Plan Review Stops For Permit 07120667 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2008-01-29 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2008-01-29 |
Time |
09:49 |
Sent To |
|
|
Notes |
2008-01-29 09:50:11 | THE SITE ADDRESS FOR THIS BLDG 3 REMAINS AS IT IS AS | | 1019 21ST ST , WEST PALM BEACH, FL 33407. | | | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | CITY OF WEST PALM BEACH | | OFFICE:822-1239 | | FAX: 822-1249 | | E-MAIL:[email protected] |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2008-01-10 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2008-01-10 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2008-01-10 |
Time |
09:32 |
Sent To |
|
|
Notes |
2008-01-10 09:36:26 | ***FAILED*** | | | | SINCE ON THIS PROPERTY FOUR STRUCTURES ARE EXISTING AND | | TWO OF THEM ARE USING A FRACTIONAL SITE ADDRESS ,AN | | ADDRESS CHANGE WILL OCCUR ,THEREFORE TO HAVE THE | | CORRECT SITE ADDRESS ASSIGNED TO EACH OF THE | | STRUCTURES, PLEASE PROVIDE A LOCATION MAP WITH ALL | | EXISTING ADDRESSES TO THIS DEPARTMENT AND AFTER THE | | REVIEWNEW ADDRESSES WILL BE ASSIGNED IN THE CORRECT | | ORDERTO EACH STRUCTURE. | | | | QUESTIONS/COMMENTS | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | CITY OF WEST PALM BEACH | | OFFICE:822-1239 | | FAX: 822-1249 | | E-MAIL:[email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-06-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-06-13 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-06-13 |
Time |
10:25 |
Sent To |
PC |
|
Notes |
2008-06-13 10:41:43 | PERMIT VALUATION UPDATED TO INCLUDE REVISED SCOPE OF | | WORK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-28 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-28 |
Time |
15:41 |
Sent To |
AD |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2008-01-09 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2008-01-09 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2008-01-09 |
Time |
16:52 |
Sent To |
P |
|
Notes |
2008-01-09 16:52:50 | RESIDENTIAL RENOVATION, BUILDING REVIEWCHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1-VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. THE PERMIT VALUATION NEEDS TO BE UPDATED TO | | INCLUDE ALL SCOPE OF WORK TO BE PERFORMED, INCLUDING | | BUILDING, PLUMBING, ELECTRICAL AND MECHANICAL WORK | | SPECIFIED ON PERMIT APPLICATION AND PLANS. SEC. | | 108.3 CITY AMENDMENTS OT FBC 2004. (REPEAT COMMENT). | | | | 2-PROVIDE ONLY THE INFORMATIONTHAT IS RELEVANT TO | | THE SCOPE OF WORK TO BE PERFORMED.IF NOT WORK IS DONE | | ON EXTERIOR WALLS, THEN EXTERIOR ELEVATIONS AND TYPICAL | | WALL SECTIONS ARE NOT REQUIRED.THIS CONFUSES THE | | SCOPE OF WORK TO BE PERFORMED ANDTOTAL PERMIT | | VALUATION.SEC. 106.1.1 CITY AMENDMENTS TO FBC 2004. | | | | 3- ALL DRAWINGS TO HAVE THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN.SOME DRAWINGS ARE | | MISSING THE SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | DESIGN.SEC. 106.1.3 CITY AMENDMENTS TO FBC 2004. | | | | 4-DESIGNER OF RECORDTO REVIEW AND APPROVE IN | | WRITING ALL PRODUCT APPROVALS AS REQUIRED BY SEC. | | 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | 5- ENERGY CALCULATIONS: REVISE ITEM #10(A)AND TABLE | | 6C-1.NEED R-30AS THE MINIMUM INSULATION. ALSO, | | REVISE MINIMUM INSULATION FOR DUCT. SEE TABLE 6C-1 AND | | COMMENTS BY MECHANICAL PLAN REVIEWER. | | | | 6-ACCORDING TO PERMIT APPLICATION SCOPE OF WORK | | INCLUDES ONLY ONE WINDOW TO BE REPLACED.SEC. 507.3 | | EXCEPTION #1 DOESN'T REQUIRE SHUTTERS IFLESS THAN 25% | | OF THEHOUSE GLASS AREA IS REPLACED. | | NOTE:IS HIGHLY RECOMMENDED TO PROTECT ALL OPENINGS, | | BUT IS NOT REQUIRED FOR THE SCOPE OF WORKSTIPULATED | | IN THE PERMIT APPLICATION. | | | | 7- PLEASE COORDINATE WITH ZONING REGARDING LOCATION OF | | A/C UNITS AND REQUIRED SETBACKS. CALL CHRIS HOOPS AT | | 805-6720 FOR REQUIRED INFORMATION. