, 11.5.1.1, 11.8.3 NFPA-72 2003. | | PLEASE INDICATE IF NEW TO BE INSTALLED OR ALREADY | | EXISTING. | | | | 3) NOTE: PLEASE SEE THE LOADS ON THE SERVICE ARE | | REQUIRED TO BE FIGURED PER 220.83B. | | | | 4) NOTE: PLEASE SEE THE CU#2 IS BEING FED FROM NEW | | PANEL B YET THE AHU IS BEING FROM EXISTING PANEL *A*. | | WHEN UNDER FUTURE GENERATOR POWER ONLY HALF OF THIS | | SYSTEM WOULD BE UNDER POWER BEING FED FROM TWO | | SOURCES. | | ** THIS IS GIVEN AS INFORMATION ONLY HOWEVER MAY WANT | | TO REVISE AT THIS TIME. | | | | ** PLANS ARE COMING BACKFOR OTHER CORRECTIONS, PLEASE | | ADDRESS COMMENTS 1-3. | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-01-23 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-01-23 |
Time |
15:33 |
Sent To |
M |
|
Notes |
2008-01-23 15:33:55 | | | | | ** DENIEDREVIEW ** | | | | 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | PLEASE SEE THAT THIS SHALL INCLUDE 2007 REVISIONS TO | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | AFFECT DESIGNS FOR ALL TRADES. | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2007 REVISIONS | | 2005 NFPA-70 | | 2002 NFPA-72 | | | | ** PLANS SHOW THE 1999 NFPA-70 AND A 2004 NFPA/LS 101 | | WHICH DOES NOT EXIST. PLEASE ADJUST. | | PLEASE ALSO INCLUDE THE ABOVE RELEVANT CODES ON | | ELECTRICAL PLANS. | | | | 2) NOTE: PLEASE SUBMIT THE RELEVANT MANUFACTURES | | SPECS/CUT SHEETS FOR THE NEW PROPOSED GENERATOR AND | | TRANSFER SWITCH. | | PLEASE BE SURE THE MANUFACTURES SPECS/CUT SHEETS | | CONTAIN ALL THE MINIMUM CLEARANCE REQUIREMENTS. 110.3, | | 90.7. | | FBC ADMIN SECTION 106.1.2 | | | | 3) NOTE: PLEASE INDICATE IF THE GENERATOR WILL BE A | | SEPARATELY DERIVED SYSTEM. PLEASE SEE | | 250.20,250.66,250.30 ETC. | | PLEASE KNOW KOHLER AS STATED ON PLANS COME SHIPPED AS | | SD AND WILL REQUIRE REMOVAL OF BONDING JUMPER IF THIS | | IS NOT GOING TO BE SD. | | | | 4) NOTE: PLEASE SEE 110.26 FOR MINIMUM CLEARANCES FOR | | CU #2 AND #3, DISCONNECTS. | | | | 5) NOTE: PLEASE SEE FBC R313 FOR REQUIRED NEW OR | | EXISTING SMOKE ALARMS IN THE EXISTING DWELLING MEETING | | CURRENT NFPA-72 11.5.1.1, AND 11.8.3. | | PLEASE SHOW LAYOUT OF ALL NEW TO BE INSTALLED OR | | EXISTING MEETING CURRENT CODES. | | | | 6) NOTE: PLEASE KNOW AS FOR INFORMATIONAL PURPOSE, THE | | POOL SCOPE OF WORK WILL BE REQUIRED TO BE UNDER A | | SEPARATE PERMIT. | | 106.1 | | | | 7) NOTE: PLEASE CLARIFY HEATING SYSTEMS. LOAD | | CALCULATIONS INDICATE *SPACE HEATERS* HOWEVER SHOULD | | THESE NO BE HEAT-STRIPS? SPACE HEATERS BY DEFINITION | | ARE NOT THE SAME AS CENTRAL HEAT. | | PLEASE ADJUST. | | FBC 106.3.5.4, NEC 424, 422 | | | | 8) NOTE: PLEASE SEE MISSING RECEPTACLE(S) PER 210.52, | | 210.52H FOR FOYER/HALL AREA. PLEASE ALSO VERIFY WALL AT | | WHAT APPEARS TO BE HALL AREA #2 ON WALL SPACE ON THE | | BACK/UNDERSIDE OF COUNTER SPACE. | | | | 9) NOTE: PLEASE SEE 410.8 FOR MINIMUM CLEARANCES FOR | | LIGHTING FIXTURES. THE TYPE OF FIXTURE NEEDS TO BE | | RELOCATED OR ADJUST TYPE OF FIXTURE. | | | | 10) NOTE: PLEASE SEE 408.4 AS THE PANEL SCHEDULE(S) FOR | | NEW CIRCUITS ARE TO BE SPECIFIC TO ROOMS AND AREAS IN | | WHICH THEY FEED. PLEASE SEE THE FOLLOWING TEXT WHICH IS | | TAKEN FROM THE CODE COMMENTARY. | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANELBOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION.