Plan Review Details - Permit 08010311
Plan Review Stops For Permit 08010311 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-04-22 |
Time |
07:59 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2008-04-22 |
Time |
07:59 |
Sent To |
|
|
Notes |
2008-04-22 08:01:07 | BUILDING PLAN REVIEW | | PERMIT: 08010311 | | ADD: 1335 OKEECHOBEE RD SUITE# 1000 | | CONT: PCF CONSTRUCTION | | TEL: (561)346-8281 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 2NDREVIEW | | ACTION: DENIED | | | | NOTE NOT ONE COMMENT WAS ADDRESSED!!! | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | REVIEW FOR PERMIT. | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | ADMINISTRATIVE CODE. | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS | | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE2007 SUPPLEMENTS PLEASE INDICATE AS | | SUCH. | | | | 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | OF OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | DESIGNED. | | B) 2004 FL BUILDING CODE, EXISTING BUILDING, ADDING A | | MEZANINE CONSTITUTES AN ADDITION SEE ASSOCIATED | | CHAPTERFOR ADDITIONS. | | C) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION (FOR THE EXISTING BUILDING) | | AS DEFINEDIN CHAPTER 6, TABLE 601. | | D) THE OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F) | | WHETHER THE SPRINKLER SYSTEM IS REQUIRED, (AREA | | INCREASES). | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | BUILDING PERMIT | | H) ) NUMBER OF UNITS | | I ) NUMBER OF FLOORS | | J ) SQ. FT.OF BUILDING / PER FL | | J ) SQ. FT. FOOTPRINT | | | | 3)UNTIL USE AND OCCUPANCY IS PROVIDED, VERTICAL | | ACCESSIBILITY MAY OR MAY NOT BE A ISSUE THAT MAY NEED | | TO BE ADDRESSED.11-4.1.6(1)(K)(III). | | | | 4)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | NOTE: A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | ON REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE | | NOT PART OF THIS REVIEW. | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | APPLICABLE. | | | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-01-26 |
Time |
14:41 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2008-01-26 |
Time |
14:41 |
Sent To |
|
|
Notes |
2008-01-26 14:55:18 | BUILDING PLAN REVIEW | | PERMIT: 08010311 | | ADD: 1335 OKEECHOBEE RD SUITE# 1000 | | CONT: PCF CONSTRUCTION | | TEL: (561)346-8281 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1A) --- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, | | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR | | REVIEW FOR PERMIT. | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | /2004 SUBMITTAL DOCUMENTS WEST PALM BEACH | | ADMINISTRATIVE CODE. | | | | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 DRAWINGS & | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO | | THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR | | IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED | | AS A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION | | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND | | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS | | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | | | 1D ) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE 2007 SUPPLEMENTS PLEASE INDICATE AS | | SUCH. | | | | 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | OF OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | DESIGNED. | | B) 2004 FL BUILDING CODE, EXISTING BUILDING, ADDING A | | MEZANINE CONSTITUTES AN ADDITION SEE ASSOCIATED | | CHAPTERFOR ADDITIONS. | | C) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION (FOR THE EXISTING BUILDING) | | AS DEFINED IN CHAPTER 6, TABLE 601. | | D) THE OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED F) | | WHETHER THE SPRINKLER SYSTEM IS REQUIRED, (AREA | | INCREASES). | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | BUILDING PERMIT | | H) ) NUMBER OF UNITS | | I ) NUMBER OF FLOORS | | J ) SQ. FT.OF BUILDING / PER FL | | J ) SQ. FT. FOOTPRINT | | | | 3) UNTIL USE AND OCCUPANCY IS PROVIDED, VERTICAL | | ACCESSIBILITY MAY OR MAY NOT BE A ISSUE THAT MAY NEED | | TO BE ADDRESSED.11-4.1.6(1)(K)(III). | | | | 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | NOTE: A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, | | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | THIS REVIEW. | | ON REQUESTED ADDITIONAL COMMENTS MAY APPEAR THAT WERE | | NOT PART OF THIS REVIEW. | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | APPLICABLE. | | | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2008-04-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-04-03 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-04-03 |
Time |
15:02 |
Sent To |
|
|
Notes |
2008-04-03 15:03:00 | ** DENIED 2ND REVIEW ** | | | | 1) NOTE: PLEASE SEE COMMENTS FROM PREVIOUS REVIEW AS | | THE SAME COMMENTS APPLY. | | IF AN OCCUPANT ON THE MEZZANINE LEVEL AND LIGHTS TURN | | OFF, HOW WILL THE OCCUPANT HAVE CONTROLS FOR EGRESS | | LIGHTING FOR MINIMUM LIGHTING LEVELS? | | PLEASE SEE THE NOTES AS PREVIOUSLY MENTIONED STILL | | APPLY. MAY NOT ADD NEW MEZZANINE LEVEL WITHOUT | | ADDRESSING THE MINIMUM FOR LIFE SAFETY CODE ALONG WITH | | OTHER CODES AS NOTED PREVIOUSLY. | | | | 2) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY A | | NOTICE GIVEN AT THIS TIME. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-01-28 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-01-28 |