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-04-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-04-30 |
Time |
12:54 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-04-30 |
Time |
12:40 |
Sent To |
B |
|
Notes |
2008-04-30 12:53:54 | | | | | | | | | | | | | PROVISO | | | | THE PLANS ARE BEGINNING TO LACK CLARITY DUE TO NOTES | | AND INFORMATION BEING COPIED. IF THIS PLAN IS SUBMITTED | | FOR REVISION IN THE FUTURE, SEPARATE THE ELECTRICAL | | PLAN FROM THE ARCHITECTURAL AND REMOVE ALL CLOUDS | | EXCEPT THE ONES PERTAINING TO THAT REVISION. 106.1.3 | | FBC AS AMENDED. SEE REDLINED RECEPTACLES AS REQUIRED | | PER 210.52(A)(1). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-25 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-25 |
Time |
06:46 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2008-01-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-03 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-03 |
Time |
09:30 |
Sent To |
M |
|
Notes |
2008-01-03 09:48:55 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE NOTE FOR THE FEEDER (RISER DIAGRAM) INDICATES | | "MAIN LUG", THE PANEL ON THE RISER INDICATES "MAIN | | BREAKER". CORRELATE SO THE DESIGNERS INTENTION IS | | CLEAR,106.1.1 FBC AS AMENDED. | | | | 2} THERE ARE DISPOSAL AND DISHWASHER BREAKERS IN THE | | PANEL WITH NO LOADS SHOWN FOR CALCULATIONS. ALL LOADS | | MUST BE LISTED AT NAMEPLATE RATING . 220.83 NEC.ALSO | | NOTE: THE BATH GFI CIRCUIT IS PART OT THE GENERAL | | LIGHTING LOAD AND DOES NOT NEED TO BE RECALAULATED, | | (SEE 1500 VA). | | | | 3} THE A/C LOAD ON THE PANEL SCHEDULE NOW LISTED AT | | 10000VA, AND THE MECHANICAL PLAN AT 7500VA, CORRELATE | | SAME. | | | | 4} INDICATE A DISCONNECTING MEANS FOR THE WATER HEATER. | | SEE 422.16 NEC FOR CORD AND PLUG RESTRICTIONS, AND | | 422.31(B) FOR HARDWIRE REQUIREMENTS. | | | | 5} A RECEPTACLE IS REQUIRED FOR SPACING REQUIREMENT | | 210.52(A)(1), IN THE DINING ROOM ON THE A/C WALL. | | | | 6} NFPA-72 REQUIRES ALARMS OR DETECTORS WITHIN 20 FEET | | OF COOKING APPLIANCES BE SILENCING OR PHOTOELECTRIC. | | SEE 11.8.3.5(4). | | | | 7} R313.1 SMOKE ALARMS. | | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING | | LOCATIONS: | | 1. IN EACH SLEEPING ROOM. | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | VICINITY OF THE BEDROOMS. | | THE BACK BEDROOM DOES NOT HAE ONE "OUTSIDE". | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-06-11 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-06-11 |
Time |
16:09 |
Sent To |
B |
|
Notes |
2008-06-11 16:10:15 | TO "JGOMEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-04-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-29 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-29 |
Time |
12:03 |
Sent To |
E |
|
Notes |
2008-04-29 12:03:37 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2008-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-18 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-18 |
Time |