* | | AS THE PANEL SCHEDULE MENTIONS GEN LTS AND RECEPTS IN | | MANY LOCATIONS, THESE WOULD BE FOR EXAMPLE: MEDIA ROOM, | | DINING RM LTS, DINING RM RECEPTS ETC. | | IT IS KNOWN TO THIS OFFICE THIS WILL BE REVISED BEFORE | | FINAL. | | FBC 106.1.2, 106.3.5.4, | | | | 11) NOTE: PLEASE SEE FOUNTAIN LOCATION AT REAR OF | | DWELLING WHICH IS SWITCHED FROM INSIDE DOES NOT SHOW | | ANY GFI PROTECTION AS REQUIRED PER 210.8A3, 680.56 | | | | 12) NOTE: PLEASE SEE RISER IS MISSING EQUIPMENT | | GROUNDING CONDUCTORS FROM ALL LOCATIONS AFTER THE FIRST | | MEANS OF DISCONNECT PER 250.110, 250.24, 250.6, 250.122 | | ETC | | | | 13) NOTE: PLEASE SEE MISSING DISCONNECTING MEANS FOR | | FEEDERS FROM GENERATOR TO DWELLING. | | PLEASE SEE 225.31-225.39. PLEASE ALSO SEE 702.11 AS THE | | EXCEPTION OF THE DISCONNECTING MEANSMSUT MEET ALL | | REQUIREMENTS. | | | | 14) NOTE: PLEASE SEE GROUNDING ELECTRODE SYSTEM IS | | SHOWING #4 AWG FOR GROUNDING ELECTRODE CONDUCTOR BEING | | PARALLELED WHICH IS NOT PERMITTED. PLEASE SEE 250.66 | | FOR SIZING OF THE GROUNDING ELECTRODE CONDUCTOR. PLEASE | | SEE THE RISER ALSO SHOW *STRUCTURAL STEEL* AS PART OF | | THE GROUNDING ELECTRODE SYSTEM. STRUCTURAL STEEL WHERE | | PRESENT IS REQUIRED PER 250.50, HOWEVER PLEASE SEE | | 250.50 AS FOOTER STEEL (NEW) IS ALSO REQUIRED. | | PLEASE ADJUST AND INCLUDE ON RISER. | | | | 15) NOTE: PLEASE SEE THE SERVICE IS BEING SHOWN AS | | 400AMPS YET THE METER CAN IS ONLY SHOWN AS 300AMPS. IS | | THIS A TRUE 300AMP METER CAN? | | PLEASE VERIFY AND ADJUST AS ALL SERVICE EQUIPMENT SHALL | | BE RATED FOR SIZING OF SERVICE. | | 110.3, 90.7, 230, ETC | | | | 16) NOTE: PLEASE VERIFY CIRCUITING FOR DINING ROOM | | RECEPTACLES PER 210.52B1, 210.11C1 AND 220.53. PLEASE | | SEE LOAD CALCULATIONS INDICATE 3-SMALL APPLIANCE | | CIRCUITS YET THE PANEL SCHEDULES ONLY SHOWS 2. PLEASE | | CLARIFY IF THIS OTHER CIRCUIT AS SHOWN IS THE DINING | | ROOM. | | | | 17) NOTE: PLEASE VERIFY THE KW RATING OF THE GENERATOR. | | THE UNIT IS 30KW ON RISER AND 27KW IN NOTES. | | FBC 106.1.2 FOR COORDINATION. | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | CONTACTING THIS REVIEWER. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-05-20 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-20 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2008-05-20 10:51:44 | NOTE: GAS PIPING DESIGN TO BE SUBMITTED AND PERMITTED | | SEPERATELY. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-28 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-28 |
Time |
13:35 |
Sent To |
|
|
Notes |