Time |
09:50 |
Sent To |
|
|
Notes |
2008-01-28 09:50:50 | ** DENIEDREVIEW ** | | | | | | | | 1) NOTE: PLEASE SEE THE FOLLOWING CODES ARE TO BE | | PLACED ON ELECTRICAL PLANS FOR RELEVANT DESIGN. | | 2004 FBC W/2007 REVISIONS. | | 2005 NFPA-70 2003 NFPA-101 | | | | 2) NOTE: PLEASE SUBMIT ELECTRICAL PLANS SHOWING ANY NEW | | ELECTRICAL LIGHTING AND WIRING METHODS REQUIRED FOR | | EGRESS. | | PLEASE SUBMIT PHOTO-METRICLEVELS FOR NEW EGRESS PATHS | | AND AREAS. PLEASE SEE NFPA-101 7.8.1.3 AND 7.9.2.2. | | PLEASE SEE FAC 61G15-33.004 | | PLEASE SHOW OCCUPANCY OF MEZZ LEVEL AND LIGHTING. | | | | 3) NOTE: PLEASE SEE FBC CHAPTER 13. PLEASE SEE | | 13-415.1.ABC.1.1, .1.2 FOR LIGHTING CONTROLS REQUIRED. | | PLEASE SEE 13-415.2 FOR MAXIMUM LIGHTING PERFORMANCE | | CALCULATIONS. | | | | ** PLEASE KNOW AS THERE WAS NO ELECTRICAL PLANS, NO | | ELECTRICAL DETAILS ETC SUBMITTED FOR REVIEW THERE MAY | | VERY WELL BE NEW COMMENTS ON THE NEXT REVIEW. THERE ARE | | SEVERAL ITEMS WHICH COULD NOT BE REVIEWED AT THIS | | TIME. | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | CONTACTING THIS REVIEWER. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | TWO SETS/FOLDERS/BINDERS ETC. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-04-22 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-04-22 |
Time |
10:37 |
Sent To |
|
|
Notes |
2008-04-22 11:06:01 | *****DENIED***** | | | | THE COMMENTS (NOT MARKED OK) FROM THE PREVIOUS FIRE | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 1.STRUCTURAL CALCULATION COVER SHEET AND MEZZANINE | | SHEET 1 STILL SHOW 100 AS THE SUITE NUMBER.SHOULD BE | | SUITE 1000 | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | AS A GENERAL NOTE | | | | 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.ADD | | AS A GENERAL NOTE | | | | 4.OK | | | | 5.OK | | | | 6.OK | | | | 7.HOW WILL THIS MEZZANINE IMPACT THE EXISTING FIRE | | SPRINKLER AND FIRE ALARM DEVICES.SPRINKLERS ARE | | SHOWN, HOWEVER SPRINKLER PROTECTION NEEDED ABOVE AND | | BELOW THE MEZZANINE.PROVIDE A LAYOUT OF THE FIRE | | ALARM DEVICES IN THE SPACE INCLUDING THE PROPOSED | | MEZZANINE. | | | | 8.OK | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-02-12 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-02-12 |
Time |
15:53 |
Sent To |
|
|
Notes |
2008-02-12 16:52:15 | *****DENIED***** | | | | | | 1. THE CORRECT SUITE NUMBER SHALL BE LISTED AS PART OF | | THE PROJECT SITE ADDRESS. PLEASE SEE THAT SUITE 100 AND | | SUITE 1000 ARE SHOWN ON THE SUBMITTED PLAN SHEETS AND | | STRUCTURAL CALCULATIONS DOCUMENTS. PLEASE | | RECTIFY. | | | | 2. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3. COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 4. PLEASE INDICATE IF THE BUILDING IS TO BE OCCUPIED | | DURING THE SCOPE OF WORK. IF SO, MEANS OF EGRESS AND | | AND REQUIRED FIRE PROTECTION FEATURES ARE TO BE IN | | PLACE AND CONTINUOUSLY MAINTAINED. | | | | 5. PLEASE LIST THE FOLLOWING FOR THE BUILDING: | | OCCUPANCY TYPE, OCCUPANT LOAD, FIRE ALARM AND/OR FIRE | | SPRINKLER DEVICES, AND ANY OTHER PERTINENT | | INFORMATION. | | | | 6. PLEASE PROVIDE A CLEAR REPRENSENTATION OF THE | | MEZZANINE IN RELATION TO THE FLOOR PLAN INCLUDING EXIT | | LIGHTS/DOORS, EMERGENCY LIGHTS, ETC. | | | | 7. HOW WILL THIS MEZZANINE IMPACT THE EXISTING FIRE | | SPRINKLER AND FIRE ALARM DEVICES. | | | | 8. NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | REFERENCED. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER, INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-03-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-31 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-31 |
Time |
14:29 |
Sent To |
|
|
Notes |
2008-03-31 14:31:44 | TO "COMM" BD#27 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-24 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-24 |
Time |
13:18 |
Sent To |
|
|
Notes |
2008-01-24 13:18:26 | TO "COMM" BD#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-02-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-02-12 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-01-15 |
Time |
10:55 |
Sent To |
|
|
Notes |
2008-01-15 10:58:59 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2008-04-01 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-04-01 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-04-01 |
Time |
09:04 |
Sent To |
|
|
Notes |
2008-04-01 09:05:17 | APPROVED FOR 765 SQ. FT. STORAGE MEZZANINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2008-01-16 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-01-16 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-01-16 |
Time |
13:32 |
Sent To |
B |
|
Notes |
2008-01-16 13:36:12 | FAILED | | | | THE PLANS THAT LIST THE MEZZANINE SPECIFICATIONS | | SHALL: | | | | 1) CLEARLY STATE THAT THE MEZZANINE IS FOR STORAGE | | ONLY. | | | | 2) SHOW THE TOTAL MEZZANINE SQ. FT. (I.E. FINISH THE | | DIMENSION CALCULATION). | | | | CONTACT ERIC SCHNEIDER @ 822-1435. |
|
|
|