10:15 |
Sent To |
E |
|
Notes |
2008-01-18 10:15:34 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-10 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-31 |
Time |
12:07 |
Sent To |
E |
|
Notes |
2007-12-31 12:07:46 | TO BILL TROBAUGHS DESK |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-05-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-01 |
Time |
13:53 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-05-01 |
Time |
13:53 |
Sent To |
|
|
Notes |
2008-05-01 13:53:41 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-25 |
Time |
16:12 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-01-25 |
Time |
16:12 |
Sent To |
P |
|
Notes |
2008-01-25 16:12:39 | *** PROVISO *** | | 1) PROVIDE RETURN AIR TO ALL REQUIRED SPACES AND BACK | | TO AIR HANDLER, SEE 2004 FBC/R M1602.4. THE RETURN AIR | | MAY NOT COME FROM THE KITCHEN, SEE 2004 FBC/R M1602.2. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2008-01-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-03 |
Time |
12:09 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2008-01-03 |
Time |
12:09 |
Sent To |
P |
|
Notes |
2008-01-03 12:11:06 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | *** DENIED *** | | | | 1) ENERGY CALCULATIONS LINE 10A IS SHOWING R-19 FOR | | UNDER ATTIC, TABLE 6C-1 ON BACK OF ENERGY CALCULATIONS | | STATES MINIMUM INSULATION FOR UNDER ATTIC IS R-30, SEE | | 2004 FBC 13-604.1.C.1, PLEASE CORRECT. | | | | 2) SHOW ATTIC INSULATION AND R. VALUE ON BUILDING PLAN | | PAGE 2, SEE 2004 FBC 13-604.1.C.1. | | | | 4) PROVIDE RETURN AIR TO BEDROOMS, SEE 2004 FBC/R | | M1602.4. | | | | 5) MECHANICAL PLAN SHOWS A 10" AND A12" DUCT GOING TO | | THE MIXING BOX NEAR THE AIR HANDLER, THIS APPEARS TO BE | | AN ERROR (SEE YELLOW HIGH LIGHT ON MECH. PLAN), SEE | | 2004 FBC 106.1.1, PLEASE CORRECT. | | | | 6) SHOW IN THE A/C EQUIPMENT SCHEDULE THE MODEL NUMBERS | | FOR THE AIR HANDLER AND CONDENSER UNIT, ALSO THE TOTAL | | BTU'S, SEE 2004 WPB AMEND. 106.3.5.4 (10). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2008-04-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-04-30 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-04-30 |
Time |
16:43 |
Sent To |
M |
|
Notes |
2008-04-30 16:45:41 | REVISION SHEET 1: "OK" DELETED PLUMBING FIXTURE LAYOUT | | FROM MECHANICAL PLANS, PLUMBING FIXTURE LAYOUT PER | | APPROVED FLOOR PLAN. RELOCATED WATER HEATER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-28 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-28 |
Time |
08:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2008-01-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-04 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-04 |
Time |
09:34 |
Sent To |
B |
|
Notes |
2008-01-04 09:36:04 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | PLUMBING PLAN REVIEW: | | DENIED: | | | | 1. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING | | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE | | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE | | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER | | SECTION *106.3.4.3. | | IF THE DESIGN PROFESSIONAL IS AN ARCHITECT OR | | ENGINEER, THEN HE OR SHE SHALL AFFIX HIS OR HER | | OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, PER | | FLORIDA STATUTES 481 AND 471 RESPECTIVELY. **SHEETS #2 | | AND #3 ARE NOT SIGNED ON BOTH SETS. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | |
|
|