2008-01-28 14:34:08 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | GAS PLAN REVIEW: | | DENIED: | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET P-3 NATURAL GAS PIPING RISER: | | SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE SECTION *401.1 SCOPE. | | *THE GAS PIPING RISER DOES NOT INDICATE CORRESPONDING | | LENGTHS TO ALL CUT SECTIONS OF PIPE. REFERENCE THE RED | | CIRCLED CUT SECTIONS THAT ARE HIGH LIGHTED YELLOW. | | | | 2. SHEET P-3 NATURAL GAS PIPING RISER: | | SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. PER FBC FUEL GAS | | SECTION *401.1 SCOPE. | | *THE GAS PIPING RISER DOES NOT INDICATE THE TYPE OF | | PIPING MATERIAL BEING USED. | | | | 3. SHEET P-3 NATURAL GAS PIPING RISER: | | SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | * THE ADDED SUM OF THE INDICATED CORRESPONDING LENGTHS | | TO CUT SECTIONS OF PIPING EQUALS 151', HOWEVER NOTES: | | 3) DISTANCE IS INDICATING 185'. PLANS AT A MINIMUM | | SHALL BE CORRELATED. PER FBC FUEL GAS SECTION *401.1 | | SCOPE. | | | | 4. SHEET P-3 NATURAL GAS PIPING RISER: | | INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | * NOTES: 4) DELIVERY PRESSURE PRESSURE IS BEING | | INDICATED AS 0.8 PSI. THIS INDICATED DELIVERY PRESSURE | | IS WRONG FOR NATURAL GAS. FLORIDA PUBLIC UTILTIES CO. | | HAS 0.5, 2 OR 5 PSI DELIVERY PRESSURE. | | | | 5. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2. | | *PLEASE SUBMIT TWO COPIES OF MANUFACTURER | | SPECIFICATIONS ON THE PROPOSED GENERATOR INDICATING THE | | MAKE, MODEL NUMBER, BTU LOAD CAPACITY, AND A LISTING | | FROM A NATIONALLY RECOGNIZED TESTING LABORATORY AS WELL | | AS INDICATING THE MANUFACTURER SETBACK RECOMMENDATIONS | | FROM STRUCTURES. | | | | 6. SUBMIT TWO COPIES OF A SITE PLAN OR SURVEY CLEARLY | | INDICATING THE LOCATION OF THE PROPOSED GENERATOR | | INDICATING A DIMENTIONS FROM PROPERTY LINES AND | | DISTANCES FROM STRUCTURES. (ZONING APPROVAL REQUIRED | | FOR PROPOSED GENERATOR LOCATION PRIOR TO GAS PERMIT | | BEING ISSUED) PER FBC FUEL GAS SECTION *401.1 SCOPE | | | | 7. SHEET P-1 GAS PLAN IS CLEARLY INDICATING WHERE THE | | UNDERGROUND GAS PIPING IS BENEATH THE PROPOSED | | BUILDING. PER FBC FUEL GAS SECTION *404.11 PIPING | | UNDERGROUND BENEATH BUILDINGS. | | PIPING INSTALLED UNDERGROUND BENEATH BUILDINGS IS | | PROHIBITED EXCEPT WHERE THE PIPING IS ENCASED IN A | | CONDUIT OF WROUGHT IRON, PLASTIC PIPE OR STEEL PIPE | | DESIGNED TO WITHSTAND THE SUPERIMPOSED LOADS. SUCH | | CONDUIT SHALL EXTEND INTO AN OCCUPIABLE PORTION OF THE | | BUILDING AND, AT THE POINT WHERE THE CONDUIT TERMINATES | | IN THE BUILDING, THE SPACE BETWEEN THE CONDUIT AND THE | | GAS PIPING SHALL BE SEALED TO PREVENT THE POSSIBLE | | ENTRANCE OF ANY GAS LEAKAGE. WHERE THE END SEALING IS | | CAPABLE OF WITHSTANDING THE FULL PRESSURE OF THE GAS | | PIPE, THE CONDUIT SHALL BE DESIGNED FOR THE SAME | | PRESSURE AS THE PIPE. SUCH CONDUIT SHALL EXTEND NOT | | LESS THAN 4 INCHES (102 MM) OUTSIDE THE BUILDING, SHALL | | BE VENTED ABOVE GRADE TO THE OUTDOORS AND SHALL BE | | INSTALLED SO AS TO PREVENT THE ENTRANCE OF WATER AND | | INSECTS. THE CONDUIT SHALL BE PROTECTED FROM CORROSION | | IN ACCORDANCE WITH SECTION 404.8 . CLEARLY INDICATE | | THIS REQUIREMENT ON THE RESUBMITTAL. PER FBC FUEL GAS | | SECTION *401.1 SCOPE. | | | | 8. SHEET P-3 NATURAL GAS PIPING RISER: NOTES: 1) | | INDICATES THE FOLLOWING "CONTRACTOR TO SUBMIT A PROPER | | GAS PIPING LAYOUT WITH PERMIT APPLICATION". BY THE | | INDICATION OF THIS NOTE, IS IT THE INTENT TO HAVE THE | | PLUMBING OR GAS CONTRACTOR TO SUBMIT THEIR OWN DESIGN | | AT THE TIME OF THE GAS PERMIT APPLICATION? IF THAT IS | | THE INTENT PLEASE REMOVE ALL GAS PIPING DESIGN FROM | | SHEETS P-1 AND P-3 AS WELL AS THE PROPOSED GENERATOR | | AND CLEARLY INDICATE THE GENERATOR AS "FUTURE". PER | | CITY WPB AMENDMENTS SECTION *106.1.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS AND SECTION *401.1 SCOPE. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2009-05-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-05-27 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-05-27 |
Time |
16:40 |
Sent To |
|
|
Notes |
2009-05-28 16:41:42 | BEAM REVISION, GAVE TO MCDOUGL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2009-05-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-05-21 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-05-21 |
Time |
11:56 |
Sent To |
B |
|
Notes |
2009-05-21 11:56:57 | TO RMCD DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-15 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-15 |
Time |
15:37 |
Sent To |
M |
|
Notes |
2009-05-15 15:37:55 | TO MECH BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2009-05-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2009-05-15 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2009-05-15 |
Time |
15:30 |
Sent To |
E |
|
Notes |
2009-05-21 10:50:28 | THIS REV IS NOT TO D PALMER, THIS IS TO BILL T DESK. | 2009-05-15 15:31:34 | REV SENT TO D PALMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2009-04-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-04-08 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-04-08 |
Time |
11:29 |
Sent To |
B |
|
Notes |
2009-04-08 11:29:36 | TO "RMCDOUGAL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-01-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-14 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-14 |
Time |
16:07 |
Sent To |
B |
|
Notes |
2009-01-14 16:07:57 | TO "LMARTINEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-17 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-17 |
Time |
14:09 |
Sent To |
Z |
|
Notes |
2008-07-17 14:10:08 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-05-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-13 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-13 |
Time |
10:28 |
Sent To |
Z |
|
Notes |
2008-05-13 10:30:13 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-28 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-18 |
Time |
11:37 |
Sent To |
|
|
Notes |
2008-01-18 11:37:15 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-05-29 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-05-29 |
Time |
11:50 |
Sent To |
PC |
|
Notes |
2009-05-29 11:51:03 | PAGE M1 REVISION 3 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-20 |
Time |
08:32 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-05-20 |
Time |
08:32 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-01-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-24 |
Time |
10:33 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2008-01-24 |
Time |
10:33 |
Sent To |
P |
|
Notes |
2008-01-24 10:38:40 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | 1) RETURN AIR MAY NOT BE TAKEN FROM THE KITCHEN, SEE | | 2004 FBC/R M1602.2 (4). PLEASE CORRECT. | | | | 2) PLEASE SHOW ON THE MECHANICAL PLAN PAGE M-1 THE GAS | | BBQ GRILL AND EXHAUST HOOD LOCATED IN PORCH #2, SEE | | 2004 FBC/R M1504.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-05-20 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-05-20 |
Time |
10:43 |
Sent To |
G |
|
Notes |
2008-05-20 10:47:58 | ****************PROVISO**************** | | (A) 604.9 WATER HAMMER. A WATER-HAMMER | | ARRESTOR SHALL BE INSTALLED WHERE | | QUICK-CLOSING VALVES ARE UTILIZED. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-28 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-28 |
Time |
10:07 |
Sent To |
PC |
|
Notes |
2008-01-28 10:43:28 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | DENIED: | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | 1. SHEET A-1 IS INDICATING THE APPLICABLE CODE WRONG | | PLEASE CORRECT THE AMENDMENTS FROM 2006 TO 2007 | | REVISIONS. PER FBC PERMIT APPLICATIONS SUBMITTED AFTER | | 12/8/06. | | | | 2. SHEET P-1 IS INDICATING WH-1 IN THE NEW GARAGE: | | PLEASE INDICATE HOW THE WATER HEATER WILL BE PROTECTED | | FROM VEHICLE DAMAGE BY APPROVED BARRIERS. PER FBC | | MECHANICLA SECTION * 304.4. | | | | 3. SHEET P-1 IS INDICATING "EXISTING SANITARY LINE TO | | BE CAPPED OFF @ EXISTING SINK". PER FBC PLUMBING | | SECTION *704.5 DEAD ENDS. | | IN THE INSTALLATION OR REMOVAL OF ANY PART OF A | | DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | CLEANOUT EXTENSIONS AND APPROVED FUTURE FIXTURE | | DRAINAGE PIPING SHALL NOT BE CONSIDERED AS DEAD ENDS. | | | | 4. SHEET P-1 AND P-2 INDICATE THE REQUIRED TWO-WAY | | CLEANOUTS PER FBC PLUMBING SECTION 708.3.5 BUILDING | | DRAIN AND BUILDING SEWER JUNCTION. | | | | 5. SHEET P-1 PLEASE INDICATE THE LOCATION OF THE | | REQUIRED (EXISTING OR NEW), 1 AUTOMATIC CLOTHES WASHER | | CONNECTION. PER FBC PLUMBING TABLE 403.1 (R-3) ONE AND | | TWO FAMILY DWELLINGS. | | | | 6. NOTE: PLEASE KNOW AS FOR INFORMATIONAL PURPOSES, | | THE POOL/SPA SCOPE OF WORK WILL BE REQUIRED TO BE UNDER | | A SEPERATE PERMIT 106.1. | | | | ********IMPORTANT INFORMATION******** | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | EXAMINER FOR REFERENCE FOR THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | PHONE= (561) 805-6730 | | FAX= (561) 805-6731 | | E-MAIL= [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-08-11 |
|
|
Cont ID |
|
Sent By |
bpowell |
Date |
2008-08-11 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
bpowell |
Date |
2008-08-11 |
Time |
13:51 |
Sent To |
|
|
Notes |
2008-08-11 13:54:00 | 1.THE PAVERS THAT ARE PROVIDED AS THE DRIVEWAY ARE | | NOT ALLOWED TO BE SEALED AND SHALL BE SET IN SAND. | | | | IF YOU HAVE ANY QUESTIONS OR COMMENTS CONTACT: BOBBY | | POWELL JR., [email protected], (561) 822-1449 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2008-05-14 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-14 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-14 |
Time |
13:39 |
Sent To |
E |
|
Notes |
2008-05-14 13:40:37 | ***FAILED - RESUB #1*** | | | | | | REPEAT COMMENTS: | | | | 1) REMOVAL/ALTERATION OF LANDSCAPING WILL REQUIRE A | | TREE ALTERATION PERMIT FROM THE CITY'S PLANNING AND | | ZONING DEPARTMENT.SEE LANDSCAPE PLANNER, ROBERT | | KUSSNER, 561-822-1435.ROBERT REPORTS NO RECORD OF A | | TREE ALTERATION PERMIT FOR THIS PROPERTY. | | | | 3) THE PROVIDED SITE PLAN CONTAINS A NEW VINYL | | COATED C/L FENCE TO BE INSTALLED AT THE EAST SIDE OF | | THE PROPERTY, THIS FENCE IS NOT INCLUDED UNDER THE | | CURRENT APPROVAL FROM THE CITY'S DEPARTMENT OF PUBLIC | | UTILITIES.AN APPROVED EASEMENT CONSENT FORM FROM THE | | CITY OF WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES | | (1ST FLOOR CITY HALL) IS REQUIRED FOR ALL PROPOSED | | FENCES/WALLS. | | | | | | NOTE:A RIGHT-OF-WAY PERMIT SHALL BE REQUIRED FOR THE | | PROPOSED APPROACH, SEE ENGINEERING DEPARTMENT, WINDEL | | PALMER, 561-494-1040. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | SENT TO "E" - DP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-01-22 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-01-22 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-01-22 |
Time |
11:09 |
Sent To |
B |
|
Notes |
2008-01-22 11:15:11 | ***FAILED*** | | | | | | 1)REMOVAL/ALTERATION OF LANDSCAPING WILL REQUIRE A | | TREE ALTERATION PERMIT FROM THE CITY'S PLANNING AND | | ZONING DEPARTMENT.SEE LANDSCAPE PLANNER, ROBERT | | KUSSNER, 561-822-1435. | | | | 2)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE, | | LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.SITE | | PLAN SHOWS REMOVAL OF LANDSCAPING, HOWEVER, A LANDSCAPE | | PLAN SHOWING COMPLIANCE WITH SECTION 94-442 AND 94-445 | | OF THE ZLDRS MUST BE SUBMITTED. | | | | 3)AN APPROVED EASEMENT CONSENT FORM FROM THE CITY OF | | WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (1ST | | FLOOR CITY HALL) IS REQUIRED FOR ALL PROPOSED | | FENCES/WALLS. | | | | 4)INDICATE CHIMNEY PROTRUSION FROM REAR WALL OF | | STRUCTURE.PURSUANT TO SECTION 94-305 OF THE ZLDRS: | | CHIMNEYS MAY PROJECT NO MORE THAN 18" INTO A REQUIRED | | SETBACK. | | | | 5)INDICATE ALL ROOF OVERHANG DIMENSIONS.PURSUANT | | TO SECTION 94-305 OF THE ZLDRS:ROOF OVERHANGS MAY NOT | | PROJECT MORE THAN 3' INTO A REQUIRED SETBACK. | | | | 6)INDICATE HEIGHT DIMENSIONS FROM GRADE TO THE | | UPPERMOST POINT OF THE PROPOSED CHIMNEY. | | | | | | NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT | | TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | ZONING TECHNICIAN (561)805-6720 |
|
|